[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-114-1-fire-law-018":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-114-1-消防法規概要-018","fire-114-1-fire-law-018",114,1,18,"依各類場所消防安全設備設置標準規定，下列何者為有效開口之必要條件？",{"A":16,"B":17,"C":18,"D":19},"開口下端距樓地板面 140 公分以內","開口下端距樓地板面 120 公分以內","開口下端距樓地板面 100 公分以內","開口下端距樓地板面 80 公分以內","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第四條所定「有效開口」之要件，考的是開口下端距樓地板面之法定高度。\n【正解理由】依《各類場所消防安全設備設置標準》第四條第二項，該條第一項第二款無開口樓層所稱之有效開口，指符合下列四款者：一、開口下端距樓地板面一百二十公分以內；二、開口面臨道路或寬度一公尺以上之通路；三、開口無柵欄且內部未設妨礙避難之構造或阻礙物；四、開口為可自外面開啟或輕易破壞得以進入室內之構造，採一般玻璃門窗時，厚度應在六毫米以下。條文就開口下端與樓地板面之距離只寫一個數值，即一百二十公分以內，故選 B。\n【逐項排除】\n(A) 一百四十公分：四款要件中並無此數值，與第四條第二項第一款所定之一百二十公分不符。\n(B) 一百二十公分以內：逐字見於第四條第二項第一款，為有效開口四款要件之首款，本項正確。\n(C) 一百公分：條文所定之數值為一百二十公分，本項自行改寫了法定門檻。\n(D) 八十公分：四款要件中同樣沒有這個數值，本項並非有效開口之法定條件。\n【記憶點】有效開口四要件：下端一百二十公分以內、面臨道路或一公尺以上通路、無柵欄且內部無避難障礙、可自外面開啟或破壞進入（一般玻璃門窗六毫米以下）。","《設置標準》第四條是全篇的用語定義條，「無開口樓層」與「有效開口」必須連著讀。同條第一項第二款先以有效開口面積是否達樓地板面積三十分之一界定無開口樓層，並分十一層以上之樓層與十層以下之樓層兩目；十層以下之樓層除面積比例外，另要求其中至少應具有二個內切直徑一公尺以上圓孔，或寬七十五公分以上、高一百二十公分以上之開口。第二項才回頭界定何謂有效開口，也就是本題所考的四款要件。\n值得注意的是「一百二十公分」在同一條出現兩次而意義不同：一次是第一項第二款十層以下樓層之開口「高一百二十公分以上」，講的是開口尺寸；一次是第二項第一款有效開口之「開口下端距樓地板面一百二十公分以內」，講的是開口位置。一個問開口多大、一個問開口多高，混用就會失分。\n記憶上可把四款要件排成四拍：一百二十公分是下端高度、一公尺是通路寬度、第三款要求無柵欄且內部未設妨礙避難之構造或阻礙物、第四款要求可自外面開啟或輕易破壞得以進入室內，採一般玻璃門窗時厚度應在六毫米以下。四款是並列要件，缺一即非有效開口。\n無開口樓層一經認定，會牽動多條應設場所規定：第十五條第一項第四款對地下層或無開口之樓層另定一百平方公尺（供第十二條第一款第一目所列場所使用者）或一百五十平方公尺之門檻；第十七條第一項第三款、第十九條第一項第四款、第二十八條第一項第三款也各自對無開口樓層設有專款。此外，第四條第三項明定本標準所列有關建築技術用語，適用建築技術規則之定義，因此本條定義題常與建築用語題合併命題。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-114-1-fire-law-017","依消防安全設備及必要檢修項目檢修基準規定，針對性能檢查完成後之滅火器應張貼標示，下列敘述何者錯誤？",17,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-114-1-fire-law-019","依各類場所消防安全設備設置標準規定，下列何者應就水霧、泡沫、乾粉、二氧化碳滅火設備等選擇設置？",19,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-114-1-fire-law-016","依消防安全設備及必要檢修項目檢修基準規定，有關火警自動警報設備綜合檢查，下列敘述何者錯誤？",16,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-114-1-fire-law-020","依建築技術規則建築設計施工編規定，下列敘述何者錯誤？",20,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-114-1-fire-law-015","依消防安全設備及必要檢修項目檢修基準規定，有關連結送水管性能，水帶箱水帶的檢查及判定，下列敘述何者錯誤？",15,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-114-1-fire-law-021","某工廠現有建築物及儲存場所之中度危險工作場所樓地板面積合計 2,000 平方公尺，該工廠將擴廠增建一棟一樓層之低度危險工作場所，該增建場所之建築物及儲存場所樓地板面積合計在多少平方公尺以上時，應設置室外消防栓設備？",21,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-fire-law-018",113,"依消防法第 11 條第 1 項規定，地面樓層達 11 層以上建築物、地下建築物及中央主管機關指定之場所，其管理權人應使用附有防焰標示之地毯、窗簾、布幕、展示用廣告板及其他指定之防焰物品。關於上開規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-law-018",112,"依各類場所消防安全設備設置標準之規定，下列何類場所非屬應設置一一九火災通報裝置之場所？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-018",111,"下列何者非經中央主管建築機關認定符合耐燃一級之「不因火熱引起燃燒、熔化、破裂變形及產生有害氣體」之材料？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-018",110,"第一種室內消防栓與室外消防栓之比較，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-018",109,"有一固態酒精儲槽水平剖面半徑為 10 公尺，依防火牆及防火水幕設置基準，其假想火面高度應為多少公尺？",1785129968609]