[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-115-1-alarm-evacuation-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":51,"hasEssay":72},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-115-1-警報與避難系統消防安全設備概要-025","fire-115-1-alarm-evacuation-025",115,1,25,"有關一般場所出口標示燈及避難方向指示燈之緊急電源，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"應使用發電機，容量 30 分鐘以上","應使用蓄電池設備，其容量應能使其有效動作 20 分鐘以上","應使用蓄電池，容量需達 60 分鐘且與火警分區共用","避難層以外之樓層可免設緊急電源","B",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-107-1-alarm-evacuation-024","P 型受信總機採用數個分區共用一公用線方式配線時，該公用線供應之分區數，依各類場所消防安全設備設置標準規定，不得超過多少個？",24,107,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-107-1-alarm-evacuation-026","依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，有關電源回路之配線耐燃保護，若電線裝於金屬導線管槽內，並埋設於防火構造物之混凝土內，混凝土保護厚度應為多少毫米以上？",26,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-107-1-alarm-evacuation-023","自居室任一點易於觀察識別其主要出入口，且與主要出入口之步行距離符合規定者，得免設出口標示燈、避難方向指示燈或避難指標，試問下列何者不得免設？",23,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-107-1-alarm-evacuation-027","依各類場所消防安全設備設置標準規定，緊急供電系統之配線除依屋內線路裝置規則外，緊急用電源回路及操作回路，應使用多少伏特耐熱絕緣電線，或同等耐熱效果以上之電線？",27,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-107-1-alarm-evacuation-022","依各類場所消防安全設備設置標準規定，火警自動警報設備之緊急電源，應使用蓄電池設備，其容量能使其有效動作多少分鐘以上？",22,{"webId":48,"stem":49,"number":50,"year":30,"session":12},"fire-107-1-alarm-evacuation-028","依各類場所消防安全設備檢修及申報作業基準規定，對火警自動警報設備進行二信號性能檢查時，有關判定方法，下列敘述何者錯誤？",28,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-113-1-alarm-evacuation-025",113,"依各類場所消防安全設備設置標準之規定，有關緊急電源插座之設置規定，下列敘述何者正確？",{"webId":57,"year":58,"stem":59,"number":13},"fire-112-1-alarm-evacuation-025",112,"有關發電機設備設置場所之外觀試驗，依據緊急電源（發電機設備）測試報告書判定要領，下列敘述何者錯誤？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-alarm-evacuation-025",111,"依 119 火災通報裝置認可基準規定，當常用電源停電，持續 X 分鐘待機狀態後，需保有 Y 分鐘以上可進行火災通報之電源容量；通話功能及回鈴應答試驗於 Z 秒內未收到回鈴信號，應可重複進行撥號。則 X、Y、Z 為何？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-alarm-evacuation-025",110,"下列有關火警受信總機之裝置規定，何者錯誤？",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-alarm-evacuation-025",109,"有關火焰式探測器之設置，下列何者與各類場所消防安全設備設置標準之規定不同？",true,1785129962004]