[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-114-1-fire-law-030":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-114-1-消防法規概要-030","fire-114-1-fire-law-030",114,1,30,"下列何者非屬各類場所消防安全設備設置標準之警報設備？",{"A":16,"B":17,"C":18,"D":19},"防災監控系統綜合操作裝置","一一九火災通報裝置","瓦斯漏氣火警自動警報設備","手動報警設備","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》對消防安全設備之分類，特別是警報設備與消防搶救上之必要設備之界線。\n【正解理由】依《各類場所消防安全設備設置標準》第 9 條，警報設備種類為火警自動警報設備、手動報警設備、緊急廣播設備、瓦斯漏氣火警自動警報設備、一一九火災通報裝置等五種；防災監控系統綜合操作裝置則列在第 11 條第六款，屬消防搶救上之必要設備，並非警報設備，故選 A。\n【逐項排除】\n(A) 防災監控系統綜合操作裝置：第 11 條第六款所列消防搶救上之必要設備，非第 9 條之警報設備，為本題應選之非屬者。\n(B) 一一九火災通報裝置：第 9 條第五款所列警報設備。\n(C) 瓦斯漏氣火警自動警報設備：第 9 條第四款所列警報設備。\n(D) 手動報警設備：第 9 條第二款所列警報設備。\n【記憶點】警報設備五種背成一串：火警自動警報、手動報警、緊急廣播、瓦斯漏氣火警自動警報、一一九火災通報裝置；綜合操作裝置歸在消防搶救上之必要設備那一條。","本題的骨架是《各類場所消防安全設備設置標準》總則的分類體系。第 7 條把消防安全設備分為五類：滅火設備指以水或其他滅火藥劑滅火之器具或設備；警報設備指報知火災發生之器具或設備；避難逃生設備指火災發生時為避難而使用之器具或設備；消防搶救上之必要設備指火警發生時消防人員從事搶救活動上必需之器具或設備；以及其他經中央主管機關認定之消防安全設備。分類的判準寫在定義裡：警報設備是「報知火災發生」給場所內的人，消防搶救上之必要設備則是供消防人員搶救活動使用。\n\n各類的細目再由後續條文展開。第 9 條列警報設備五種；第 11 條列消防搶救上之必要設備六種，依序為連結送水管、消防專用蓄水池、排煙設備（緊急昇降機間、特別安全梯間排煙設備、室內排煙設備）、緊急電源插座、無線電通信輔助設備、防災監控系統綜合操作裝置。防災監控系統綜合操作裝置之所以容易被誤認為警報設備，是因為它監控的對象裡就包含各種警報設備：依第 192-1 條第一項，它應設置於防災中心、中央管理室或值日室等經常有人之處所，並監控或操作火警自動警報設備之受信總機、瓦斯漏氣火警自動警報設備之受信總機、緊急廣播設備之擴大機及操作裝置、連結送水管之加壓送水裝置及與其送水口處之通話連絡、緊急發電機、常開式防火門之偵煙型探測器、室內消防栓與自動撒水與泡沫及水霧等滅火設備加壓送水裝置、乾粉與惰性氣體及鹵化烴等滅火設備、排煙設備等九項。它是「統合監控的操作介面」，不是報知火災的器具。\n\n應設場所也值得一併記。防災監控系統綜合操作裝置依第 30-1 條，應設於高層建築物、總樓地板面積在五萬平方公尺以上之建築物、總樓地板面積在一千平方公尺以上之地下建築物，以及其他經中央主管機關公告之供公眾使用之場所；其緊急電源依第 192-1 條第二項準用第 38 條規定，供電容量為二小時以上。一一九火災通報裝置依第 22-1 條，應設於第十二條第一款第六目所定醫院、療養院、榮譽國民之家等場所，以及其他經中央主管機關公告之供公眾使用之場所；緊急廣播設備則依第 22 條，設有火警自動警報或瓦斯漏氣火警自動警報設備之建築物即應設置。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-114-1-fire-law-029","依各類場所消防安全設備設置標準規定，下列何處所得免設排煙設備？",29,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-114-1-fire-law-031","依消防法相關規定，下列敘述何者正確？",31,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-114-1-fire-law-028","依各類場所消防安全設備設置標準規定，二氧化碳滅火設備全區及局部放射方式之緊急電源，應採用自用發電設備或蓄電池設備，其容量應能使該設備有效動作多少時間以上？",28,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-114-1-fire-law-032","依可燃性高壓氣體場所標示板規格及設置要點規定，下列敘述何者錯誤？",32,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-114-1-fire-law-027","依各類場所消防安全設備設置標準，針對滅火設備水源容量之規定，下列敘述何者錯誤？",27,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-114-1-fire-law-033","依六類公共危險物品製造儲存及處理場所標示板規格及設置要點規定，下列敘述何者正確？",33,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-fire-law-030",113,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準規定，對於電動機之構造與機能，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-law-030",112,"依消防安全設備及必要檢修項目檢修基準之規定，有關惰性氣體滅火設備之綜合檢查，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-030",111,"依各類場所消防安全設備設置標準規定，某樓層高度超過 10 公尺且樓地板面積在 700 平方公尺以上之高架儲存倉庫，其撒水頭設置應符合之規定，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-030",110,"可燃性高壓氣體儲存場所防爆牆分為鋼筋混凝土製、混凝土空心磚製及鋼板製等三種，並應設置於堅固基礎上，強度應能承受可能預料之氣體爆炸衝擊，有關混凝土空心磚製防爆牆之規定，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-030",109,"依各類場所消防安全設備檢修及申報作業基準，有關避難器具外觀檢查之規定，緩降機下降空間之判定，在無其他突出物干擾的情境下，以器具中心半徑多少公分的圓柱形範圍內，為緩降機的下降空間？",1785129968694]