[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-114-1-fire-law-024":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-114-1-消防法規概要-024","fire-114-1-fire-law-024",114,1,24,"依避難器具支固器具及固定部之結構、強度計算及施工方法規定，有關斜降式救助袋之下部支撐裝置固定在降落面等器具之構造、強度及埋設到降落面之方法，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"固定器具需設在具有蓋子之箱子內部，設置可輕易鉤到下部支撐裝置大小之環或橫棒","固定橫棒需具備足夠寬度使下部支撐裝置之鉤子可輕易鉤住，且有防止拉拔措施","蓋子在使用時，其結構應可輕易打開，為防止遺失並應有鍊條連接，且其表面應以不易磨滅方式標示救助袋設置之樓層","固定部展開救助袋時，與降落面角度約為 45 度","D",null,[],false,"本題考點：《避難器具支固器具及固定部之結構、強度計算及施工方法》第七點，斜降式救助袋下部支撐裝置固定器具之構造、強度及埋設方法。\n【正解理由】依《避難器具支固器具及固定部之結構、強度計算及施工方法》第七點，就固定器具埋設在降落面之場所明定「固定部展開救助袋時，與降落面角度約為三十五度」，並應設置於能讓袋子完全展開之避難空地上，且不可設置於可能會被土石掩埋之場所、設置時不得妨礙通行。本項寫四十五度，與該規定之三十五度不符，故選 D。\n【逐項排除】\n(A) 同點就固定器具之構造明定，固定器具需設在具有蓋子之箱子內部，設置可輕易鉤到下部支撐裝置大小之環或橫棒，本項與原文一致。\n(B) 同點就固定橫棒明定，需具備足夠寬度使下部支撐裝置之鉤子可輕易鉤住，其兩端須以九十度往垂直方向彎曲，對降落面需充分埋入具備表列拉伸荷重，且有防止拉拔措施，本項正確。\n(C) 同點就箱子與蓋子明定，蓋子在使用時其結構應可輕易打開，為防止遺失並應有鍊條連接，且其表面應以不易磨滅方式標示救助袋設置之樓層，本項正確。\n(D) 展開角度之數值為三十五度，本項誤為四十五度，為錯誤敘述。\n【記憶點】斜降式救助袋固定部展開時與降落面角度約三十五度；四十五度出自《消防安全設備測試報告書測試方法及判定要領》第十二章避難器具之外觀試驗，該處所定為斜降式救助袋伸展時對水平樓地板面應有大約四十五度之長度。","《避難器具支固器具及固定部之結構、強度計算及施工方法》是避難器具「裝得牢不牢」的技術規定，全文依壹設計載重、貳支固器具構造及強度、參支固器具之固定方式、肆施工基準、伍避難器具用升降口施工方法等順序展開，第七點專講斜降式救助袋下部支撐裝置固定在降落面之器具。\n固定環的規格與荷重是本點的核心：固定環等應為直徑十六毫米以上之 CNS 3270 不銹鋼棒或具同等以上強度及耐蝕措施者，並需確實埋入降落面、能承受表八之拉伸荷重，且有防止固定環脫離之有效措施。表八依袋長分四級：袋長十五公尺以下者二八五公斤重、超過十五在三十以下者五二五公斤重、超過三十在四十以下者六四五公斤重、超過四十者七五○公斤重，荷重方向均為仰角二十五度。箱子與蓋子則須具有能耐車輛等通行之積載荷重強度，並符合 CNS 2472 灰口鑄鐵件規定或具同等以上耐蝕性能，內部應採有效排水措施，大小需能方便清潔內部。\n這幾個角度數值容易互相干擾，宜整組並列記憶：本規定第七點的固定部展開角度約三十五度；表一設計載重就斜降式救助袋所定之荷重方向為上端部分俯角七十度、下端部分仰角二十五度；《設置標準》第一百六十四條與檢修基準第十八章避難器具外觀檢查所定之下降空間，斜降式救助袋為救助袋下方及側面在上端二十五度、下端三十五度方向所圍範圍內。\n相關考點還包括《設置標準》第一百六十三條之操作面積：救助袋為寬一百五十公分以上、長一百五十公分以上（含器具所佔面積），但無操作障礙且操作面積在二點二五平方公尺以上時不在此限；緩降機、避難梯、避難繩索及滑杆則為零點五平方公尺以上（不含避難器具所佔面積），邊長應為六十公分以上。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-114-1-fire-law-023","依消防設備人員法規定，下列敘述何者錯誤？",23,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-114-1-fire-law-025","依消防設備人員法規定，有關消防設備人員的業務及責任，下列敘述何者錯誤？",25,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-114-1-fire-law-022","消防設備人員依消防安全設備及必要檢修項目檢修基準規定，執行室內消防栓設備檢修之綜合檢查。下列檢查方法及判定方法，何者錯誤？",22,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-114-1-fire-law-026","依據消防法、公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關公共危險物品管制量規定，下列敘述何者錯誤？",26,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-114-1-fire-law-021","某工廠現有建築物及儲存場所之中度危險工作場所樓地板面積合計 2,000 平方公尺，該工廠將擴廠增建一棟一樓層之低度危險工作場所，該增建場所之建築物及儲存場所樓地板面積合計在多少平方公尺以上時，應設置室外消防栓設備？",21,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-114-1-fire-law-027","依各類場所消防安全設備設置標準，針對滅火設備水源容量之規定，下列敘述何者錯誤？",27,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-fire-law-024",113,"有關避難器具支固器具及固定部之結構、強度計算及施工方法之規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-law-024",112,"某一消防設備士受託辦理一家辦公大樓消防安全設備檢修，該大樓依規定設置之全部緩降機經消防設備士執行下降檢查，測量每具緩降機之下降距離及下降時間，經計算出之平均下降速度全部符合規定，其緩降機之下降距離及下降時間，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-024",111,"某室外儲槽場所儲槽儲存第四類公共危險物品，儲槽容量合計為 25 萬公秉，防液堤高度應在多少公尺以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-024",110,"依各類場所消防安全設備設置標準規定，有關連結送水管之送水設計壓力規定計算，下列敘述何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-024",109,"依各類場所消防安全設備設置標準之規定，有一容納超過 300 人老人福利機構餐廳，其樓地板面積在多少平方公尺以上，廚房排油煙管及煙罩即應裝設簡易自動滅火裝置？",1785129968650]