[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-114-1-alarm-evacuation-036":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":51,"hasEssay":72},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-114-1-警報與避難系統消防安全設備概要-036","fire-114-1-alarm-evacuation-036",114,1,36,"購物中心之挑高空間高度 18 公尺，設有 skylight 採光天窗，火警探測器之設置何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"採用光電式局限型偵煙探測器應選用第一種，裝置高度需考慮層流效應之影響","採用火焰探測器時，裝置時應避免陽光直射或室內裝修金屬板之陽光反射","採用光電分離式偵煙探測器時，裝置高度在天花板等高度百分之八十以下之位置","採用光電式分離式偵煙探測器應選用第一種","C",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-106-1-alarm-evacuation-035","執行檢修時，在室溫 15℃狀態下，使用加熱試驗器進行差動式局限型第二種探測器之性能檢查時，其動作時間應在多少秒內方為正常？",35,106,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-106-1-alarm-evacuation-037","為避免探測死角，在安裝光電式分離型探測器時，其受光器及送光器應設在距其背部牆壁多少公分範圍內？",37,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-106-1-alarm-evacuation-034","在裝設定溫式感知線型探測器場所，進行回路合成阻抗試驗時，會使用下列何種檢查儀器？",34,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-106-1-alarm-evacuation-038","依各類場所消防安全設備設置標準規定，避難指標設於出入口裝設應距樓地板面的高度要求為多少？",38,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-106-1-alarm-evacuation-033","針對某百貨公司美食街進行檢修，下列何項試驗必須使用加瓦斯試驗器，使兩個回路之任一檢知器（各回路一個）同時動作，以確認其性能是否異常？",33,{"webId":48,"stem":49,"number":50,"year":30,"session":12},"fire-106-1-alarm-evacuation-039","具有效採光，且直接面向室外之通道或走廊居室得免設緊急照明；所謂有效採光面積應達該居室樓地板面積多少比率方得免設？",39,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-113-1-alarm-evacuation-036",113,"依住宅用火災警報器設置辦法規定，住宅用火災警報器應安裝於寢室、廚房、樓梯。若非屬前三類處所且任一樓層有超過 X 平方公尺之居室達 Y 間以上者，則設於走廊。則 X、Y 分別為何？",{"webId":57,"year":58,"stem":59,"number":13},"fire-112-1-alarm-evacuation-036",112,"依消防安全設備及必要檢修項目檢修基準，有關火警自動警報設備偵煙探測器局限型，其性能檢查的敘述，下列何者正確？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-alarm-evacuation-036",111,"探測器安裝與天花板冷氣出風口應保持適當之距離，與火警探測器認可基準之下列何者有關？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-alarm-evacuation-036",110,"某場所第五層需設置排煙設備，樓地板面積為 1200 平方公尺並區分為 450、400 及 350 平方公尺等三個防煙區劃，試問該層排煙機之排煙量最少應為每分鐘多少立方公尺？",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-alarm-evacuation-036",109,"有關定溫式感知線型探測器之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",true,1785129962395]