[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-115-1-alarm-evacuation-029":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":51,"hasEssay":72},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-115-1-警報與避難系統消防安全設備概要-029","fire-115-1-alarm-evacuation-029",115,1,29,"有關特別安全梯排煙室設置排煙、進風風管時，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"進風口應設於天花板下方 80 公分內，且進風量需達每秒 10 立方公尺","風管貫穿防火區劃時，貫穿處應增設手動關閉閘門","進風口及排煙口平時應保持開啟狀態，確保氣流流通","排煙口應位於天花板高度 1\u002F2 以上，且排煙量在每秒 4 立方公尺以上","D",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-107-1-alarm-evacuation-028","依各類場所消防安全設備檢修及申報作業基準規定，對火警自動警報設備進行二信號性能檢查時，有關判定方法，下列敘述何者錯誤？",28,107,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-107-1-alarm-evacuation-030","偵煙式探測器除光電式分離型外，下列裝置規定何者錯誤？",30,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-107-1-alarm-evacuation-027","依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，緊急用電源回路及操作回路，應使用多少伏特耐熱絕緣電線，或同等耐熱效果以上之電線？",27,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-107-1-alarm-evacuation-031","依各類場所消防安全設備設置標準規定，公共危險物品製造場所及一般處理場所總樓地板面積在多少平方公尺以上者，應設置火警自動警報設備？",31,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-107-1-alarm-evacuation-026","依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，有關電源回路之配線耐燃保護，若電線裝於金屬導線管槽內，並埋設於防火構造物之混凝土內，混凝土保護厚度應為多少毫米以上？",26,{"webId":48,"stem":49,"number":50,"year":30,"session":12},"fire-107-1-alarm-evacuation-032","依各類場所消防安全設備設置標準規定，下列何者非屬消防搶救上之必要設備種類？",32,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-113-1-alarm-evacuation-029",113,"有關特別安全梯與緊急昇降機間排煙室兼用時，其排煙設備採機械排煙、自然進風方式，則排煙機之排煙量應在 X m3\u002Fsec 以上；直接面向戶外之進風口開口面積應在 Y m2 以上則 X、Y 各為多少？",{"webId":57,"year":58,"stem":59,"number":13},"fire-112-1-alarm-evacuation-029",112,"某建築物總樓地板面積在 5 萬平方公尺以上其主要避難路徑的地方，該出口標示燈及避難方向指示燈之緊急電源容量應在 60 分鐘以上，下列場所何者不是主要避難路徑？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-alarm-evacuation-029",111,"緩降機為顧及使用之安全，裝置時應考慮之位置下列何者為佳？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-alarm-evacuation-029",110,"有關瓦斯漏氣檢知器之設置，當瓦斯對空氣之比重小於 1 時，應設於距瓦斯燃燒器具水平距離 A 公尺以內；當瓦斯對空氣之比重大於 1 時，應設於距瓦斯燃燒器具水平距離 B 公尺以內，其中 A 及 B 分別為：",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-alarm-evacuation-029",109,"有關瓦斯漏氣火警自動警報設備檢知器外觀檢查選取之檢查數量，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",true,1785129962021]