[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-114-1-alarm-evacuation-031":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":51,"hasEssay":72},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-114-1-警報與避難系統消防安全設備概要-031","fire-114-1-alarm-evacuation-031",114,1,31,"有關一一九火災通報裝置設置規定，何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"醫院所設置之一一九火災通報裝置應設於值日室，並優先設於防災中心","遠端啟動裝置可提供人員於現場確認火災後，即時啟動便可自動通報消防局","設有電話內線系統時應相互連結以方便轉接至各層分機，接聽消防局確認來電","手動啟動裝置之操作開關距離樓地板面之高度在 0.8 公尺以上 1.5 公尺以下","C",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-106-1-alarm-evacuation-030","在某飯店檢查瓦斯漏氣火警自動警報設備時，何項試驗必須切換成緊急電源之狀態？",30,106,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-106-1-alarm-evacuation-032","針對瓦斯漏氣火警自動警報設備進行性能檢查，使用噪音計進行瓦斯漏氣檢知區域警報裝置之音量檢測時，距離警報裝置 1 公尺處，其音壓量應在多少分貝以上方為合格？",32,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-106-1-alarm-evacuation-029","瓦斯濃度達到警報濃度值後，其濃度仍繼續存在，即發出警報，但瓦斯洩漏濃度越高，則警報延遲動作時間越短，此種檢知瓦斯之警報發出方式稱作何種型式？",29,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-106-1-alarm-evacuation-033","針對某百貨公司美食街進行檢修，下列何項試驗必須使用加瓦斯試驗器，使兩個回路之任一檢知器（各回路一個）同時動作，以確認其性能是否異常？",33,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-106-1-alarm-evacuation-028","大型建築物警報設備使用許多中繼器來連結探測器與受信總機，但下列何者不是警報設備中繼器主要功能？",28,{"webId":48,"stem":49,"number":50,"year":30,"session":12},"fire-106-1-alarm-evacuation-034","在裝設定溫式感知線型探測器場所，進行回路合成阻抗試驗時，會使用下列何種檢查儀器？",34,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-113-1-alarm-evacuation-031",113,"避難器具於竣工查驗時，針對固定架或支固器具使用螺栓固定實施性能試驗，為確認螺栓對拉出之耐力，進行拉拔強度試驗。今使用直徑 10 毫米錨定螺栓，設計拉拔荷重（試驗荷重）為 960 公斤力（kgf），使用扭力扳手作為測定拉拔荷重之器具時，則鎖緊扭力應為多少公斤力-公分（kgf．cm）？",{"webId":57,"year":58,"stem":59,"number":13},"fire-112-1-alarm-evacuation-031",112,"依消防安全設備及必要檢修項目檢修基準，執行緊急廣播設備性能檢查時，對啟動裝置狀態於檢查後判定方法，下列敘述何者錯誤？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-alarm-evacuation-031",111,"設置 119 火災通報裝置的主要功能為何？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-alarm-evacuation-031",110,"一一九火災通報裝置，下列規定何者正確？",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-alarm-evacuation-031",109,"有關緊急照明設備性能檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",true,1785129962349]