[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-114-1-alarm-evacuation-016":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":25,"sameNumber":51,"hasEssay":72},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":24,"freq":12,"indexable":23},"fire-114-1-警報與避難系統消防安全設備概要-016","fire-114-1-alarm-evacuation-016",114,1,16,"依各類場所消防安全設備設置標準，出口標示燈及避難方向指示燈之緊急電源之設置規定，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"總樓地板面積在 1 萬平方公尺以上高層建築物，通往直通樓梯之出入口的出口標示燈，該緊急電源容量應在 60 分鐘以上","地下建築物，其總樓地板面積在 1 千平方公尺以上者，由室內往走廊或通道之出入口標示燈，該緊急電源容量應在 60 分鐘以上","總樓地板面積在 5 萬平方公尺以上建築物的直通樓梯，其避難方向指示燈之緊急電源容量應在 60 分鐘以上","樓高在 100 公尺以上建築物，總樓地板面積在 1 萬平方公尺以上，通往直通樓梯之出入口的避難方向指示燈，該緊急電源容量應在 60 分鐘以上","C",null,[],false,"",[26,31,35,39,43,47],{"webId":27,"stem":28,"number":29,"year":30,"session":12},"fire-106-1-alarm-evacuation-015","依緩降機認可基準規定，緩降機之最大使用載重，應在最大使用人數乘以 W 所得數值以上。下述 W 值何者正確？",15,106,{"webId":32,"stem":33,"number":34,"year":30,"session":12},"fire-106-1-alarm-evacuation-017","檢查緩降機性能時，有關常溫下降試驗之判定中，緩降機最大下降速度應在多少以內？",17,{"webId":36,"stem":37,"number":38,"year":30,"session":12},"fire-106-1-alarm-evacuation-014","依各類場所消防安全設備檢修及申報作業基準規定，火警自動警報設備之受信總機前應確保多少公尺以上空間以進行檢查及操作使用？",14,{"webId":40,"stem":41,"number":42,"year":30,"session":12},"fire-106-1-alarm-evacuation-018","依各類場所消防安全設備檢修及申報作業基準規定，火焰探測器以動作試驗器確認探測器之動作應在多少時間內方為合格？",18,{"webId":44,"stem":45,"number":46,"year":30,"session":12},"fire-106-1-alarm-evacuation-013","集合住宅計算收容人數以設置避難器具時，每戶收容人數以多少人計算？",13,{"webId":48,"stem":49,"number":50,"year":30,"session":12},"fire-106-1-alarm-evacuation-019","一居室設置於地上層，該樓層亦非為無開口樓層，自內部任一點易於識別主要出入口，主要出入口之步行距離在多少以下者，得免設避難方向指示燈？",19,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-113-1-alarm-evacuation-016",113,"依防災監控系統綜合操作裝置認定基準，下列那一部分非防災監控系統綜合操作裝置構成？",{"webId":57,"year":58,"stem":59,"number":13},"fire-112-1-alarm-evacuation-016",112,"有關光電式分離型探測器設置規定，依據各類場所消防安全設備設置標準，下列敘述何者錯誤？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-alarm-evacuation-016",111,"依各類場所消防安全設備設置標準規定，下列何種場所得免設排煙設備？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-alarm-evacuation-016",110,"建築物之避難器具設置緩降機時，對其開口部進行外觀檢查之判定，下列何者合格？",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-alarm-evacuation-016",109,"防煙壁為自天花板下垂 X 公分以上之垂壁，但地下建築物之地下通道，防煙壁應自天花板下垂 Y 公分以上，其中 X、Y 分別為：",true,1785129962221]