[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-113-1-fire-law-030":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-消防法規概要-030","fire-113-1-fire-law-030",113,1,30,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準規定，對於電動機之構造與機能，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"電動機應能確實動作，對機械強度、電氣性能應具充分耐久性，且操作維修、更換零件、修理須簡便","電動機各部分之零件應確實固定，不得有任意鬆動之現象","幫浦在額定負荷狀態下，應能順利啟動","電動機在額定輸出連續運轉 8 小時後，不得發生異狀，且在超過額定輸出之 10%輸出力運轉 0.5 小時，仍不致發生障礙，引起過熱現象","D",null,[],false,"本題考點：《消防幫浦加壓送水裝置等及配管摩擦損失計算基準》第 9 點電動機之構造與第 10 點電動機之機能。\n【正解理由】依該基準第 10 點第二款，電動機在額定輸出連續運轉八小時後，不得發生異狀，且在超過額定輸出之百分之十輸出力運轉一小時，仍不致發生障礙、引起過熱現象。(D) 前段的八小時與百分之十均與條文相同，唯超載運轉時間被寫成 0.5 小時，與所定之一小時不符，故選 D。\n【逐項排除】\n(A) 為第 9 點第一款：電動機應能確實動作，對機械強度、電氣性能應具充分耐久性，且操作維修、更換零件、修理須簡便，敘述正確。\n(B) 為第 9 點第二款：電動機各部分之零件應確實固定，不得有任意鬆動之現象，敘述正確。\n(C) 為第 10 點第一款：幫浦在額定負荷狀態下，應能順利啟動，屬機能規定，敘述正確。\n(D) 超過額定輸出之百分之十輸出力，應能運轉一小時而不發生障礙、過熱，本項寫成 0.5 小時，時間短於規定，即為所求。\n【記憶點】電動機記「額定連轉八小時，加一成再撐一小時」；構造在第 9 點、機能在第 10 點，兩點分工不要對調。","本基準的位階來自《各類場所消防安全設備設置標準》第 234 條：依該標準設置之室內消防栓、室外消防栓、自動撒水、水霧滅火、泡沫滅火、冷卻撒水、射水設備及連結送水管等設備，其消防幫浦、電動機、附屬裝置及配管摩擦損失計算，由中央消防機關另定之。因此它的體例是「點」而非「條」，引用時寫第幾點。\n同一份基準的常考數值可以一起背。第 5 點幫浦性能：額定出水量在性能曲線上之全揚程須達額定揚程之百分之一百至百分之一百十；出水量達額定出水量百分之一百五十時，全揚程應達性能曲線上全揚程之百分之六十五以上；全閉揚程應為性能曲線上全揚程之百分之一百四十以下。動力方面，額定出水量時軸動力不得超過馬達之額定輸出馬力，額定出水量百分之一百五十時不得超過馬達額定輸出馬力之百分之一百十。第 22 點另定加壓送水裝置所用壓力表及連成表，應使用精度在 1.5 級以上品質者，或具有同等以上強度及性能者。\n第 13 點則把電動機啟動方式按輸出功率分兩列：十一瓩未滿者，得採直接啟動、星角啟動、閉路式星角啟動、電抗器啟動、補償器啟動、二次電阻啟動或其他特殊啟動方式；十一瓩以上者，列有星角啟動、閉路式星角啟動、電抗器啟動、補償器啟動、二次電阻啟動及其他特殊啟動方式。同點並定直流電動機之啟動方式應具有與前款同等以上、能降低啟動電流者，電源切換為緊急電源時啟動裝置應具有不必再操作即能繼續運轉之構造。\n易混淆提醒：第 9 點管的是硬體本身（固定、耐久、維修簡便），第 10 點管的是運轉表現（能否順利啟動、能否承受連續與超載運轉），命題者最常把兩點的內容互換，或只改動其中一個時間、一個百分比。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-fire-law-029","有關消防安全設備檢修申報之相關規定，下列敘述何者正確？",29,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-113-1-fire-law-031","依建築技術規則建築設計施工編規定，所謂「無窗戶居室」係指有效採光面積未達該居室樓地板面積多少者？",31,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-113-1-fire-law-028","直轄市、縣（市）有登記執業之消防設備師或消防設備士達多少人以上者，得組織消防設備師公會或消防設備士公會？",28,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-113-1-fire-law-032","依建築技術規則建築設計施工編規定，有關耐燃合板、耐燃纖維板、耐燃塑膠板及石膏板等耐燃材料，係指耐燃幾級之材料？",32,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-113-1-fire-law-027","依消防設備人員法規定，下列敘述何者錯誤？",27,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-113-1-fire-law-033","依建築技術規則建築設計施工編規定，下列何者不視為居室？",33,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-030",114,"下列何者非屬各類場所消防安全設備設置標準之警報設備？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-law-030",112,"依消防安全設備及必要檢修項目檢修基準之規定，有關惰性氣體滅火設備之綜合檢查，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-030",111,"依各類場所消防安全設備設置標準規定，某樓層高度超過 10 公尺且樓地板面積在 700 平方公尺以上之高架儲存倉庫，其撒水頭設置應符合之規定，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-030",110,"可燃性高壓氣體儲存場所防爆牆分為鋼筋混凝土製、混凝土空心磚製及鋼板製等三種，並應設置於堅固基礎上，強度應能承受可能預料之氣體爆炸衝擊，有關混凝土空心磚製防爆牆之規定，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-030",109,"依各類場所消防安全設備檢修及申報作業基準，有關避難器具外觀檢查之規定，緩降機下降空間之判定，在無其他突出物干擾的情境下，以器具中心半徑多少公分的圓柱形範圍內，為緩降機的下降空間？",1785129968976]