[{"data":1,"prerenderedAt":1308},["ShallowReactive",2],{"subject-water-chemical":3},{"meta":4,"subjectMeta":21,"years":26,"essays":1286},{"subject":5,"slug":6,"count":7,"explained":8,"indexable":8,"essayCount":9,"sessions":10},"水與化學系統消防安全設備概要","water-chemical",399,242,20,[11,12,13,14,15,16,17,18,19,20],"106-1","107-1","108-1","109-1","110-1","111-1","112-1","113-1","114-1","115-1",{"name":5,"shortName":22,"slug":6,"fullName":5,"kicker":23,"tagline":24,"hint":25},"水與化學系統","水與化學系統 · Water & Chemical","室內外消防栓、自動撒水、水霧泡沫,加上二氧化碳、乾粉與惰性氣體滅火設備——法定數值與檢修判定的重災區。","水系統抓消防栓放水壓力與放水量(室內 1.7、室外 2.5 kgf\u002Fcm² 等門檻)、撒水頭配置與撒水頭迴水板高度、水源容量計算;化學系統抓二氧化碳\u002F乾粉\u002F惰性氣體的設計濃度、藥劑量計算與放射時間,並注意《檢修基準》的性能檢查與判定值。計算題全 corpus 61 題,次於火災學。",[27,189,313,435,557,677,799,921,1043,1164],{"ys":20,"list":28},[29,35,39,44,49,53,57,61,65,70,74,78,82,86,90,94,98,102,106,110,113,117,121,125,129,133,137,141,145,149,153,157,161,165,169,173,177,181,185],{"webId":30,"number":31,"stem":32,"answer":33,"indexable":34},"fire-115-1-water-chemical-001",1,"有關消防幫浦性能試驗，下列敘述何者錯誤？","C",false,{"webId":36,"number":37,"stem":38,"answer":33,"indexable":34},"fire-115-1-water-chemical-002",2,"某大樓設有室內消防栓設備，使用第一種室內消防栓，若該室內消防栓之瞄子壓力經檢測為 4 kg\u002Fcm2，試問在這種壓力下，其放水…",{"webId":40,"number":41,"stem":42,"answer":43,"indexable":34},"fire-115-1-water-chemical-003",3,"室內消防栓設備之消防立管管系竣工時，應做加壓試驗，試驗壓力不得小於加壓送水裝置全閉揚程 X 倍以上之水壓。試驗壓力以繼續維持…","B",{"webId":45,"number":46,"stem":47,"answer":48,"indexable":34},"fire-115-1-water-chemical-004",4,"有關第二種室內消防栓設置之規定，下列敘述何者正確？","D",{"webId":50,"number":51,"stem":52,"answer":33,"indexable":34},"fire-115-1-water-chemical-005",5,"室內消防栓瞄子放水壓力超過 X Mpa 時，室外消防栓瞄子放水壓力超過 Y Mpa 時，應採取有效之減壓措施。X、Y 值各為…",{"webId":54,"number":55,"stem":56,"answer":33,"indexable":34},"fire-115-1-water-chemical-006",6,"應設置室外消防栓設備場所，同一建築基地內有二棟以上木造或其他易燃構造建築物時，建築物間外牆與中心線水平距離第一層在 X 公尺…",{"webId":58,"number":59,"stem":60,"answer":48,"indexable":34},"fire-115-1-water-chemical-007",7,"儲存柴油（閃火點≧65℃）之作業場所，依各類場所消防安全設備設置標準規定，建築物及儲存場所之第一層及第二層樓地板面積合計在多…",{"webId":62,"number":63,"stem":64,"answer":43,"indexable":34},"fire-115-1-water-chemical-008",8,"某公共危險物品場所設置室外消防栓設備，在裝置全部消防栓數量 5 支時，其所需之水源容量至少應為多少立方公尺以上？",{"webId":66,"number":67,"stem":68,"answer":69,"indexable":34},"fire-115-1-water-chemical-009",9,"有關自動撒水設備之設置，下列敘述何者正確？","A",{"webId":71,"number":72,"stem":73,"answer":48,"indexable":34},"fire-115-1-water-chemical-010",10,"有關撒水頭之位置裝置規定，下列敘述何者正確？",{"webId":75,"number":76,"stem":77,"answer":33,"indexable":34},"fire-115-1-water-chemical-011",11,"裝置於舞臺之開放式自動撒水設備，下列敘述何者正確？",{"webId":79,"number":80,"stem":81,"answer":48,"indexable":34},"fire-115-1-water-chemical-012",12,"開放式自動撒水設備之自動及手動啟動裝置，下列敘述何者正確？",{"webId":83,"number":84,"stem":85,"answer":69,"indexable":34},"fire-115-1-water-chemical-013",13,"某一地下建築物，設置密閉式一般反應型撒水頭之自動撒水設備時，依各類場所消防安全設備設置標準規定，其水源容量不得小於 X 個撒…",{"webId":87,"number":88,"stem":89,"answer":33,"indexable":34},"fire-115-1-water-chemical-014",14,"密閉乾式或預動式自動撒水設備之規定，下列敘述何者錯誤？",{"webId":91,"number":92,"stem":93,"answer":48,"indexable":34},"fire-115-1-water-chemical-015",15,"公共危險物品等場所設置自動撒水設備時，使用密閉式撒水頭其水源容量，應在設置 X 個撒水頭繼續放水 Y 分鐘之水量以上。X、Y…",{"webId":95,"number":96,"stem":97,"answer":69,"indexable":34},"fire-115-1-water-chemical-016",16,"水霧滅火設備之水霧噴頭及配管與具有 9 KV 之高壓電器設備，最低應保持多少公厘之距離，以避免導電造成意外？",{"webId":99,"number":100,"stem":101,"answer":33,"indexable":34},"fire-115-1-water-chemical-017",17,"有關水霧滅火設備之規定，下列敘述何者正確？",{"webId":103,"number":104,"stem":105,"answer":48,"indexable":34},"fire-115-1-water-chemical-018",18,"水霧滅火設備之加壓送水裝置使用消防幫浦時，用於防護電氣設備者，每一個水霧噴頭壓力依規定均應達到多少 kgf\u002Fcm2 以上？",{"webId":107,"number":108,"stem":109,"answer":33,"indexable":34},"fire-115-1-water-chemical-019",19,"泡沫試料淨重為 200 g，還原數值如下，則 25%還原時間為何？時間（分） 0 0.5 1 1.5 2 2.5 3 還原量…",{"webId":111,"number":9,"stem":112,"answer":69,"indexable":34},"fire-115-1-water-chemical-020","有關泡沫頭之規定，下列敘述何者錯誤？",{"webId":114,"number":115,"stem":116,"answer":33,"indexable":34},"fire-115-1-water-chemical-021",21,"高發泡放出口在全區放射防護區域內，樓地板面積每多少平方公尺應至少設置 1 個，且能有效放射至該區域，並附設泡沫放出停止裝置？",{"webId":118,"number":119,"stem":120,"answer":33,"indexable":34},"fire-115-1-water-chemical-022",22,"對於泡沫滅火設備構造與機能，下列敘述何者錯誤？",{"webId":122,"number":123,"stem":124,"answer":33,"indexable":34},"fire-115-1-water-chemical-023",23,"消防搶救上所需之連結送水管，應為專用，其立管管徑在一百公厘以上；但考量耐壓、經濟等因素，得與室內消防栓共用立管，其法規判斷的…",{"webId":126,"number":127,"stem":128,"answer":69,"indexable":34},"fire-115-1-water-chemical-024",24,"任一消防專用蓄水池至建築物各部分之水平距離應在 A 公尺以下，且其有效水量在 B 立方公尺以上；並設於消防車能接近至其 C …",{"webId":130,"number":131,"stem":132,"answer":69,"indexable":34},"fire-115-1-water-chemical-025",25,"下列場所何者應設置滅火器？",{"webId":134,"number":135,"stem":136,"answer":33,"indexable":34},"fire-115-1-water-chemical-026",26,"乾粉滅火設備之緊急電源應為發電機設備或蓄電池設備，其容量應能使該設備有效動作多少分鐘以上？",{"webId":138,"number":139,"stem":140,"answer":33,"indexable":34},"fire-115-1-water-chemical-027",27,"下列何者不是可燃性高壓氣體製造場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽之防護設備？",{"webId":142,"number":143,"stem":144,"answer":48,"indexable":34},"fire-115-1-water-chemical-028",28,"鹵化烴滅火設備之防護區域竣工時，為維持放射藥劑濃度之有效性，需進行下列那一項測試程序？",{"webId":146,"number":147,"stem":148,"answer":69,"indexable":34},"fire-115-1-water-chemical-029",29,"鹵化烴滅火設備使用氣體啟動者，有關設置之規定，下列敘述何者正確？",{"webId":150,"number":151,"stem":152,"answer":33,"indexable":34},"fire-115-1-water-chemical-030",30,"某空間採用全區放射方式之第一種乾粉滅火設備（主成份為碳酸氫鈉）進行防護，則每立方公尺防護區域所需滅火藥劑量為多少 kg\u002Fm3…",{"webId":154,"number":155,"stem":156,"answer":43,"indexable":34},"fire-115-1-water-chemical-031",31,"在第三類公共危險物品之禁水性物質之作業場所設置消防安全設備時，下列何種滅火藥劑不宜選用？",{"webId":158,"number":159,"stem":160,"answer":33,"indexable":34},"fire-115-1-water-chemical-032",32,"有關二氧化碳滅火設備之放射時間，下列敘述何者正確？",{"webId":162,"number":163,"stem":164,"answer":48,"indexable":34},"fire-115-1-water-chemical-033",33,"對有 36 支高壓鋼瓶全區放射之二氧化碳滅火系統進行綜合檢查，放射試驗所需之藥劑量，應為多少支鋼瓶？",{"webId":166,"number":167,"stem":168,"answer":48,"indexable":34},"fire-115-1-water-chemical-034",34,"第五種滅火設備除滅火器外之其他設備，有關核算滅火效能值之規定，下列敘述何者正確？",{"webId":170,"number":171,"stem":172,"answer":69,"indexable":34},"fire-115-1-water-chemical-035",35,"在常時有人之場所，使用藥劑之最高設計濃度，下列敘述何者正確？",{"webId":174,"number":175,"stem":176,"answer":48,"indexable":34},"fire-115-1-water-chemical-037",37,"有關惰性氣體滅火設備之藥劑設計濃度之規定，下列敘述何者錯誤？",{"webId":178,"number":179,"stem":180,"answer":48,"indexable":34},"fire-115-1-water-chemical-038",38,"可燃性高壓氣體製造、儲存或處理場所，樓地板面積為三百三十平方公尺，設置之滅火器至少應多少具以上？",{"webId":182,"number":183,"stem":184,"answer":48,"indexable":34},"fire-115-1-water-chemical-039",39,"關於乾粉滅火設備加、蓄壓用氣體量，下列敘述何者正確？",{"webId":186,"number":187,"stem":188,"answer":43,"indexable":34},"fire-115-1-water-chemical-040",40,"下列何種滅火劑使用於金屬火災時，沒有「與金屬產生化學反應而衍生危害物質」的可能？",{"ys":19,"list":190},[191,194,197,200,204,207,210,213,216,219,222,225,228,231,234,237,240,243,246,249,252,255,258,261,264,267,270,273,276,279,282,285,288,291,294,297,301,304,307,310],{"webId":192,"number":31,"stem":193,"answer":43,"indexable":34},"fire-114-1-water-chemical-001","因應老人福利機構人力短缺及照護人員多為女性之境況，以設置單人易於操作之第二種室內消防栓較佳。有關第二種室內消防栓之設置規定，…",{"webId":195,"number":37,"stem":196,"answer":43,"indexable":34},"fire-114-1-water-chemical-002","依各類場所消防安全設備設置標準規定，惰性氣體滅火設備於常時有人之場所，其藥劑最高設計濃度以多少為限？",{"webId":198,"number":41,"stem":199,"answer":48,"indexable":34},"fire-114-1-water-chemical-003","依各類場所消防安全設備設置標準規定，惰性氣體滅火設備之藥劑種類及容量比，下列何者錯誤？",{"webId":201,"number":46,"stem":202,"answer":43,"indexable":203},"fire-114-1-water-chemical-004","依各類場所消防安全設備設置標準規定，鹵化烴滅火設備，蓄壓式儲存容器儲存 HFC-227ea、 FK-5-1-12 之儲存壓力…",true,{"webId":205,"number":51,"stem":206,"answer":69,"indexable":34},"fire-114-1-water-chemical-005","惰性氣體及鹵化烴滅火設備之防護區域竣工時，應做防護區域完整性測試，X 分鐘內之氣體洩漏量使滅火藥劑維持在設計濃度 Y %以上…",{"webId":208,"number":55,"stem":209,"answer":69,"indexable":34},"fire-114-1-water-chemical-006","依各類場所消防安全設備設置標準規定，鹵化烴滅火設備於常時有人之場所，其藥劑最高設計濃度，HFC-23：X %、HFC-227…",{"webId":211,"number":59,"stem":212,"answer":33,"indexable":34},"fire-114-1-water-chemical-007","依各類場所消防安全設備設置標準規定，有關全區放射方式化學滅火設備之噴頭放射壓力規定，下列何者錯誤？",{"webId":214,"number":63,"stem":215,"answer":48,"indexable":34},"fire-114-1-water-chemical-008","乾粉滅火設備配管設置，最低配管與最高配管間，落差在 X 公尺以下，且配管任一部分與彎曲部分之距離應為管徑 Y 倍以上，則 X…",{"webId":217,"number":67,"stem":218,"answer":48,"indexable":34},"fire-114-1-water-chemical-009","平時供不特定人員使用之電腦室，樓地板面積在 200 平方公尺以上，得選擇下列何種滅火設備設置？①二氧化碳 ②惰性氣體 ③鹵化…",{"webId":220,"number":72,"stem":221,"answer":33,"indexable":34},"fire-114-1-water-chemical-010","針對滅火器實施外觀檢查，有關滅火器設置間距之判定方法，下列敘述何者錯誤？",{"webId":223,"number":76,"stem":224,"answer":43,"indexable":34},"fire-114-1-water-chemical-011","依滅火器認可基準規定，某種滅火器滅火效能值標示 B-20，該滅火器實施滅火效能值之第二種滅火試驗方式，下列敘述何者錯誤？",{"webId":226,"number":80,"stem":227,"answer":33,"indexable":34},"fire-114-1-water-chemical-012","某場所設置消防專用蓄水池採機械方式引水，且依規定設有 2 個採水口。若距離蓄水池最遠端之採水口配管摩擦損失水頭為 5 公尺，…",{"webId":229,"number":84,"stem":230,"answer":33,"indexable":34},"fire-114-1-water-chemical-013","連結送水管之出水口，應設於建築物第 X 層以上各層樓梯間或緊急昇降機間，且各層任一點至出水口之水平距離應在 Y 公尺以下。出…",{"webId":232,"number":88,"stem":233,"answer":69,"indexable":34},"fire-114-1-water-chemical-014","因應電動車的普及，室內停車空間設計得採用自動撒水設備，下列敘述何者錯誤？",{"webId":235,"number":92,"stem":236,"answer":69,"indexable":34},"fire-114-1-water-chemical-015","依各類場所消防安全設備設置標準規定，儲存硫磺之室內、外儲槽場所，屬顯著滅火困難場所，設置第三種滅火設備應選擇下列何種滅火設備…",{"webId":238,"number":96,"stem":239,"answer":48,"indexable":34},"fire-114-1-water-chemical-016","水霧滅火設備之放射區域有二區以上時，其主管管徑不得小於 X 毫米，其水源容量應保持在 Y 立方公尺以上。則 X+Y 為多少？",{"webId":241,"number":100,"stem":242,"answer":33,"indexable":34},"fire-114-1-water-chemical-017","依水道連結型自動撒水設備設置基準規定，有關使用獨立水箱式類型之水道連結型自動撒水設備，下列敘述何者正確？",{"webId":244,"number":104,"stem":245,"answer":69,"indexable":34},"fire-114-1-water-chemical-018","公共危險物品等場所達顯著滅火困難者，設置第一種滅火設備室內消防栓，今於裝置消防栓最多之最高樓層進行綜合檢查放水試驗，則消防栓…",{"webId":247,"number":108,"stem":248,"answer":43,"indexable":34},"fire-114-1-water-chemical-019","有關連結送水管之敘述，下列何者正確？",{"webId":250,"number":9,"stem":251,"answer":43,"indexable":34},"fire-114-1-water-chemical-020","建築物高度超過多少公尺時，其連結送水管應採用濕式？",{"webId":253,"number":115,"stem":254,"answer":69,"indexable":34},"fire-114-1-water-chemical-021","一般場所設置室外消防栓時，瞄子放水壓力超過每平方公分多少公斤時，應採減壓設施？",{"webId":256,"number":119,"stem":257,"answer":48,"indexable":34},"fire-114-1-water-chemical-022","消防專用蓄水池採機械方式引水，若其落差 10 公尺，配管摩擦損失水頭 5 公尺，則其加壓送水裝置幫浦全揚程應為多少公尺以上？",{"webId":259,"number":123,"stem":260,"answer":69,"indexable":34},"fire-114-1-water-chemical-023","設置室外消防栓之場所，應於其 X 公尺內附設水帶箱，於其 Y 公尺內保持空曠，則 X 與 Y 各為多少？",{"webId":262,"number":127,"stem":263,"answer":33,"indexable":34},"fire-114-1-water-chemical-024","依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，消防幫浦出水量在額定出水量時，在其性能曲線上之全揚程必須達到額定揚程之多少？",{"webId":265,"number":131,"stem":266,"answer":43,"indexable":34},"fire-114-1-water-chemical-025","飛機庫等場所設置泡水噴頭，其噴頭放射量應在每分鐘多少公升以上？",{"webId":268,"number":135,"stem":269,"answer":43,"indexable":34},"fire-114-1-water-chemical-026","汽車修理廠、室內停車空間及昇降機械式停車場，設置自動撒水設備時，任一點至撒水頭之水平距離在多少公尺以下？",{"webId":271,"number":139,"stem":272,"answer":43,"indexable":34},"fire-114-1-water-chemical-027","設置密閉式撒水頭場所平時最高周圍溫度約為攝氏 50 度，應選擇下列何種標示溫度之撒水頭？",{"webId":274,"number":143,"stem":275,"answer":43,"indexable":34},"fire-114-1-water-chemical-028","密閉乾式撒水頭在撒水頭動作後，流水檢知裝置應在多少時間內，使撒水頭放水？",{"webId":277,"number":147,"stem":278,"answer":69,"indexable":34},"fire-114-1-water-chemical-029","發電機室設置水霧滅火設備時，其出水壓力應在每平方公分多少公斤以上？",{"webId":280,"number":151,"stem":281,"answer":69,"indexable":34},"fire-114-1-water-chemical-030","中央主管機關認定儲存大量可燃物之場所天花板高度超過 X 公尺，或其他場所天花板高度超過 Y 公尺者，應採用放水型撒水頭，則 …",{"webId":283,"number":155,"stem":284,"answer":33,"indexable":34},"fire-114-1-water-chemical-031","二氧化碳滅火設備採移動放射方式，每一具噴射瞄子所需滅火藥劑量在 X 公斤以上，瞄子之藥劑放射量在溫度攝氏 20 度時，應在每…",{"webId":286,"number":159,"stem":287,"answer":69,"indexable":34},"fire-114-1-water-chemical-032","密閉式撒水設備進行綜合檢查時，末端查驗管之放水壓力合格判定標準為何？",{"webId":289,"number":163,"stem":290,"answer":43,"indexable":34},"fire-114-1-water-chemical-033","鹵化烴滅火設備進行性能檢查時，氣壓式選擇閥開放裝置以試驗用二氧化碳容器自操作管連接部加壓，若試驗用容器內容積為 1 公升，則…",{"webId":292,"number":167,"stem":293,"answer":43,"indexable":34},"fire-114-1-water-chemical-034","依各類場所消防安全設備設置標準規定，有關高架儲存倉庫設置自動撒水設備，下列敘述何者錯誤？",{"webId":295,"number":171,"stem":296,"answer":69,"indexable":34},"fire-114-1-water-chemical-035","有關乾粉滅火設備加壓或蓄壓氣體之規定，下列敘述何者正確？",{"webId":298,"number":299,"stem":300,"answer":43,"indexable":34},"fire-114-1-water-chemical-036",36,"惰性氣體滅火設備之防護區域竣工時，應做防護區域完整性測試，10 分鐘內之氣體洩漏量使滅火藥劑維持在設計濃度多少以上者為合格？",{"webId":302,"number":175,"stem":303,"answer":48,"indexable":34},"fire-114-1-water-chemical-037","20 型 ABC 乾粉滅火器總重約 10 公斤，當進行外觀檢查之設置場所檢查時，滅火器本體上端與樓地板之距離合格判定標準為何…",{"webId":305,"number":179,"stem":306,"answer":43,"indexable":34},"fire-114-1-water-chemical-038","有關二氧化碳及惰性氣體滅火設備手動啟動裝置設置之規定，下列敘述何者正確？",{"webId":308,"number":183,"stem":309,"answer":33,"indexable":34},"fire-114-1-water-chemical-039","室內停車空間或汽車修理廠等場所設置泡沫滅火設備，樓地板面積每多少平方公尺應設置一個泡沫噴頭？",{"webId":311,"number":187,"stem":312,"answer":69,"indexable":34},"fire-114-1-water-chemical-040","有關惰性氣體滅火設備噴頭設置之規定，下列敘述何者正確？",{"ys":18,"list":314},[315,318,321,324,327,330,333,336,339,342,345,348,351,354,357,360,363,366,369,372,375,378,381,384,387,390,393,396,399,402,405,408,411,414,417,420,423,426,429,432],{"webId":316,"number":31,"stem":317,"answer":69,"indexable":34},"fire-113-1-water-chemical-001","有關消防安全設備水源容量之放水時間，依據各類場所消防安全設備設置標準規定，下列敘述何者錯誤？",{"webId":319,"number":37,"stem":320,"answer":33,"indexable":34},"fire-113-1-water-chemical-002","室內停車空間設置水霧滅火設備，依據各類場所消防安全設備設置標準規定，下列敘述何者錯誤？",{"webId":322,"number":41,"stem":323,"answer":48,"indexable":34},"fire-113-1-water-chemical-003","公共危險物品場所設置泡沫滅火設備，依據各類場所消防安全設備設置標準規定，下列敘述何者錯誤？",{"webId":325,"number":46,"stem":326,"answer":33,"indexable":34},"fire-113-1-water-chemical-004","有關連結送水管設備測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":328,"number":51,"stem":329,"answer":48,"indexable":34},"fire-113-1-water-chemical-005","廚房設置簡易自動滅火設備，依據各類場所消防安全設備設置標準規定，下列敘述何者錯誤？",{"webId":331,"number":55,"stem":332,"answer":33,"indexable":34},"fire-113-1-water-chemical-006","建築物樓設置消防專用蓄水池，依據各類場所消防安全設備設置標準規定，下列敘述何者錯誤？",{"webId":334,"number":59,"stem":335,"answer":43,"indexable":34},"fire-113-1-water-chemical-007","消防水帶用快速接頭之構造，依據消防水帶用快速接頭認可基準規定，下列敘述何者錯誤？",{"webId":337,"number":63,"stem":338,"answer":33,"indexable":34},"fire-113-1-water-chemical-008","有關幫浦之形狀、構造部分，依據消防幫浦認可基準規定，下列敘述何者錯誤？",{"webId":340,"number":67,"stem":341,"answer":69,"indexable":34},"fire-113-1-water-chemical-009","高度危險工作場所設置室外消防栓進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",{"webId":343,"number":72,"stem":344,"answer":69,"indexable":34},"fire-113-1-water-chemical-010","有關室內消防栓測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":346,"number":76,"stem":347,"answer":43,"indexable":34},"fire-113-1-water-chemical-011","室內消防栓進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",{"webId":349,"number":80,"stem":350,"answer":48,"indexable":34},"fire-113-1-water-chemical-012","自動撒水設備進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",{"webId":352,"number":84,"stem":353,"answer":43,"indexable":34},"fire-113-1-water-chemical-013","水道連結型自動撒水設備進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",{"webId":355,"number":88,"stem":356,"answer":33,"indexable":34},"fire-113-1-water-chemical-014","依據消防安全設備及必要檢修項目檢修基準，於檢查類似醫院之場所時，因切換成緊急電源可能會造成困擾時，得使用常用電源檢查，下列消…",{"webId":358,"number":92,"stem":359,"answer":43,"indexable":34},"fire-113-1-water-chemical-015","有關滅火藥劑每公斤核算空氣量或氮氣量，依據惰性氣體與鹵化烴滅火設備之綜合檢查，下列何者與消防安全設備及必要檢修項目檢修基準規…",{"webId":361,"number":96,"stem":362,"answer":69,"indexable":34},"fire-113-1-water-chemical-016","有關自動撒水設備測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":364,"number":100,"stem":365,"answer":43,"indexable":34},"fire-113-1-water-chemical-017","有關冷卻撒水設備測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":367,"number":104,"stem":368,"answer":48,"indexable":34},"fire-113-1-water-chemical-018","有關泡沫滅火設備泡沫放射試驗判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":370,"number":108,"stem":371,"answer":48,"indexable":34},"fire-113-1-water-chemical-019","關於水帶試驗，下列敘述何者錯誤？",{"webId":373,"number":9,"stem":374,"answer":69,"indexable":34},"fire-113-1-water-chemical-020","有關水道連結型自動撒水設備，下列敘述何者錯誤？",{"webId":376,"number":115,"stem":377,"answer":33,"indexable":34},"fire-113-1-water-chemical-021","密閉式撒水頭之標示溫度，下列何者適用於最高周圍溫度在 39℃以上 64℃未滿之場所？",{"webId":379,"number":119,"stem":380,"answer":43,"indexable":34},"fire-113-1-water-chemical-022","下列場所何者得設置水霧滅火設備？",{"webId":382,"number":123,"stem":383,"answer":69,"indexable":34},"fire-113-1-water-chemical-023","有關停車空間泡沫瞄子綜合試驗，下列敘述何者正確？",{"webId":385,"number":127,"stem":386,"answer":48,"indexable":34},"fire-113-1-water-chemical-024","若同一樓層設 2 個泡沫消防栓箱時，消防幫浦出水量應在每分鐘多少公升以上？",{"webId":388,"number":131,"stem":389,"answer":48,"indexable":34},"fire-113-1-water-chemical-025","有一建築物樓高 40 m，總樓地板面積 30000 m2，其消防專用蓄水池之有效水量規定要多少立方公尺以上？",{"webId":391,"number":135,"stem":392,"answer":69,"indexable":34},"fire-113-1-water-chemical-026","設於外浮頂式儲槽之泡沫放出口為？",{"webId":394,"number":139,"stem":395,"answer":48,"indexable":34},"fire-113-1-water-chemical-027","公共危險物品等場所設置之室內消防栓設備，應符合下列何者規定？",{"webId":397,"number":143,"stem":398,"answer":43,"indexable":34},"fire-113-1-water-chemical-028","下列場所之消防安全設備設置何者錯誤？",{"webId":400,"number":147,"stem":401,"answer":69,"indexable":34},"fire-113-1-water-chemical-029","有關流水檢知裝置之構造，依據流水檢知裝置認可基準規定，下列敘述何者錯誤？",{"webId":403,"number":151,"stem":404,"answer":69,"indexable":34},"fire-113-1-water-chemical-030","鹵化烴滅火設備全區放射綜合檢查時，檢查方法、判定方法及注意事項，下列何者錯誤？",{"webId":406,"number":155,"stem":407,"answer":33,"indexable":34},"fire-113-1-water-chemical-031","依各類場所消防安全設備設置標準規定，二氧化碳滅火設備使用氣體啟動者，下列敘述何者錯誤？",{"webId":409,"number":159,"stem":410,"answer":43,"indexable":34},"fire-113-1-water-chemical-032","某電信機房使用二氧化碳滅火系統，其配管規定，下列敘述何者錯誤？",{"webId":412,"number":163,"stem":413,"answer":33,"indexable":34},"fire-113-1-water-chemical-033","某加油站附設加氣站，其滅火器設置應符合之規定，下列敘述何者錯誤？",{"webId":415,"number":167,"stem":416,"answer":33,"indexable":34},"fire-113-1-water-chemical-034","蓄壓式鹵化烴滅火藥劑儲存容器使用水平液面計之方法進行滅火藥劑量性能檢查，下列敘述何者錯誤？",{"webId":418,"number":171,"stem":419,"answer":48,"indexable":34},"fire-113-1-water-chemical-035","惰性氣體進行高壓式全區放射綜合檢查，下列敘述何者錯誤？",{"webId":421,"number":299,"stem":422,"answer":48,"indexable":34},"fire-113-1-water-chemical-036","有關室外消防栓測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":424,"number":175,"stem":425,"answer":69,"indexable":34},"fire-113-1-water-chemical-037","加壓式乾粉滅火設備應設壓力調整裝置，可調整壓力至多少 Mpa 以下？",{"webId":427,"number":179,"stem":428,"answer":43,"indexable":34},"fire-113-1-water-chemical-038","依各類場所消防安全設備設置標準之規定，下列何場所得免設滅火器？",{"webId":430,"number":183,"stem":431,"answer":33,"indexable":34},"fire-113-1-water-chemical-039","某一工廠儲存鹼金屬過氧化物，滅火藥劑適用下列何者？",{"webId":433,"number":187,"stem":434,"answer":69,"indexable":34},"fire-113-1-water-chemical-040","有關射水設備測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"ys":17,"list":436},[437,440,443,446,449,452,455,458,461,464,467,470,473,476,479,482,485,488,491,494,497,500,503,506,509,512,515,518,521,524,527,530,533,536,539,542,545,548,551,554],{"webId":438,"number":31,"stem":439,"answer":43,"indexable":34},"fire-112-1-water-chemical-001","某一新建建築物設有室內消防栓設備，其加壓送水裝置全閉揚程為 60 公尺，今於上午 9 時施作消防立管管系加壓試驗，試驗壓力應…",{"webId":441,"number":37,"stem":442,"answer":43,"indexable":34},"fire-112-1-water-chemical-002","依公共危險物品等場所設置之滅火設備分類，自動撒水設備係屬下列何種滅火設備？",{"webId":444,"number":41,"stem":445,"answer":33,"indexable":34},"fire-112-1-water-chemical-003","室外儲槽儲存閃火點在 70℃以下第四類公共危險物品之顯著滅火困難場所，依規定設置冷卻撒水設備，其加壓送水裝置應設置手動啟動裝…",{"webId":447,"number":46,"stem":448,"answer":33,"indexable":203},"fire-112-1-water-chemical-004","依水道連結型自動撒水設備設置基準之規定，採民生水箱共用式，其配管、配件及閥類之規定，下列敘述何者錯誤？",{"webId":450,"number":51,"stem":451,"answer":43,"indexable":34},"fire-112-1-water-chemical-005","有關補助撒水栓與第二種室內消防栓之比較，下列敘述何者正確？",{"webId":453,"number":55,"stem":454,"answer":43,"indexable":34},"fire-112-1-water-chemical-006","某百貨公司進行消防安全設備檢修作業，天花板上設有密閉式撒水頭，今有一撒水頭側邊有類似樑造型之裝修構造，經測量該密閉式撒水頭與…",{"webId":456,"number":59,"stem":457,"answer":48,"indexable":34},"fire-112-1-water-chemical-007","有關水系統滅火設備之放射（水）區域，下列敘述何者正確？",{"webId":459,"number":63,"stem":460,"answer":69,"indexable":34},"fire-112-1-water-chemical-008","某引擎試驗室設置有泡沫滅火設備，採高發泡放出口局部放射方式，依規定高發泡放出口之泡沫水溶液放射量，防護面積每 1 平方公尺應…",{"webId":462,"number":67,"stem":463,"answer":33,"indexable":34},"fire-112-1-water-chemical-009","室外儲槽儲存閃火點在 70℃以下之第四類公共危險物品之顯著滅火困難場所，應依規定檢討設置下列何種設備？①補助泡沫消防栓 ②泡…",{"webId":465,"number":72,"stem":466,"answer":33,"indexable":34},"fire-112-1-water-chemical-010","水霧滅火設備係利用特殊水霧噴頭，使水呈微粒霧狀及特定角度、形狀噴出，並均勻地覆蓋燃燒表面，達到滅火效果。下列何者非水霧滅火設…",{"webId":468,"number":76,"stem":469,"answer":48,"indexable":34},"fire-112-1-water-chemical-011","建築物高度在 X 公尺以下時，其連結送水管得與室內消防栓共用立管，其管徑在 Y 毫米以上，支管管徑在 Z 毫米以上。其中 X…",{"webId":471,"number":80,"stem":472,"answer":69,"indexable":34},"fire-112-1-water-chemical-012","依據滅火器認可基準規定，由滅火器所充填之滅火藥劑量判別，下列何者屬大型滅火器？",{"webId":474,"number":84,"stem":475,"answer":43,"indexable":34},"fire-112-1-water-chemical-013","依據各類場所消防安全設備設置標準規定，加氣站之滅火器設置，下列敘述何者正確？",{"webId":477,"number":88,"stem":478,"answer":48,"indexable":34},"fire-112-1-water-chemical-014","有關二氧化碳滅火設備相關規定，下列敘述何者正確？",{"webId":480,"number":92,"stem":481,"answer":48,"indexable":34},"fire-112-1-water-chemical-015","有關滅火設備之緊急電源供電容量規定，下列敘述何者錯誤？",{"webId":483,"number":96,"stem":484,"answer":33,"indexable":34},"fire-112-1-water-chemical-016","有關二氧化碳滅火設備構件之安全措施規定，下列敘述何者正確？",{"webId":486,"number":100,"stem":487,"answer":33,"indexable":34},"fire-112-1-water-chemical-017","有關室內消防栓之水平距離、瞄子放水壓力、消防栓及位置之規定，下列敘述何者正確？",{"webId":489,"number":104,"stem":490,"answer":69,"indexable":34},"fire-112-1-water-chemical-018","乾粉滅火設備使用蓄壓用氣體容器，若氣體使用氮氣時，在溫度 35℃，大氣壓力（表壓力） 0 kg\u002Fcm2 狀態下，除加算清洗配…",{"webId":492,"number":108,"stem":493,"answer":69,"indexable":34},"fire-112-1-water-chemical-019","依各類場所消防安全設備設置標準規定，樓地板面積在 X 平方公尺以上之餐廳或供失智照顧型之長期照顧機構使用之場所且樓地板面積合…",{"webId":495,"number":9,"stem":496,"answer":69,"indexable":34},"fire-112-1-water-chemical-020","下列何種海龍替代品滅火劑，其熱分解物不至於產生氟化氫（HF）？",{"webId":498,"number":115,"stem":499,"answer":43,"indexable":34},"fire-112-1-water-chemical-021","某一場所設置有滅火藥劑為 IG-01 之惰性氣體滅火設備，依據消防安全設備測試報告書測試方法及判定要領，針對儲存容器進行外觀…",{"webId":501,"number":119,"stem":502,"answer":48,"indexable":34},"fire-112-1-water-chemical-022","依各類場所消防安全設備設置標準規定，一般場所設置滅火器，下列敘述何者錯誤？",{"webId":504,"number":123,"stem":505,"answer":33,"indexable":34},"fire-112-1-water-chemical-023","依各類場所消防安全設備設置標準規定，下列何種場所不需設置室內消防栓設備？",{"webId":507,"number":127,"stem":508,"answer":43,"indexable":34},"fire-112-1-water-chemical-024","依各類場所消防安全設備設置標準規定，下列何種場所需設置室外消防栓設備？",{"webId":510,"number":131,"stem":511,"answer":48,"indexable":34},"fire-112-1-water-chemical-025","有關公共危險物品場所設置室外消防栓之規定，下列敘述何者錯誤？",{"webId":513,"number":135,"stem":514,"answer":69,"indexable":34},"fire-112-1-water-chemical-026","依據各類場所消防安全設備設置標準，有關撒水頭裝置之規定，下列敘述何者正確？",{"webId":516,"number":139,"stem":517,"answer":69,"indexable":34},"fire-112-1-water-chemical-027","有關自動撒水設備設置流水檢知裝置規定，下列敘述何者正確？",{"webId":519,"number":143,"stem":520,"answer":69,"indexable":34},"fire-112-1-water-chemical-028","有關水霧滅火設備，依各類場所消防安全設備設置標準規定，下列敘述何者正確？",{"webId":522,"number":147,"stem":523,"answer":33,"indexable":34},"fire-112-1-water-chemical-029","有關泡沫滅火設備，依各類場所消防安全設備設置標準規定，下列敘述何者正確？",{"webId":525,"number":151,"stem":526,"answer":69,"indexable":34},"fire-112-1-water-chemical-030","消防幫浦之防止水溫上升用排放裝置，下列敘述何者正確？",{"webId":528,"number":155,"stem":529,"answer":33,"indexable":34},"fire-112-1-water-chemical-031","消防幫浦之性能規定，下列敘述何者錯誤？",{"webId":531,"number":159,"stem":532,"answer":43,"indexable":34},"fire-112-1-water-chemical-032","依各類場所消防安全設備設置標準規定，下列何者應設置消防專用蓄水池？",{"webId":534,"number":163,"stem":535,"answer":69,"indexable":34},"fire-112-1-water-chemical-033","二氧化碳滅火設備滅火藥劑量，下列設置規定何者錯誤？",{"webId":537,"number":167,"stem":538,"answer":48,"indexable":34},"fire-112-1-water-chemical-034","有關自動撒水設備免設撒水頭處所得設置補助撒水栓之規定，下列敘述何者錯誤？",{"webId":540,"number":171,"stem":541,"answer":33,"indexable":34},"fire-112-1-water-chemical-035","二氧化碳滅火設備之滅火藥劑儲存容器，其設置規定下列何者錯誤？",{"webId":543,"number":299,"stem":544,"answer":33,"indexable":34},"fire-112-1-water-chemical-036","乾粉滅火設備採全區或局部之噴頭，下列設置規定何者錯誤？",{"webId":546,"number":175,"stem":547,"answer":69,"indexable":34},"fire-112-1-water-chemical-037","固定式泡沫滅火設備（低發泡）進行綜合檢查作業時，下列敘述何者錯誤？",{"webId":549,"number":179,"stem":550,"answer":33,"indexable":34},"fire-112-1-water-chemical-038","依各類場所消防安全設備設置標準規定，消防專用蓄水池之設置，下列敘述何者錯誤？",{"webId":552,"number":183,"stem":553,"answer":43,"indexable":34},"fire-112-1-water-chemical-039","依各類場所消防安全設備設置標準規定，消防專用蓄水池之採水設置，下列敘述何者錯誤？",{"webId":555,"number":187,"stem":556,"answer":33,"indexable":34},"fire-112-1-water-chemical-040","有關公共危險物品場所設置自動撒水設備規定，下列敘述何者正確？",{"ys":16,"list":558},[559,562,565,567,570,573,576,579,582,585,588,591,594,597,600,603,606,609,612,615,618,621,624,627,630,632,635,638,641,644,647,650,653,656,659,662,665,668,671,674],{"webId":560,"number":31,"stem":561,"answer":33,"indexable":203},"fire-111-1-water-chemical-001","依各類場所消防安全設備設置標準規定，下列何種場所不需設置室外消防栓設備？",{"webId":563,"number":37,"stem":564,"answer":43,"indexable":203},"fire-111-1-water-chemical-002","有關室外消防栓與室內消防栓之瞄子放水壓力之敘述，下列何者正確？",{"webId":566,"number":41,"stem":64,"answer":33,"indexable":203},"fire-111-1-water-chemical-003",{"webId":568,"number":46,"stem":569,"answer":48,"indexable":203},"fire-111-1-water-chemical-004","裝置於舞臺之開放式自動撒水設備，依規定下列何者正確？",{"webId":571,"number":51,"stem":572,"answer":69,"indexable":203},"fire-111-1-water-chemical-005","有關移動式泡沫滅火設備，依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",{"webId":574,"number":55,"stem":575,"answer":43,"indexable":203},"fire-111-1-water-chemical-006","消防幫浦之防止水溫上升用排放裝置，防止水溫上升用之排水管內之流水量，當幫浦在全閉狀態下連續運轉時，不使幫浦內部水溫，升高至攝…",{"webId":577,"number":59,"stem":578,"answer":69,"indexable":203},"fire-111-1-water-chemical-007","下列有關撒水頭設置之敘述，何者正確？",{"webId":580,"number":63,"stem":581,"answer":43,"indexable":203},"fire-111-1-water-chemical-008","固定式泡沫滅火設備（低發泡）進行綜合檢查作業時，發泡倍率應在幾倍以上？",{"webId":583,"number":67,"stem":584,"answer":69,"indexable":203},"fire-111-1-water-chemical-009","泡沫滅火設備之減水警報裝置進行性能檢查時，當呼水槽水量減少到多少時，應發出警報？",{"webId":586,"number":72,"stem":587,"answer":33,"indexable":203},"fire-111-1-water-chemical-010","樓地板面積 250 平方公尺之變壓器室，依各類場所消防安全設備設置標準規定，可選擇下列何種消防安全設備？①水霧 ②泡沫 ③二…",{"webId":589,"number":76,"stem":590,"answer":43,"indexable":203},"fire-111-1-water-chemical-011","依各類場所消防安全設備設置標準規定，消防專用蓄水池應設置於消防車能接近至多少公尺範圍內，易於抽取處？",{"webId":592,"number":80,"stem":593,"answer":33,"indexable":203},"fire-111-1-water-chemical-012","有關水霧滅火設備，依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",{"webId":595,"number":84,"stem":596,"answer":43,"indexable":203},"fire-111-1-water-chemical-013","有關自動撒水設備末端查驗閥之敘述，下列何者正確？",{"webId":598,"number":88,"stem":599,"answer":69,"indexable":203},"fire-111-1-water-chemical-014","開放式自動撒水設備之自動啟動裝置，感知撒水頭應設在裝置面距樓地板面高度多少公尺以下，且能有效探測火災處？",{"webId":601,"number":92,"stem":602,"answer":69,"indexable":203},"fire-111-1-water-chemical-015","採用移動式放射方式之乾粉滅火設備，藥劑種類為第四種乾粉時，每一具噴射瞄子所需藥劑放射量為何？",{"webId":604,"number":96,"stem":605,"answer":33,"indexable":203},"fire-111-1-water-chemical-016","乾粉滅火設備進行性能檢查時，關於滅火藥劑量之敘述，下列何者正確？",{"webId":607,"number":100,"stem":608,"answer":43,"indexable":203},"fire-111-1-water-chemical-017","惰性氣體滅火設備進行綜合檢查時，採低壓式者進行放射試驗時，其放射試驗所需之藥劑量，為該放射區域所設滅火藥劑量之多少以上？",{"webId":610,"number":104,"stem":611,"answer":33,"indexable":203},"fire-111-1-water-chemical-018","依各類場所消防安全設備設置標準規定，總樓地板面積 100 平方公尺之何種場所應設置滅火器？ ①咖啡廳 ②幼兒園 ③陳列館 ④…",{"webId":613,"number":108,"stem":614,"answer":43,"indexable":203},"fire-111-1-water-chemical-019","下列有關滅火器性能檢查之敘述，何者正確？",{"webId":616,"number":9,"stem":617,"answer":69,"indexable":203},"fire-111-1-water-chemical-020","電子工業廠房潔淨室設置消防安全設備，下列敘述何者正確？",{"webId":619,"number":115,"stem":620,"answer":69,"indexable":203},"fire-111-1-water-chemical-021","下列有關乾粉滅火設備設置之規定，何者正確？",{"webId":622,"number":119,"stem":623,"answer":33,"indexable":203},"fire-111-1-water-chemical-022","有關水道連結型自動撒水設備進行綜合檢查時，其放水壓力應為多少？",{"webId":625,"number":123,"stem":626,"answer":69,"indexable":203},"fire-111-1-water-chemical-023","簡易自動滅火設備進行性能檢查時，蓄壓式滅火藥劑儲存容器滅火藥劑量應與標示差異不超過多少？",{"webId":628,"number":127,"stem":629,"answer":48,"indexable":203},"fire-111-1-water-chemical-024","十樓以下建築物之樓層供百貨商場使用，如達到設置自動撒水設備條件，使用密閉式一般反應型撒水頭時，其水源容量應符合幾個撒水頭放水…",{"webId":631,"number":131,"stem":109,"answer":33,"indexable":203},"fire-111-1-water-chemical-025",{"webId":633,"number":135,"stem":634,"answer":33,"indexable":203},"fire-111-1-water-chemical-026","壓力開關高程 0 m，屋頂水箱高程 33 m，最高處撒水頭高程 30 m，加壓送水裝置利用啟動用壓力開關連動啟動。當壓力開關…",{"webId":636,"number":139,"stem":637,"answer":48,"indexable":203},"fire-111-1-water-chemical-027","自動撒水採用密閉乾式或預動式自動撒水設備，撒水頭動作後，流水檢知裝置應在幾分鐘內，使撒水頭放水？",{"webId":639,"number":143,"stem":640,"answer":48,"indexable":203},"fire-111-1-water-chemical-028","依各類場所消防安全設備設置標準之規定，下列何者應設自動撒水設備？",{"webId":642,"number":147,"stem":643,"answer":48,"indexable":203},"fire-111-1-water-chemical-029","變電站場所設置水霧滅火設備，放射區域 6 個分區，其消防幫浦出水量需達每分鐘 X 公升以上；且每顆水霧噴頭放水壓力均能達每平…",{"webId":645,"number":151,"stem":646,"answer":33,"indexable":203},"fire-111-1-water-chemical-030","有關消防安全設備檢修完成標示附加位置，下列敘述何者錯誤？",{"webId":648,"number":155,"stem":649,"answer":43,"indexable":203},"fire-111-1-water-chemical-031","應設置消防專用蓄水池之場所規定，下列何者正確？",{"webId":651,"number":159,"stem":652,"answer":33,"indexable":203},"fire-111-1-water-chemical-032","二氧化碳滅火設備屬於公共危險物品等場所的那一類滅火設備？",{"webId":654,"number":163,"stem":655,"answer":48,"indexable":203},"fire-111-1-water-chemical-033","二氧化碳滅火設備配管，下列設置規定何者錯誤？",{"webId":657,"number":167,"stem":658,"answer":69,"indexable":203},"fire-111-1-water-chemical-034","第五種滅火設備除滅火器外之其他設備，有關滅火效能值核算之規定，下列何者錯誤？",{"webId":660,"number":171,"stem":661,"answer":33,"indexable":203},"fire-111-1-water-chemical-035","二氧化碳滅火設備採全區放射，其噴頭設置規定下列何者錯誤？",{"webId":663,"number":299,"stem":664,"answer":69,"indexable":203},"fire-111-1-water-chemical-036","二氧化碳滅火設備，採用低壓式滅火藥劑儲存容器時，壓力在何範圍會發出警報？",{"webId":666,"number":175,"stem":667,"answer":43,"indexable":203},"fire-111-1-water-chemical-037","依規定 112 年度滅火器檢查合格時，應採用那種顏色檢修環？",{"webId":669,"number":179,"stem":670,"answer":33,"indexable":203},"fire-111-1-water-chemical-038","一間變壓機房採全區放射二氧化碳滅火設備，其防護區域體積 1250 立方公尺，無其它開口部，此防護區域需要多少二氧化碳藥劑量？",{"webId":672,"number":183,"stem":673,"answer":69,"indexable":203},"fire-111-1-water-chemical-039","可燃性高壓氣體儲存場所任一點至滅火器之步行距離在 X 公尺以下，並不得妨礙出入作業；每具滅火器對普通火災具有 Y 個以上之滅…",{"webId":675,"number":187,"stem":676,"answer":43,"indexable":203},"fire-111-1-water-chemical-040","二氧化碳滅火設備採全區放射方式，採用高壓系統在進行綜合檢查時，以空氣或氮氣進行放射試驗，所需空氣量或氮氣量，應就放射區域應設…",{"ys":15,"list":678},[679,682,685,688,691,694,697,700,703,706,709,712,715,718,721,724,727,730,733,736,739,742,745,748,751,754,757,760,763,766,769,772,775,778,781,784,787,790,793,796],{"webId":680,"number":31,"stem":681,"answer":33,"indexable":203},"fire-110-1-water-chemical-001","公共危險物品等場所消防設計及消防安全設備，電氣設備使用之處所，每多少平方公尺（含未滿）應設置第五種滅火設備一具以上？",{"webId":683,"number":37,"stem":684,"answer":69,"indexable":203},"fire-110-1-water-chemical-002","連結送水管之中繼幫浦放水測試時，應從送水口以送水設計壓力送水，並以口徑 21 公厘瞄子在最頂層測試，其放水壓力不得小於 X …",{"webId":686,"number":41,"stem":687,"answer":69,"indexable":203},"fire-110-1-water-chemical-003","公共危險物品等場所消防設計及消防安全設備，顯著滅火困難場所之室外儲槽場所，儲存硫磺，應設置何種滅火設備？",{"webId":689,"number":46,"stem":690,"answer":33,"indexable":203},"fire-110-1-water-chemical-004","下列有關室內消防栓設備之規定，何者錯誤？",{"webId":692,"number":51,"stem":693,"answer":33,"indexable":203},"fire-110-1-water-chemical-005","消防幫浦加壓送水裝置之啟動用水壓開關裝置，下列規定何者正確？",{"webId":695,"number":55,"stem":696,"answer":43,"indexable":203},"fire-110-1-water-chemical-006","有關撒水頭位置裝置之規定，下列敘述何者錯誤？",{"webId":698,"number":59,"stem":699,"answer":33,"indexable":203},"fire-110-1-water-chemical-007","依密閉式撒水頭認可基準規定，其中之耐洩漏試驗，係將撒水頭施予多少之靜水壓力，保持 5 分鐘不得有漏水現象？",{"webId":701,"number":63,"stem":702,"answer":43,"indexable":203},"fire-110-1-water-chemical-008","消防搶救上之必要設備中，連結送水管之送水口設置，下列敘述何者正確？",{"webId":704,"number":67,"stem":705,"answer":33,"indexable":203},"fire-110-1-water-chemical-009","依據密閉式撒水頭認可基準之規定，進行玻璃球之強度試驗時，標示溫度在多少以上者將採用油浴方式進行測試？",{"webId":707,"number":72,"stem":708,"answer":48,"indexable":203},"fire-110-1-water-chemical-010","實施泡沫噴頭外觀檢查，應進行之項目內容不包括下列那一項？",{"webId":710,"number":76,"stem":711,"answer":43,"indexable":203},"fire-110-1-water-chemical-011","室內消防栓設備之加壓送水裝置，若採用壓力水箱方式，則其水箱內空氣不得小於水箱容積的幾分之幾？",{"webId":713,"number":80,"stem":714,"answer":43,"indexable":203},"fire-110-1-water-chemical-012","進行乾粉滅火設備性能檢查時，對於滅火藥劑檢查注意事項，溫度及濕度超過多少以上時，應暫停檢查？",{"webId":716,"number":84,"stem":717,"answer":48,"indexable":203},"fire-110-1-water-chemical-013","使用主成分為碳酸氫鈉之移動放射方式乾粉滅火設備，每一具噴射瞄子之每分鐘藥劑放射量應為下列何者？",{"webId":719,"number":88,"stem":720,"answer":69,"indexable":203},"fire-110-1-water-chemical-014","高壓電器設備其電壓在 7000 伏特以下時，水霧噴頭及配管與高壓電器設備應保持多少公分之標準離開距離？",{"webId":722,"number":92,"stem":723,"answer":33,"indexable":203},"fire-110-1-water-chemical-015","公共危險物品儲槽設置補助泡沫消防栓之規定，下列敘述何者錯誤？",{"webId":725,"number":96,"stem":726,"answer":48,"indexable":203},"fire-110-1-water-chemical-016","某觀光飯店餐廳的廚房面積 750 平方公尺，其使用火源處所設置滅火器核算之最低滅火效能值應為多少？",{"webId":728,"number":100,"stem":729,"answer":33,"indexable":203},"fire-110-1-water-chemical-017","密閉乾式或預動式之流水檢知裝置二次側配管，為有效排水，支管每 10 公尺傾斜 A 公分，主管每 10 公尺傾斜 B 公分。下…",{"webId":731,"number":104,"stem":732,"answer":43,"indexable":203},"fire-110-1-water-chemical-018","有關滅火器設置規定，下列何者錯誤？",{"webId":734,"number":108,"stem":735,"answer":69,"indexable":203},"fire-110-1-water-chemical-019","依各類場所消防安全設備設置標準，應設置室內消防栓設備之場所，下列規定何者正確？",{"webId":737,"number":9,"stem":738,"answer":48,"indexable":203},"fire-110-1-water-chemical-020","飛機修理廠、飛機庫樓地板面積在 200 平方公尺以上者，可就水霧、泡沫、乾粉、二氧化碳滅火設備等選擇下列何者設置之？",{"webId":740,"number":115,"stem":741,"answer":48,"indexable":203},"fire-110-1-water-chemical-021","依各類場所消防安全設備設置標準，應就水霧、泡沫、乾粉、二氧化碳滅火設備等選擇設置之場所，下列場所何者得使用預動式自動撒水設備…",{"webId":743,"number":119,"stem":744,"answer":69,"indexable":203},"fire-110-1-water-chemical-022","同一建築基地內有二棟以上建築物時，建築物間外牆與中心線水平距離第一層在 X 公尺以下，第二層在 Y 公尺以下，且合計各棟該第…",{"webId":746,"number":123,"stem":747,"answer":33,"indexable":203},"fire-110-1-water-chemical-023","下列場所何者可選擇第二種室內消防栓選擇設置之？",{"webId":749,"number":127,"stem":750,"answer":48,"indexable":203},"fire-110-1-water-chemical-024","需設置自動撒水設備之場所中，下列何者應設開放式？",{"webId":752,"number":131,"stem":753,"answer":69,"indexable":203},"fire-110-1-water-chemical-025","自動撒水設備之水源容量規定，若使用側壁型或小區劃型撒水頭時，十層以下樓層在 X 個撒水頭、十一層以上樓層在 Y 個撒水頭繼續…",{"webId":755,"number":135,"stem":756,"answer":33,"indexable":203},"fire-110-1-water-chemical-026","固定式泡沫滅火設備之泡沫放出口，若採用高發泡放出口，其泡沫膨脹比應選擇下列何者設置之？",{"webId":758,"number":139,"stem":759,"answer":33,"indexable":203},"fire-110-1-water-chemical-027","二氧化碳滅火設備之全區放射或局部放射方式防護區域，對放射之滅火藥劑之排放規定，下列何者錯誤？",{"webId":761,"number":143,"stem":762,"answer":43,"indexable":203},"fire-110-1-water-chemical-028","消防專用蓄水池規定之有效水量，指蓄水池深度在基地地面下多少公尺範圍內之水量，但採機械方式引水時，不在此限？",{"webId":764,"number":147,"stem":765,"answer":33,"indexable":203},"fire-110-1-water-chemical-029","公共危險物品等場所消防設計及消防安全設備，設置第五種滅火設備者，公共危險物品每達管制量之幾倍（含未滿）應有一滅火效能值？",{"webId":767,"number":151,"stem":768,"answer":48,"indexable":203},"fire-110-1-water-chemical-030","公共危險物品等場所消防設計及消防安全設備，其他滅火困難場所，應設置第幾種滅火設備？",{"webId":770,"number":155,"stem":771,"answer":48,"indexable":203},"fire-110-1-water-chemical-031","公共危險物品等場所消防設計及消防安全設備，室外消防栓設備採用鑄鐵管配管時，使用符合 CNS 832 規定之壓力管路鑄鐵管或具…",{"webId":773,"number":159,"stem":774,"answer":43,"indexable":203},"fire-110-1-water-chemical-032","公共危險物品等場所消防設計及消防安全設備，有關設置冷卻撒水設備規定，下列何者正確？",{"webId":776,"number":163,"stem":777,"answer":33,"indexable":203},"fire-110-1-water-chemical-033","依消防安全設備及必要檢修項目檢修基準，滅火器設置間距規定，下列何者錯誤？",{"webId":779,"number":167,"stem":780,"answer":33,"indexable":203},"fire-110-1-water-chemical-034","依消防安全設備及必要檢修項目檢修基準，乾粉加壓式滅火器性能檢查之檢查抽樣頻率，應幾年實施一次性能檢查？",{"webId":782,"number":171,"stem":783,"answer":69,"indexable":203},"fire-110-1-water-chemical-035","依消防安全設備及必要檢修項目檢修基準，製造日期超過 10 年或無法辨識製造日期之何種滅火器，非經水壓測試合格，不得再行更換及…",{"webId":785,"number":299,"stem":786,"answer":48,"indexable":203},"fire-110-1-water-chemical-036","依消防安全設備及必要檢修項目檢修基準，自動撒水設備之加壓送水裝置，在減壓措施方面，補助撒水栓放水壓力應在 X kgf\u002Fcm2…",{"webId":788,"number":175,"stem":789,"answer":48,"indexable":203},"fire-110-1-water-chemical-037","依消防安全設備及必要檢修項目檢修基準，水道連結型自動撒水設備之末端查驗閥或連結之水龍頭等日常生活用水設施配置的壓力表，其放水…",{"webId":791,"number":179,"stem":792,"answer":33,"indexable":203},"fire-110-1-water-chemical-038","依消防安全設備及必要檢修項目檢修基準，海龍滅火設備全區放射方式檢查方法，若以空氣或氮氣進行放射試驗，所需空氣量或氮氣量，應就…",{"webId":794,"number":183,"stem":795,"answer":33,"indexable":203},"fire-110-1-water-chemical-039","依消防安全設備及必要檢修項目檢修基準，冷卻撒水設備之遠隔啟動裝置，限用於儲存閃火點多少℃以下公共危險物品之室外儲槽？",{"webId":797,"number":187,"stem":798,"answer":48,"indexable":203},"fire-110-1-water-chemical-040","依消防安全設備及必要檢修項目檢修基準，冷卻撒水設備之供第四類公共危險物品之顯著滅火困難場所之加壓送水裝置，啟動後 X 分鐘內…",{"ys":14,"list":800},[801,804,807,810,813,816,819,822,825,828,831,834,837,840,843,846,849,852,855,858,861,864,867,870,873,876,879,882,885,888,891,894,897,900,903,906,909,912,915,918],{"webId":802,"number":31,"stem":803,"answer":48,"indexable":203},"fire-109-1-water-chemical-001","下列場所何者未達依法應設置滅火器之條件？",{"webId":805,"number":37,"stem":806,"answer":48,"indexable":203},"fire-109-1-water-chemical-002","某地下一層、地上七層建築物，地下層為室內停車空間，面積 200 平方公尺，一至七層為集合住宅，各層面積 100 平方公尺，有…",{"webId":808,"number":41,"stem":809,"answer":33,"indexable":203},"fire-109-1-water-chemical-003","某建築物之室內、外消防栓、自動撒水及水霧滅火等設備配管採連通設計並共用消防幫浦，其共用消防幫浦之出水量和全揚程之要求標準為何…",{"webId":811,"number":46,"stem":812,"answer":33,"indexable":203},"fire-109-1-water-chemical-004","供集會堂使用之舞臺，應設置何種自動撒水設備？",{"webId":814,"number":51,"stem":815,"answer":33,"indexable":203},"fire-109-1-water-chemical-005","某電信機械室設置二氧化碳全區放射滅火設備，其核算之滅火藥劑量應於多少時間內全部放射完畢？",{"webId":817,"number":55,"stem":818,"answer":69,"indexable":203},"fire-109-1-water-chemical-006","消防幫浦設置呼水槽時，防止水溫上升用排放裝置之標稱口徑不得小於多少毫米？",{"webId":820,"number":59,"stem":821,"answer":33,"indexable":203},"fire-109-1-water-chemical-007","下列何者非為消防機關辦理建築物消防安全設備審查及查驗作業基準規定，申請消防專用蓄水池查驗應檢附安裝施工測試佐證資料？",{"webId":823,"number":63,"stem":824,"answer":33,"indexable":203},"fire-109-1-water-chemical-008","預動式自動撒水設備竣工測試進行放水試驗時，開放末端查驗閥後，應在多久時間內正常放水？",{"webId":826,"number":67,"stem":827,"answer":33,"indexable":203},"fire-109-1-water-chemical-009","進行低發泡水成膜泡沫放射試驗時，其 25%還原時間應在多久時間以上？",{"webId":829,"number":72,"stem":830,"answer":69,"indexable":203},"fire-109-1-water-chemical-010","全區放射方式之二氧化碳滅火設備，應設置從啟動裝置動作至二氧化碳放出時間至少多久的遲延裝置？",{"webId":832,"number":76,"stem":833,"answer":33,"indexable":203},"fire-109-1-water-chemical-011","乾粉滅火設備之緊急電源應為發電機設備或蓄電池設備，其容量應能使該設備有效動作多少時間以上？",{"webId":835,"number":80,"stem":836,"answer":48,"indexable":203},"fire-109-1-water-chemical-012","消防水系統設置呼水裝置時，其溢水用排水管口徑應在多少尺寸以上？",{"webId":838,"number":84,"stem":839,"answer":69,"indexable":203},"fire-109-1-water-chemical-013","乾粉滅火設備設置啟動用氣體容器時，其容器之內容積應有多少以上？",{"webId":841,"number":88,"stem":842,"answer":43,"indexable":203},"fire-109-1-water-chemical-014","測量室內消防栓瞄子直線放水之壓力時，應將壓力表之進水口，放置於瞄子前端多少距離處，讀取壓力表的指示值？",{"webId":844,"number":92,"stem":845,"answer":48,"indexable":203},"fire-109-1-water-chemical-015","公共危險物品室外儲槽場所設置射水設備時，測試之放水壓力應在多少以上？",{"webId":847,"number":96,"stem":848,"answer":43,"indexable":203},"fire-109-1-water-chemical-016","製造年份超過 10 年之室內消防栓水帶進行耐水壓試驗時，施以 7 kgf\u002Fcm²以上水壓試驗多久時間，始得視為合格可繼續使用…",{"webId":850,"number":100,"stem":851,"answer":43,"indexable":203},"fire-109-1-water-chemical-017","某爆竹煙火儲存場所設置室外消防栓設備共 8 具，進行設備檢修綜合檢查時，至少應選擇配管上最遠最高處多少數量之室外消防栓實施放…",{"webId":853,"number":104,"stem":854,"answer":33,"indexable":203},"fire-109-1-water-chemical-018","移動式泡沫滅火設備進行綜合檢查作業時，發泡倍率應在幾倍以上？",{"webId":856,"number":108,"stem":857,"answer":33,"indexable":203},"fire-109-1-water-chemical-019","某室內停車空間設置低發泡固定式泡沫滅火設備，每次檢修作業時，應選擇全部放射區域數多少比例以上之放射區域進行逐區放水試驗，測其…",{"webId":859,"number":9,"stem":860,"answer":48,"indexable":203},"fire-109-1-water-chemical-020","用於防護電氣設施之水霧滅火設備進行放水試驗時，最末端放射區域全部水霧噴頭之放水壓力均應能達到多少壓力以上？",{"webId":862,"number":115,"stem":863,"answer":69,"indexable":203},"fire-109-1-water-chemical-021","室內消防栓中之減水警報裝置，應於水量減至多少時發出警報？",{"webId":865,"number":119,"stem":866,"answer":43,"indexable":203},"fire-109-1-water-chemical-022","室內消防栓之箱面字樣，每字不得小於多少平方公分？",{"webId":868,"number":123,"stem":869,"answer":48,"indexable":203},"fire-109-1-water-chemical-023","下列有關室內消防栓箱之敘述，何者正確？",{"webId":871,"number":127,"stem":872,"answer":43,"indexable":203},"fire-109-1-water-chemical-024","室外消防栓設備之水帶箱設置，箱內應配置口徑 63 毫米及長多少公尺之水帶 2 條？",{"webId":874,"number":131,"stem":875,"answer":33,"indexable":203},"fire-109-1-water-chemical-025","高架倉庫內所設置之撒水頭，其放水量每分鐘應在多少公升以上？",{"webId":877,"number":135,"stem":878,"answer":69,"indexable":203},"fire-109-1-water-chemical-026","密閉式撒水頭之自動撒水設備末端查驗閥規定，下列何者錯誤？",{"webId":880,"number":139,"stem":881,"answer":69,"indexable":203},"fire-109-1-water-chemical-027","中央消防主管機關認定儲存大量可燃物之場所天花板高度超過 6 公尺，或其他場所天花板高度超過 10 公尺者，應採用何種撒水頭？",{"webId":883,"number":143,"stem":884,"answer":48,"indexable":203},"fire-109-1-water-chemical-028","水霧滅火設備之放射區域有 2 區以上者，其主管管徑不得小於多少毫米？",{"webId":886,"number":147,"stem":887,"answer":48,"indexable":203},"fire-109-1-water-chemical-029","泡沫原液與水混合使用之濃度，下列何種原液之濃度為 1%？",{"webId":889,"number":151,"stem":890,"answer":43,"indexable":203},"fire-109-1-water-chemical-030","泡沫滅火設備計算之水溶液量，應加算充滿配管所需之泡沫水溶液量，且應加算總泡沫水溶液量之百分之多少？",{"webId":892,"number":155,"stem":893,"answer":33,"indexable":203},"fire-109-1-water-chemical-031","使用水成膜泡沫液時，樓地板面積每平方公尺之泡沫頭放射量為每分鐘多少公升以上？",{"webId":895,"number":159,"stem":896,"answer":43,"indexable":203},"fire-109-1-water-chemical-032","二氧化碳滅火設備採用移動放射方式時，每一具噴射瞄子所需滅火藥劑量在多少公斤以上？",{"webId":898,"number":163,"stem":899,"answer":33,"indexable":203},"fire-109-1-water-chemical-033","加壓式乾粉滅火設備應設壓力調整裝置，其可調整壓力至每平方公分多少公斤以下？",{"webId":901,"number":167,"stem":902,"answer":69,"indexable":203},"fire-109-1-water-chemical-034","乾粉滅火設備使用加壓或蓄壓用氣體容器，其所使用之氣體為下列何者？",{"webId":904,"number":171,"stem":905,"answer":43,"indexable":203},"fire-109-1-water-chemical-035","廚房等大量使用火源之處所，多少樓地板面積需有一滅火效能值？",{"webId":907,"number":299,"stem":908,"answer":33,"indexable":203},"fire-109-1-water-chemical-036","任一消防專用蓄水池至建築物各部分之水平距離不得超過多少公尺？",{"webId":910,"number":175,"stem":911,"answer":69,"indexable":203},"fire-109-1-water-chemical-037","連結送水管之配管設置規定，應能承受送水設計壓力 1.5 倍以上之水壓，且能持續多少時間才合格？",{"webId":913,"number":179,"stem":914,"answer":43,"indexable":203},"fire-109-1-water-chemical-038","消防專用蓄水池之設置規定，下列何者正確？",{"webId":916,"number":183,"stem":917,"answer":48,"indexable":203},"fire-109-1-water-chemical-039","公共危險品等場所中，所設置之室外消防栓設備，其緊急電源之供電容量應供其有效動作多久以上？",{"webId":919,"number":187,"stem":920,"answer":43,"indexable":203},"fire-109-1-water-chemical-040","儲槽規定設置補助泡沫消防栓時，下列敘述何者錯誤？",{"ys":13,"list":922},[923,926,929,932,935,938,941,944,947,950,953,956,959,962,965,968,971,974,977,980,983,986,989,992,995,998,1001,1004,1007,1010,1013,1016,1019,1022,1025,1028,1031,1034,1037,1040],{"webId":924,"number":31,"stem":925,"answer":48,"indexable":203},"fire-108-1-water-chemical-001","在應設置室內消防栓設備之場所，但設有室外消防栓設備時，在第一層水平距離 X 公尺以下、第二層步行距離 Y 公尺以下有效滅火範…",{"webId":927,"number":37,"stem":928,"answer":48,"indexable":203},"fire-108-1-water-chemical-002","自動撒水設備竣工時，應做加壓試驗。但密閉乾式管系應併行空氣壓試驗，試驗時，應使空氣壓力達到 X MPa 之標準，其壓力持續 …",{"webId":930,"number":41,"stem":931,"answer":33,"indexable":203},"fire-108-1-water-chemical-003","中央主管機關認定儲存大量可燃物之場所天花板高度超過 X 公尺，或其他場所天花板高度超過 Y 公尺者，應採用放水型撒水頭。X、…",{"webId":933,"number":46,"stem":934,"answer":48,"indexable":203},"fire-108-1-water-chemical-004","密閉乾式或預動式自動撒水設備，下列設置規定何者正確？",{"webId":936,"number":51,"stem":937,"answer":69,"indexable":203},"fire-108-1-water-chemical-005","開放式自動撒水設備之自動及手動啟動裝置，下列設置規定何者正確？",{"webId":939,"number":55,"stem":940,"answer":43,"indexable":203},"fire-108-1-water-chemical-006","使用密閉式撒水頭之自動撒水設備末端之查驗閥，下列設置規定何者正確？",{"webId":942,"number":59,"stem":943,"answer":48,"indexable":203},"fire-108-1-water-chemical-007","有關水霧滅火設備，下列設置規定何者錯誤？",{"webId":945,"number":63,"stem":946,"answer":33,"indexable":203},"fire-108-1-water-chemical-008","移動式泡沫滅火設備之加壓送水裝置使用消防幫浦時，若同一樓層設 3 個泡沫消防栓箱時，其出水量應在每分鐘多少公升以上？",{"webId":948,"number":67,"stem":949,"answer":43,"indexable":203},"fire-108-1-water-chemical-009","有一總機室，設置二氧化碳滅火設備，採全區放射方式，其每立方公尺防護區域所需滅火藥劑量為多少公斤？",{"webId":951,"number":72,"stem":952,"answer":48,"indexable":203},"fire-108-1-water-chemical-010","有一電信機械室，設置二氧化碳滅火設備，採全區放射方式，其所核算之滅火藥劑量應於多少秒內全部放射完畢？",{"webId":954,"number":76,"stem":955,"answer":33,"indexable":203},"fire-108-1-water-chemical-011","二氧化碳滅火設備使用氣體啟動者，啟動用氣體容器之內容積應有 1 公升以上，其所儲存之二氧化碳重量在 0.6 公斤以上，且其充…",{"webId":957,"number":80,"stem":958,"answer":69,"indexable":203},"fire-108-1-water-chemical-012","主成分為碳酸氫鉀及尿素化合物之乾粉滅火藥劑，採全區放射方式時，每立方公尺防護區域所需滅火藥劑量為多少公斤？",{"webId":960,"number":84,"stem":961,"answer":43,"indexable":203},"fire-108-1-water-chemical-013","依各類場所消防安全設備設置標準之規定，乾粉滅火設備配管及閥類，下列設置規定何者錯誤？",{"webId":963,"number":88,"stem":964,"answer":33,"indexable":203},"fire-108-1-water-chemical-014","依各類場所消防安全設備設置標準之規定，加壓式乾粉滅火設備應設壓力調整裝置，可調整壓力至若干 MPa 以下？",{"webId":966,"number":92,"stem":967,"answer":33,"indexable":203},"fire-108-1-water-chemical-015","依各類場所消防安全設備檢修及申報作業基準，對蓄壓式二氧化碳滅火器及海龍滅火器進行重量檢查時，如失重超過多少%以上或壓力表示值…",{"webId":969,"number":96,"stem":970,"answer":48,"indexable":203},"fire-108-1-water-chemical-016","依各類場所消防安全設備檢修及申報作業基準，公共危險物品等場所達顯著滅火困難者設置之第一種滅火設備之室內消防栓，其放水壓力應在…",{"webId":972,"number":100,"stem":973,"answer":33,"indexable":203},"fire-108-1-water-chemical-017","依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備之第一種消防栓水帶及瞄子檢查方法，製造年份超過 10 年或無法辨…",{"webId":975,"number":104,"stem":976,"answer":48,"indexable":203},"fire-108-1-water-chemical-018","依各類場所消防安全設備檢修及申報作業基準，固定式泡沫滅火設備（低發泡）綜合檢查，設置泡沫頭者，每次選擇全部放射區域數之若干%…",{"webId":978,"number":108,"stem":979,"answer":33,"indexable":203},"fire-108-1-water-chemical-019","依各類場所消防安全設備檢修及申報作業基準，有關高壓式二氧化碳滅火藥劑儲存容器之滅火藥劑量檢查方法之注意事項中，鈷 60 有效…",{"webId":981,"number":9,"stem":982,"answer":69,"indexable":203},"fire-108-1-water-chemical-020","公共危險物品等場所之滅火設備分類，下列敘述何者錯誤？",{"webId":984,"number":115,"stem":985,"answer":43,"indexable":203},"fire-108-1-water-chemical-021","某鍋爐房樓地板面積為 20 m×15 m，依法其所需之滅火效能值為何？",{"webId":987,"number":119,"stem":988,"answer":69,"indexable":203},"fire-108-1-water-chemical-022","有關潔淨藥劑氣體滅火設備滅火藥劑主要成分之敘述，下列何者正確？",{"webId":990,"number":123,"stem":991,"answer":43,"indexable":203},"fire-108-1-water-chemical-023","依各類場所消防安全設備設置標準之規定，有關應設置室外消防栓設備之場所，下列敘述何者正確？",{"webId":993,"number":127,"stem":994,"answer":33,"indexable":203},"fire-108-1-water-chemical-024","某一 15 樓層之建築物，其消防安全設備同時設有第一種室內消防栓及自動撒水設備，其屋頂水箱容量至少應為下列何者？",{"webId":996,"number":131,"stem":997,"answer":48,"indexable":203},"fire-108-1-water-chemical-025","下列何者不屬於各類場所消防安全設備設置標準第 8 條所規定的滅火設備？",{"webId":999,"number":135,"stem":1000,"answer":43,"indexable":203},"fire-108-1-water-chemical-026","依各類場所消防安全設備設置標準之規定，建築物高度超過 60 公尺者，連結送水管應採用濕式，其中繼幫浦設置規定之敘述何者錯誤？",{"webId":1002,"number":139,"stem":1003,"answer":33,"indexable":203},"fire-108-1-water-chemical-027","依各類場所消防安全設備設置標準之規定，室外消防栓於其 I 公尺範圍內附設水帶箱，在 J 公尺以內，保持空曠，不得堆放物品或種…",{"webId":1005,"number":143,"stem":1006,"answer":69,"indexable":203},"fire-108-1-water-chemical-028","依法令規定在應設水霧、泡沫、乾粉、二氧化碳滅火設備之場所，但外牆開口面積（常時開放部分）達該層樓地板面積百分之多少以上者，上…",{"webId":1008,"number":147,"stem":1009,"answer":43,"indexable":203},"fire-108-1-water-chemical-029","有一室內停車空間，其防護區為 25 m × 16 m × 4 m，未設自動關閉裝置之開口部面積為 10 m2，擬設置全區放射…",{"webId":1011,"number":151,"stem":1012,"answer":69,"indexable":203},"fire-108-1-water-chemical-030","依滅火器設置規定，下列何者錯誤？",{"webId":1014,"number":155,"stem":1015,"answer":48,"indexable":203},"fire-108-1-water-chemical-031","第四種乾粉滅火藥劑儲存容器，有關充填比之規定，下列何者正確？",{"webId":1017,"number":159,"stem":1018,"answer":69,"indexable":203},"fire-108-1-water-chemical-032","依法令規定下列場所何者應設置滅火器？",{"webId":1020,"number":163,"stem":1021,"answer":43,"indexable":203},"fire-108-1-water-chemical-033","某百貨商場（10 樓以下）內設有一般反應型撒水頭 15 個，試問其消防幫浦最低出水量應為何？",{"webId":1023,"number":167,"stem":1024,"answer":48,"indexable":203},"fire-108-1-water-chemical-034","依各類場所消防安全設備設置標準之規定，水霧滅火設備之加壓送水裝置使用消防幫浦時，用於防護電氣設備者，每一個水霧噴頭壓力依規定…",{"webId":1026,"number":171,"stem":1027,"answer":33,"indexable":203},"fire-108-1-water-chemical-035","依各類場所消防安全設備檢修及申報作業基準，有關室內消防栓設備呼水裝置之減水警報裝置，當水量減少至多少前應發出警報？",{"webId":1029,"number":299,"stem":1030,"answer":33,"indexable":203},"fire-108-1-water-chemical-036","依各類場所消防安全設備設置標準之規定，高發泡放出口在全區放射防護區域內，樓地板面積每多少平方公尺應至少設置 1 個，且能有效…",{"webId":1032,"number":175,"stem":1033,"answer":43,"indexable":203},"fire-108-1-water-chemical-037","進行滅火器之檢查時，有關一般注意事項，下列何者錯誤？",{"webId":1035,"number":179,"stem":1036,"answer":69,"indexable":203},"fire-108-1-water-chemical-038","依各類場所消防安全設備檢修及申報作業基準，有關乾粉滅火藥劑判定方法，乾粉藥劑不得有雜質、變質、固化等情形，且以手輕握搓揉，並…",{"webId":1038,"number":183,"stem":1039,"answer":69,"indexable":203},"fire-108-1-water-chemical-039","依各類場所消防安全設備設置標準之規定，公共危險物品室外儲槽場所之冷卻撒水設備如以幫浦方式進行加壓時，實際測得之放射量除以該冷…",{"webId":1041,"number":187,"stem":1042,"answer":48,"indexable":203},"fire-108-1-water-chemical-040","電動機之使用應符合之相關規定，下列何者錯誤？",{"ys":12,"list":1044},[1045,1048,1051,1054,1057,1060,1063,1066,1069,1072,1075,1078,1081,1084,1087,1090,1093,1096,1099,1102,1105,1108,1111,1114,1117,1120,1123,1126,1129,1132,1135,1138,1141,1144,1147,1150,1152,1155,1158,1161],{"webId":1046,"number":31,"stem":1047,"answer":48,"indexable":203},"fire-107-1-water-chemical-001","撒水頭之設置位置規定中，撒水頭迴水板下方 A 公分內及水平方向 B 公分內，應保持淨空間，不得有障礙物，其中 A、B 分別為…",{"webId":1049,"number":37,"stem":1050,"answer":69,"indexable":203},"fire-107-1-water-chemical-002","有關連結送水管之送水口設置規定，下列何者錯誤？",{"webId":1052,"number":41,"stem":1053,"answer":48,"indexable":203},"fire-107-1-water-chemical-003","水霧滅火設備之水源容量規定，下列何者正確？",{"webId":1055,"number":46,"stem":1056,"answer":43,"indexable":203},"fire-107-1-water-chemical-004","移動式泡沫滅火設備之水源容量，依規定為 2 具泡沫瞄子同時放水多少分鐘之水量以上？",{"webId":1058,"number":51,"stem":1059,"answer":69,"indexable":203},"fire-107-1-water-chemical-005","泡沫滅火設備使用泡沫噴頭時，每一放射區域之樓地板面積規定應為何？",{"webId":1061,"number":55,"stem":1062,"answer":43,"indexable":203},"fire-107-1-water-chemical-006","泡沫滅火系統中，採高發泡全區放射時，冠泡體積係指防護區域自樓地板面至高出防護對象最高點多少公尺所圍體積？",{"webId":1064,"number":59,"stem":1065,"answer":33,"indexable":203},"fire-107-1-water-chemical-007","自動撒水設備應裝置適當之流水檢知裝置，有關流水檢知裝置之設置規定，下列何者正確？",{"webId":1067,"number":63,"stem":1068,"answer":33,"indexable":203},"fire-107-1-water-chemical-008","水滅火系統中，以立管連接屋頂水箱使配管平時充滿水，屋頂水箱之容量要求，下列何者錯誤？",{"webId":1070,"number":67,"stem":1071,"answer":43,"indexable":203},"fire-107-1-water-chemical-009","某一學校教學大樓每一樓層皆設有第一種室內消防栓 3 具，則其水源容量應為多少立方公尺？",{"webId":1073,"number":72,"stem":1074,"answer":33,"indexable":203},"fire-107-1-water-chemical-010","第一種室內消防栓採用消防幫浦做為加壓送水裝置時，假設水帶摩擦損失水頭為 3 m，配管磨擦損失水頭為 7 m，落差為 30 m…",{"webId":1076,"number":76,"stem":1077,"answer":48,"indexable":203},"fire-107-1-water-chemical-011","加壓式乾粉滅火設備，於啟動裝置動作後，為使儲存容器壓力達設定壓力始開啟放出閥，應設置何種裝置？",{"webId":1079,"number":80,"stem":1080,"answer":48,"indexable":203},"fire-107-1-water-chemical-012","設置乾粉滅火設備時，全區及局部放射之緊急電源應為自用發電設備或蓄電池設備，其容量應能使設備有效動作多久以上？",{"webId":1082,"number":84,"stem":1083,"answer":48,"indexable":203},"fire-107-1-water-chemical-013","有關二氧化碳滅火設備配管之設置規定，下列何者正確？",{"webId":1085,"number":88,"stem":1086,"answer":43,"indexable":203},"fire-107-1-water-chemical-014","二氧化碳滅火系統採全區放射方式高壓式系統，共設有 24 瓶儲存容器，進行綜合檢查時，放射試驗所需之藥劑量，應為下列何者？",{"webId":1088,"number":92,"stem":1089,"answer":43,"indexable":203},"fire-107-1-water-chemical-015","二氧化碳滅火系統進行性能檢查時，音響警報之判定方法為距警報裝置 X 公尺處之音量應在 Y 分貝以上，其中 X、Y 應為下列何…",{"webId":1091,"number":96,"stem":1092,"answer":33,"indexable":203},"fire-107-1-water-chemical-016","有關乾粉滅火系統之放射時間，下列敘述何者正確？",{"webId":1094,"number":100,"stem":1095,"answer":69,"indexable":203},"fire-107-1-water-chemical-017","一電氣設備室長寬高分別為 12 m、8 m 及 4 m，若採二氧化碳全區放射滅火設備防護，藥劑放射後採機械排放，則其排風機之…",{"webId":1097,"number":104,"stem":1098,"answer":33,"indexable":203},"fire-107-1-water-chemical-018","有關大型滅火器之敘述，下列何者正確？",{"webId":1100,"number":108,"stem":1101,"answer":43,"indexable":203},"fire-107-1-water-chemical-019","可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽之滅火器，每具滅火器對普通火災應具有 X 個以上之滅火效能值，對油…",{"webId":1103,"number":9,"stem":1104,"answer":43,"indexable":203},"fire-107-1-water-chemical-020","室內消防栓之水源採重力水箱設置，下列何種裝置不屬於該構造應有之裝置？",{"webId":1106,"number":115,"stem":1107,"answer":69,"indexable":203},"fire-107-1-water-chemical-021","有關乾粉滅火設備配管設置規定，下列敘述何者正確？",{"webId":1109,"number":119,"stem":1110,"answer":48,"indexable":203},"fire-107-1-water-chemical-022","可燃性高壓氣體場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽設置滅火器，其設置規定，下列敘述何者正確？",{"webId":1112,"number":123,"stem":1113,"answer":43,"indexable":203},"fire-107-1-water-chemical-023","有關室內消防栓綜合檢查放水量及放水壓力之敘述，下列何者正確？",{"webId":1115,"number":127,"stem":1116,"answer":33,"indexable":203},"fire-107-1-water-chemical-024","竣工查驗時，於屋頂使用口徑 16 mm 瞄子實施第一種室內消防栓綜合檢查，測得放水壓力為 4 kgf\u002Fcm2，所計算之每分鐘…",{"webId":1118,"number":131,"stem":1119,"answer":69,"indexable":203},"fire-107-1-water-chemical-025","泡沫滅火設備進行綜合檢查時，有關泡沫滅火藥劑 25%還原時間標準值敘述，下列何者正確？",{"webId":1121,"number":135,"stem":1122,"answer":48,"indexable":203},"fire-107-1-water-chemical-026","室內消防栓設備之消防立管管系竣工時，應做加壓試驗，試驗壓力不得小於加壓送水裝置全閉揚程 A 倍以上之水壓。試驗壓力以繼續維持…",{"webId":1124,"number":139,"stem":1125,"answer":33,"indexable":203},"fire-107-1-water-chemical-027","有關二氧化碳滅火設備放射時間之敘述，下列何者正確？",{"webId":1127,"number":143,"stem":1128,"answer":69,"indexable":203},"fire-107-1-water-chemical-028","有關滅火器性能檢查頻率之規定，下列敘述何者正確？",{"webId":1130,"number":147,"stem":1131,"answer":43,"indexable":203},"fire-107-1-water-chemical-029","全區放射二氧化碳滅火設備進行綜合檢查時，如為高壓式儲存系統，在放射試驗時需放射多少藥劑量？",{"webId":1133,"number":151,"stem":1134,"answer":48,"indexable":203},"fire-107-1-water-chemical-030","實施二氧化碳滅火設備檢修，於進行性能檢查時，皮管連接部應無鬆動，皮管損傷、老化等情形，且皮管長度應在幾公尺以上？",{"webId":1136,"number":155,"stem":1137,"answer":43,"indexable":203},"fire-107-1-water-chemical-031","惰性氣體滅火設備進行性能檢查時，對於滅火藥劑量判定方法，藥劑量測定結果與重量表、圖面明細表或原廠技術手冊規範等資料核對，其差…",{"webId":1139,"number":159,"stem":1140,"answer":33,"indexable":203},"fire-107-1-water-chemical-032","泡沫滅火設備之場所，於進行性能檢查時，製造年份超過幾年或無法辨識製造年份之水帶，應進行水壓試驗？",{"webId":1142,"number":163,"stem":1143,"answer":33,"indexable":203},"fire-107-1-water-chemical-033","自動撒水設備竣工時進行加壓試驗，下列何者錯誤？",{"webId":1145,"number":167,"stem":1146,"answer":43,"indexable":203},"fire-107-1-water-chemical-034","依 NFPA 2001 之規定，潔淨式氣體滅火系統於一般場所之藥劑放射時間（達設計濃度 95%之時間），下列敘述何者正確？",{"webId":1148,"number":171,"stem":1149,"answer":33,"indexable":203},"fire-107-1-water-chemical-035","採用移動式放射方式之乾粉滅火設備，藥劑種類為第一種乾粉時，每一具噴射瞄子所需藥劑放射量為：",{"webId":1151,"number":299,"stem":596,"answer":43,"indexable":203},"fire-107-1-water-chemical-036",{"webId":1153,"number":175,"stem":1154,"answer":48,"indexable":203},"fire-107-1-water-chemical-037","有關撒水頭設置之敘述，下列何者正確？",{"webId":1156,"number":179,"stem":1157,"answer":33,"indexable":203},"fire-107-1-water-chemical-038","依各類場所消防安全設備設置標準之規定，下列何種場所不需設置室外消防栓設備？",{"webId":1159,"number":183,"stem":1160,"answer":69,"indexable":203},"fire-107-1-water-chemical-039","為執行檢修申報，針對水霧滅火系統綜合檢查，對於判定方法之敘述，下列何者正確？",{"webId":1162,"number":187,"stem":1163,"answer":69,"indexable":203},"fire-107-1-water-chemical-040","進行幫浦性能試驗時，幫浦之出水量在額定出水量之 1.5 倍時，其全揚程應為額定出水量在性能曲線上全揚程百分之多少以上？",{"ys":11,"list":1165},[1166,1169,1172,1175,1178,1181,1184,1187,1190,1193,1196,1199,1202,1205,1208,1211,1214,1217,1220,1223,1226,1229,1232,1235,1238,1241,1244,1247,1250,1253,1256,1259,1262,1265,1268,1271,1274,1277,1280,1283],{"webId":1167,"number":31,"stem":1168,"answer":48,"indexable":203},"fire-106-1-water-chemical-001","依 NFPA 2001 之規定，潔淨式氣體滅火系統於一般場所之藥劑放射時間（達設計濃度 95%之時間），下列何者錯誤？",{"webId":1170,"number":37,"stem":1171,"answer":33,"indexable":203},"fire-106-1-water-chemical-002","依各類場所消防安全設備設置標準，下列何種場所不需設置滅火器？",{"webId":1173,"number":41,"stem":1174,"answer":43,"indexable":203},"fire-106-1-water-chemical-003","有關滅火器設置間距之規定，下列何者錯誤？",{"webId":1176,"number":46,"stem":1177,"answer":69,"indexable":203},"fire-106-1-water-chemical-004","依滅火器認可基準，大型滅火器充填乾粉時，滅火藥劑量需在多少公斤以上？",{"webId":1179,"number":51,"stem":1180,"answer":33,"indexable":203},"fire-106-1-water-chemical-005","某一鍋爐房之長寬高分別為 8 m、5 m 及 4 m，若設置全區放射 CO2 滅火設備，其所有開口皆可在放射前自動關閉，試問…",{"webId":1182,"number":55,"stem":1183,"answer":48,"indexable":203},"fire-106-1-water-chemical-006","全區放射二氧化碳滅火設備進行綜合檢查時，如為低壓式儲存系統，在放射試驗時需放射多少藥劑量？",{"webId":1185,"number":59,"stem":1186,"answer":48,"indexable":203},"fire-106-1-water-chemical-007","依各類場所消防安全設備設置標準，二氧化碳滅火設備之藥劑放射時間，下列何者正確？",{"webId":1188,"number":63,"stem":1189,"answer":69,"indexable":203},"fire-106-1-water-chemical-008","乾粉滅火設備進行性能檢查時，滅火藥劑檢查注意事項中，溫度超過Ｘ℃以上，濕度超過Ｙ%以上時，應暫停檢查，Ｘ及Ｙ分別為：",{"webId":1191,"number":67,"stem":1192,"answer":48,"indexable":203},"fire-106-1-water-chemical-009","如無額外防止乾粉與加壓氣體分離之措施，乾粉滅火設備之配管任一部分與彎曲部分之距離，至少應為其管徑的多少倍？",{"webId":1194,"number":72,"stem":1195,"answer":69,"indexable":203},"fire-106-1-water-chemical-010","一汽車修理廠欲採用移動式乾粉滅火設備，則其外牆開口面積（常時開放部分）須符合下列那一規定？",{"webId":1197,"number":76,"stem":1198,"answer":48,"indexable":203},"fire-106-1-water-chemical-011","鹵化烴滅火設備進行性能檢查時，控制裝置之遲延裝置檢查項目，於操作啟動按鈕後至容器閥開放裝置動作，其所需時間應為：",{"webId":1200,"number":80,"stem":1201,"answer":69,"indexable":203},"fire-106-1-water-chemical-012","簡易自動滅火設備進行性能檢查時，其蓄壓式滅火藥劑量應與標示重量差異在何範圍以內？",{"webId":1203,"number":84,"stem":1204,"answer":33,"indexable":203},"fire-106-1-water-chemical-013","有關室內消防栓之放水壓力，下列何者錯誤？",{"webId":1206,"number":88,"stem":1207,"answer":43,"indexable":203},"fire-106-1-water-chemical-014","達顯著滅火困難之公共危險物品室外儲存場所，設置室外消防栓設備，其緊急電源應使用發電機設備或蓄電池設備，供電容量應供其有效動作…",{"webId":1209,"number":92,"stem":1210,"answer":43,"indexable":203},"fire-106-1-water-chemical-015","某一高度危險工作場所，其建築物外面設有 4 具室外消防栓，則其水源容量至少應為多少？",{"webId":1212,"number":96,"stem":1213,"answer":33,"indexable":203},"fire-106-1-water-chemical-016","自動撒水設備竣工時進行加壓試驗，下列何者正確？",{"webId":1215,"number":100,"stem":1216,"answer":48,"indexable":203},"fire-106-1-water-chemical-017","有關撒水頭之設置，下列敘述何者錯誤？",{"webId":1218,"number":104,"stem":1219,"answer":69,"indexable":203},"fire-106-1-water-chemical-018","公共危險物品等場所設置自動撒水設備時，使用密閉式撒水頭其水源容量，應在設置 X 個撒水頭繼續放水 Y 分鐘之水量以上，其中 …",{"webId":1221,"number":108,"stem":1222,"answer":48,"indexable":203},"fire-106-1-water-chemical-019","進行密閉濕式撒水設備綜合檢查時，末端查驗管之放水壓力應在那個範圍？",{"webId":1224,"number":9,"stem":1225,"answer":43,"indexable":203},"fire-106-1-water-chemical-020","水霧滅火設備之加壓送水裝置使用消防幫浦時，其出水量及出水壓力，下列敘述何者錯誤？",{"webId":1227,"number":115,"stem":1228,"answer":69,"indexable":203},"fire-106-1-water-chemical-021","裝置水霧滅火設備之室內停車空間，其排水設備應符合之規定，下列何者錯誤？",{"webId":1230,"number":119,"stem":1231,"answer":43,"indexable":203},"fire-106-1-water-chemical-022","下列那一泡沫滅火設備之泡沫濃度，不符泡沫原液與水混合使用濃度之規定？",{"webId":1233,"number":123,"stem":1234,"answer":43,"indexable":203},"fire-106-1-water-chemical-023","泡沫滅火設備進行綜合檢查時，有關蛋白質泡沫滅火藥劑之發泡倍率至少應為何？",{"webId":1236,"number":127,"stem":1237,"answer":43,"indexable":203},"fire-106-1-water-chemical-024","公共危險物品等場所設置移動式泡沫滅火設備時，其水源容量與放水量之規定，下列何者錯誤？",{"webId":1239,"number":131,"stem":1240,"answer":48,"indexable":203},"fire-106-1-water-chemical-025","某一防護對象物長寬高分別為 5 公尺、4 公尺及 1 公尺，若以高發泡局部放射泡沫滅火系統進行防護，依各類場所消防安全設備設…",{"webId":1242,"number":135,"stem":1243,"answer":69,"indexable":203},"fire-106-1-water-chemical-026","消防專用蓄水池至建築物各部分之水平距離，應在多少公尺以下？",{"webId":1245,"number":139,"stem":1246,"answer":43,"indexable":203},"fire-106-1-water-chemical-027","依各類場所消防安全設備設置標準，連結送水管之出水口設置，下列敘述何者錯誤？",{"webId":1248,"number":143,"stem":1249,"answer":33,"indexable":203},"fire-106-1-water-chemical-028","末端查驗管量測到的壓力為何？",{"webId":1251,"number":147,"stem":1252,"answer":43,"indexable":203},"fire-106-1-water-chemical-029","10 型乾粉滅火器乾粉充填量約為多少公斤重？",{"webId":1254,"number":151,"stem":1255,"answer":69,"indexable":203},"fire-106-1-water-chemical-030","第一種感度之撒水頭其反應時間指數（RTI）應小於多少 (ms) ？",{"webId":1257,"number":155,"stem":1258,"answer":48,"indexable":203},"fire-106-1-water-chemical-031","B-30 乾粉滅火器可以滅火之油盤面積為多少平方公尺？",{"webId":1260,"number":159,"stem":1261,"answer":43,"indexable":203},"fire-106-1-water-chemical-032","二氧化碳全區放射方式之安全裝置，啟動裝置開關或拉桿開始動作至儲存容器之容器閥開啟，設有多少秒以上之遲延裝置？",{"webId":1263,"number":163,"stem":1264,"answer":33,"indexable":203},"fire-106-1-water-chemical-033","二氧化碳局部放射方式依規定所核算之滅火藥劑量，應於多少秒內全部放射完畢？",{"webId":1266,"number":167,"stem":1267,"answer":69,"indexable":203},"fire-106-1-water-chemical-034","第一種乾粉滅火藥劑，全區放射方式所需滅火藥劑量為多少 kg\u002Fm ？",{"webId":1269,"number":171,"stem":1270,"answer":48,"indexable":203},"fire-106-1-water-chemical-035","乾式比濕式系統的撒水頭數量應追加百分之多少？",{"webId":1272,"number":299,"stem":1273,"answer":33,"indexable":203},"fire-106-1-water-chemical-036","低壓式二氧化碳噴頭之放射壓力為每平方公分多少公斤以上？",{"webId":1275,"number":175,"stem":1276,"answer":48,"indexable":203},"fire-106-1-water-chemical-037","消防幫浦之全閉揚程應為性能曲線上全揚程之百分之多少以下，方符合檢修基準要求？",{"webId":1278,"number":179,"stem":1279,"answer":43,"indexable":203},"fire-106-1-water-chemical-038","乾粉全區放射所核算之滅火藥劑量須於幾秒內放射完畢？",{"webId":1281,"number":183,"stem":1282,"answer":43,"indexable":203},"fire-106-1-water-chemical-039","泡沫滅火設備使用低發泡水成膜泡沫液，其泡沫 25%還原時間應在多少分鐘以上？",{"webId":1284,"number":187,"stem":1285,"answer":43,"indexable":203},"fire-106-1-water-chemical-040","有一長 15 公尺、寬 12 公尺及高 3 公尺之密閉空間裝置二氧化碳滅火設備，假設空氣中氧氣之體積百分率濃度為 21%，在…",[1287,1290,1292,1294,1296,1298,1300,1302,1304,1306],{"year":1288,"session":31,"count":37,"points":1289},115,50,{"year":1291,"session":31,"count":37,"points":1289},114,{"year":1293,"session":31,"count":37,"points":1289},113,{"year":1295,"session":31,"count":37,"points":1289},112,{"year":1297,"session":31,"count":37,"points":1289},111,{"year":1299,"session":31,"count":37,"points":1289},110,{"year":1301,"session":31,"count":37,"points":1289},109,{"year":1303,"session":31,"count":37,"points":1289},108,{"year":1305,"session":31,"count":37,"points":1289},107,{"year":1307,"session":31,"count":37,"points":1289},106,1785123154332]