[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-114-1-fire-law-010":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-114-1-消防法規概要-010","fire-114-1-fire-law-010",114,1,10,"依消防安全設備檢修及申報辦法規定，管理權人報請場所所在地主管機關審核同意，得免定期辦理消防安全設備檢修及申報，下列何者非屬應檢具報審之文件？",{"A":16,"B":17,"C":18,"D":19},"因違反相關法規，經有關機關採取停止供水、供電或封閉等措施","建築物於避難層開向屋外之出入口及車輛出入口均已全日上鎖或封閉，且各出入口明顯處所張貼禁止進入之告示","整棟建築物自主安全管理措施","消防防護計畫","D",null,[],false,"本題考點：《消防安全設備檢修及申報辦法》第 11 條第 2 項所列，報請審核同意免定期檢修申報應檢具之文件。\n【正解理由】依《消防安全設備檢修及申報辦法》第 11 條第 2 項，管理權人應檢具下列文件報請場所所在地主管機關審核同意後，始得免定期辦理消防安全設備檢修及申報：申請書、建築物所有權狀影本、管理權人身分證明文件影本、符合前項第一款及第二款狀態之一之證明文件或照片、整棟建築物自主安全管理措施、其他經中央主管機關公告之文件。消防防護計畫並不在這六款之內，故選 D。\n【逐項排除】\n(A) 「因違反相關法規，經有關機關採取停止供水、供電或封閉等措施」為同條第 1 項第 1 款第 3 目之使用狀態，屬第 2 項第 4 款所稱應檢具之證明文件範圍。\n(B) 「建築物於避難層開向屋外之出入口及車輛出入口均已全日上鎖或封閉，且各出入口明顯處所張貼禁止進入之告示」為同條第 1 項第 2 款第 1 目之管理狀態，同屬第 2 項第 4 款之證明範圍。\n(C) 「整棟建築物自主安全管理措施」逐字列於第 2 項第 5 款。\n(D) 消防防護計畫係《消防法》第 13 條防火管理制度下之文書，不在第 11 條第 2 項六款之列，故為非屬應檢具者。\n【記憶點】免定期申報備文件是申請書、權狀、身分證明、狀態證明、自主安全管理措施加公告文件，沒有消防防護計畫。","《消防安全設備檢修及申報辦法》第 11 條是《消防法》第 9 條第 1 項但書的下位規範，第 1 項定認定基準、第 2 項定應備文件，兩項要分層記。第 1 項把「整棟已無使用」拆成兩組要件，各須符合其中之一：使用狀態四目為建築物內部之場所均已歇業、停業或現場無實際使用情形，因地震、水災、風災、火災或其他重大事變致建築物毀損無法使用，因違反相關法規經有關機關採取停止供水、供電或封閉等措施，其他經場所所在地主管機關認定已無使用之情形；管理狀態三目為建築物於避難層開向屋外之出入口及車輛出入口均已全日上鎖或封閉且各出入口明顯處所張貼禁止進入之告示，整棟建築物之建築基地周圍設置圍籬予以封閉且於明顯處所張貼禁止進入之告示，其他經場所所在地主管機關認定建築物已封閉之情形。\n第 2 項六款文件中，第 4 款正是「符合前項第一款及第二款狀態之一之證明文件或照片」，所以本題的停止供水供電封閉、出入口上鎖並張貼告示這兩個敘述，其實是第 1 項的要件內容，它們是被證明的對象，透過第 4 款進入應備文件；而整棟建築物自主安全管理措施則是自己獨立成一款。命題者把三個來自不同層級卻都真實存在的項目與一個不存在的項目並列，考的就是能否把第 1 項與第 2 項對應起來。\n消防防護計畫屬另一條軌道。依《消防法》第 13 條，一定規模以上之建築物應由管理權人遴用防火管理人，責其訂定消防防護計畫；建築物遇有增建、改建、修建、變更使用或室內裝修施工致影響原有系統式消防安全設備功能時，應另定施工中消防防護計畫；管理權有分屬情形者，各管理權人應協議遴用共同防火管理人並訂定共同消防防護計畫。上開計畫均應報請建築物所在地主管機關備查。防火管理管的是人的組織與應變，消防安全設備檢修申報管的是設備的定期檢查與申報，兩者法源、主管程序都不同，免定期檢修申報之審核自然不以消防防護計畫為應備文件。\n附帶區辨兩種免除：第 11 條是「至該建築物恢復使用前」的長期免除，第 12 條則是取得使用執照、變更使用執照或室內裝修許可等證明文件後，甲類場所距申報期限六個月以內、甲類以外場所一年以內之當次免除。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-114-1-fire-law-009","依消防法、消防安全設備檢修及申報辦法規定，下列敘述何者正確？",9,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-114-1-fire-law-011","下列何者非屬開業建築師、電機技師得執行之消防安全設備設計、監造或測試、檢修？",11,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-114-1-fire-law-008","依消防安全設備設計監造測試及檢修作業辦法，消防設備人員對於所製作完成之檢修報告書，下列敘述何者正確？",8,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-114-1-fire-law-012","消防設備人員辦理各項業務，應遵守誠信原則，違反下列何項行為，可予以警告、申誡、停止執行業務 2 個月以上 2 年以下或廢止執業執照之懲戒處分：",12,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-114-1-fire-law-007","依消防設備人員法規定，下列敘述何者錯誤？",7,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-114-1-fire-law-013","消防設備人員執行消防安全設備之設計、監造、測試及檢修業務，由消防安全設備設計人員依滅火設備、警報設備、避難逃生設備、消防搶救上之必要設備及其他經中央主管機關認定之消防安全設備等依序繪製，標示記號，並依消防或建築等圖示範例註記，上述製作之文書為下列何者？",13,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-fire-law-010",113,"依各類場所消防安全設備設置標準規定，有關設置於公共危險物品等場所之自動撒水設備，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-law-010",112,"某一亞硝酸鹽類之製造場所設有符合規定之擋牆防護，依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，其外牆或相當於該外牆之設施外側，與廠區外鄰近之圖書館的安全距離至少應為多少公尺以上？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-010",111,"依各類場所消防安全設備檢修期限及申報備查期限，下列敘述何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-010",110,"公共危險物品等場所之滅火設備共分為五大類，其中第五種滅火設備係指滅火器、水桶、水槽、乾燥砂、膨脹蛭石或膨脹珍珠岩等，除滅火器外之其他設備，有關核算滅火效能值，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-010",109,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，室內儲槽場所之儲槽專用室出入口，應設置多少公分以上之門檻，或設置具有同等以上效能之防止流出措施？",1785129968561]