[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-115-1-alarm-evacuation-030":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":51,"hasEssay":72},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-115-1-警報與避難系統消防安全設備概要-030","fire-115-1-alarm-evacuation-030",115,1,30,"關於緊急電源插座之設置位置，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"裝設於各居室中心，且任何一處至插座距離在 25 公尺以下","裝設於樓梯間或緊急昇降機間等處，且每一層任何一處至插座之水平距離在 50 公尺以下","裝設於走廊盡頭，且水平距離應在 100 公尺以下","僅限 11 層以上樓層設置，且距離樓梯須在 15 公尺以下","B",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-107-1-alarm-evacuation-029","依各類場所消防安全設備設置標準規定，有關標示設備之敘述，何者正確？",29,107,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-107-1-alarm-evacuation-031","依各類場所消防安全設備設置標準規定，公共危險物品製造場所及一般處理場所總樓地板面積在多少平方公尺以上者，應設置火警自動警報設備？",31,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-107-1-alarm-evacuation-028","依各類場所消防安全設備檢修及申報作業基準規定，對火警自動警報設備進行二信號性能檢查時，有關判定方法，下列敘述何者錯誤？",28,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-107-1-alarm-evacuation-032","依各類場所消防安全設備設置標準規定，下列何者非屬消防搶救上之必要設備種類？",32,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-107-1-alarm-evacuation-027","依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，緊急用電源回路及操作回路，應使用多少伏特耐熱絕緣電線，或同等耐熱效果以上之電線？",27,{"webId":48,"stem":49,"number":50,"year":30,"session":12},"fire-107-1-alarm-evacuation-033","依各類場所消防安全設備檢修及申報作業基準規定，檢查檢知器時，使用「加瓦斯試驗器」進行加瓦斯測試，對空氣之比重未滿一者應使用何種物質？",33,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-113-1-alarm-evacuation-030",113,"某建築物於第五層開設健身休閒中心，依法應設置排煙設備。惟於該場所內之衣帽間規劃免設排煙設備，試問符合下列何種條件方得免設？",{"webId":57,"year":58,"stem":59,"number":13},"fire-112-1-alarm-evacuation-030",112,"避難器具的固定架或支固器具使用螺栓固定時，若螺紋標稱為 M12×1.75 時，把螺栓埋入混凝土內不含灰漿部分之深度應為 X mm 以上，轉矩值應為 Y kgf-cm。X，Y 應各為多少？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-alarm-evacuation-030",111,"依各類場所消防安全設備設置標準規定，有關緊急廣播設備敘述下列何者錯誤？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-alarm-evacuation-030",110,"火警自動警報設備之緊急電源，其容量能使其有效動作 A 分鐘以上；緊急廣播設備之緊急電源，其容量能使其有效動作 B 分鐘以上，其中 A 及 B 分別為：",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-alarm-evacuation-030",109,"有關緊急廣播設備標示燈外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準規定相同？",true,1785129962028]