[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-114-1-alarm-evacuation-017":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":51,"hasEssay":72},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-114-1-警報與避難系統消防安全設備概要-017","fire-114-1-alarm-evacuation-017",114,1,17,"有關火警自動警報設備的差動式分布型探測器，依各類場所消防安全設備設置標準規定何者正確？",{"A":16,"B":17,"C":18,"D":19},"差動式分布型探測器為空氣管式時，裝接於 1 個檢出器之空氣管長度，在 120 公尺以下","差動式分布型探測器為熱電偶式時，裝接於 1 個檢出器之熱電偶數，為 2 個以上 15 個以下","差動式分布型探測器為熱半導體式時，裝接於 1 個檢出器之感熱器數量，在 4 個以上 20 個以下","空氣管裝置、熱電偶式、熱半導體式探測器設在裝置面下方 30 公分範圍內","D",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-106-1-alarm-evacuation-016","瓦斯漏氣火警自動警報設備裝置於瓦斯對空氣之比重未滿一之建築物室內時，檢知器設置位置應距瓦斯燃燒器具或瓦斯導管貫穿牆壁處水平距離多少以內？",16,106,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-106-1-alarm-evacuation-018","依各類場所消防安全設備檢修及申報作業基準規定，火焰探測器以動作試驗器確認探測器之動作應在多少時間內方為合格？",18,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-106-1-alarm-evacuation-015","依緩降機認可基準規定，緩降機之最大使用載重，應在最大使用人數乘以 W 所得數值以上。下述 W 值何者正確？",15,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-106-1-alarm-evacuation-019","一居室設置於地上層，該樓層亦非為無開口樓層，自內部任一點易於識別主要出入口，主要出入口之步行距離在多少以下者，得免設避難方向指示燈？",19,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-106-1-alarm-evacuation-014","依各類場所消防安全設備檢修及申報作業基準規定，火警自動警報設備之受信總機前應確保多少公尺以上空間以進行檢查及操作使用？",14,{"webId":48,"stem":49,"number":50,"year":30,"session":12},"fire-106-1-alarm-evacuation-020","差動式探測器之動作原理為感應火場中何種參數？",20,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-113-1-alarm-evacuation-017",113,"電子工業廠房潔淨區，因潔淨環境及構造特殊，特訂定潔淨區消防安全設備設置要點，對於潔淨室設置吸氣式偵煙探測系統時，依據此設置要點，下列說明何者錯誤？",{"webId":57,"year":58,"stem":59,"number":13},"fire-112-1-alarm-evacuation-017",112,"有一地下建築物總樓地板面積超過 1 千平方公尺，依據各類場所消防安全設備設置標準，下列何者非依法應設之消防安全設備？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-alarm-evacuation-017",111,"下列何者非各類場所消防安全設備設置標準明定應設置防災監控系統綜合操作裝置之場所？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-alarm-evacuation-017",110,"下列那二種避難器具在性能檢查時，均須對其下降空地附近之支持或固定裝置進行判定？",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-alarm-evacuation-017",109,"一一九火災通報裝置之設置規定，下列敘述何者錯誤？",true,1785129962236]