[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-113-1-water-chemical-012":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-水與化學系統消防安全設備概要-012","fire-113-1-water-chemical-012",113,1,12,"自動撒水設備進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"密閉式撒水設備檢查方法切換成緊急電源供電狀態，然後於最遠支管末端，打開查驗閥，確認系統性能是否正常","開放式撒水設備檢查方法切換成緊急電源供電狀態，然後於最遠一區，確認性能是否正常","補助撒水栓檢查方法切換成緊急電源狀況，用任一補助撒水栓確認其操作性能是否正常","補助撒水栓測量瞄子直線放水壓力時應在每平方公分 1.5 公斤以上每平方公分 11 公斤以下","D",null,[],false,"本題考點：自動撒水設備綜合檢查之判定值，考補助撒水栓的放水壓力範圍。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》自動撒水設備綜合檢查之補助撒水栓，判定方法明定放水壓力應在 2.5kgf\u002Fcm2 以上 10kgf\u002Fcm2 以下、放水量應在 60 l\u002Fmin 以上，幫浦方式與重力水箱、壓力水箱方式同此數值。題敘寫成 1.5kgf\u002Fcm2 以上 11kgf\u002Fcm2 以下，上下限均與規定不符，故選 D。\n【逐項排除】\n(A) 正確。密閉式撒水設備之檢查方法為切換成緊急電源供電狀態，然後於最遠支管末端打開查驗閥，確認系統性能是否正常。\n(B) 正確。開放式撒水設備之檢查方法為切換成緊急電源供電狀態，然後於最遠一區，依關閉一齊開放閥二次側止水閥等步驟確認性能是否正常。\n(C) 正確。補助撒水栓之檢查方法為切換成緊急電源狀況，用任一補助撒水栓確認其操作性能是否正常。\n(D) 錯誤。放水壓力應在 2.5kgf\u002Fcm2 以上 10kgf\u002Fcm2 以下，即本題所指之錯誤敘述。\n【記憶點】補助撒水栓 2.5 至 10、60 l\u002Fmin；密閉式末端查驗管 1 至 10。","補助撒水栓的數值可以回到《各類場所消防安全設備設置標準》第五十七條核對：免設撒水頭處所得設置補助撒水栓，各層任一點至水帶接頭之水平距離在十五公尺以下；設有補助撒水栓之任一層，以同時使用該層所有補助撒水栓時，各瞄子放水壓力在每平方公分二點五公斤以上或 0.25MPa 以上，放水量在每分鐘六十公升以上。設置端的二點五公斤與六十公升，就是檢修端判定值的下限；上限十公斤則來自加壓送水裝置的減壓要求，第五十八條第二項明定撒水頭放水壓力應在每平方公分十公斤以下或 1MPa 以下，檢修基準性能檢查的減壓措施欄也是撒水頭 1kgf\u002Fcm2 以上 10kgf\u002Fcm2 以下、補助撒水栓 2.5kgf\u002Fcm2 以上 10kgf\u002Fcm2 以下。\n三種撒水設備的綜合檢查形狀不同，值得整組記。密閉式看末端查驗閥，判定放水壓力 1kgf\u002Fcm2 以上 10kgf\u002Fcm2 以下，並應設有與撒水頭同等放水性能之限流孔，其配置依第五十六條設於各流水檢知裝置配管系統中放水壓力最低之最遠支管末端、管徑二十五毫米以上、距地板面高度二點一公尺以下。開放式看最遠一區，先關閉一齊開放閥二次側之止水閥，再由手動或自動啟動裝置使加壓送水裝置啟動，判定重點是一齊開放閥動作是否正常，本身不量放水壓力。補助撒水栓則用任一支確認操作性能，並量放水壓力與放水量，另確認皮管之延長及收納是否容易。\n三者共同的注意事項是：於檢查類似醫院之場所，因切換成緊急電源可能會造成困擾時，得使用常用電源檢查。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-water-chemical-011","室內消防栓進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",11,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-113-1-water-chemical-013","水道連結型自動撒水設備進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",13,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-113-1-water-chemical-010","有關室內消防栓測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",10,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-113-1-water-chemical-014","依據消防安全設備及必要檢修項目檢修基準，於檢查類似醫院之場所時，因切換成緊急電源可能會造成困擾時，得使用常用電源檢查，下列消防安全設備何者不適用此一規定？",14,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-113-1-water-chemical-009","高度危險工作場所設置室外消防栓進行檢修之綜合檢查，依據消防安全設備及必要檢修項目檢修基準規定，下列敘述何者錯誤？",9,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-113-1-water-chemical-015","有關滅火藥劑每公斤核算空氣量或氮氣量，依據惰性氣體與鹵化烴滅火設備之綜合檢查，下列何者與消防安全設備及必要檢修項目檢修基準規定不同？",15,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-112-1-water-chemical-012",112,"依據滅火器認可基準規定，由滅火器所充填之滅火藥劑量判別，下列何者屬大型滅火器？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-water-chemical-012",111,"有關水霧滅火設備，依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-water-chemical-012",110,"進行乾粉滅火設備性能檢查時，對於滅火藥劑檢查注意事項，溫度及濕度超過多少以上時，應暫停檢查？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-water-chemical-012",109,"消防水系統設置呼水裝置時，其溢水用排水管口徑應在多少尺寸以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-012",108,"主成分為碳酸氫鉀及尿素化合物之乾粉滅火藥劑，採全區放射方式時，每立方公尺防護區域所需滅火藥劑量為多少公斤？",1785129971597]