[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-113-1-fire-law-024":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-消防法規概要-024","fire-113-1-fire-law-024",113,1,24,"有關避難器具支固器具及固定部之結構、強度計算及施工方法之規定，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"裝置緩降機之固定部之承載荷重為最大使用人數乘以 390(kgf)","裝置直降式救助袋之承載荷重為「有效長度除以 2 m 所得值（小數點以下無條件進位）× 195」(kgf)","斜降式救助袋之下部支撐裝置固定在降落面等之器具，其固定部展開救助袋時，與降落面角度約為 35 度","設置避難器具用升降口以錨定方式安裝在建築物本體之構造者，其固定處所應有 4 處以上","B",null,[],false,"本題考點：《避難器具支固器具及固定部之結構、強度計算及施工方法》所定各類避難器具之承載荷重（壹、設計載重之表一）、固定部角度與固定處所數量。\n【正解理由】依該基準壹、設計載重，裝置避難器具之固定部應能承受表一承載荷重與附加荷重之和。表一就直降式救助袋按袋長 L 分四級距給固定值：10 公尺以下 660 kgf、超過 10 至 20 公尺 900 kgf、超過 20 至 30 公尺 1035 kgf、超過 30 公尺 1065 kgf，不作換算。而「有效長度除以 2 公尺所得值（小數點以下無條件進位）乘以 195」是同一張表一就避難梯所定之算式。本項把避難梯的算式套到直降式救助袋，張冠李戴，故選 B。\n【逐項排除】\n(A) 正確。表一就緩降機定承載荷重為最大使用人數乘以 390 kgf。\n(B) 錯誤，為所求。直降式救助袋依表一按袋長取上列四個級距固定值，非以有效長度除以 2 公尺再乘以 195 計算。\n(C) 正確。該基準柒、斜降式救助袋下部支撐裝置固定器具一段明定，固定部展開救助袋時與降落面角度約為 35 度。\n(D) 正確。該基準伍、設置避難器具用升降口之施工方法一段明定，以錨定方式安裝在建築物本體之構造者，其固定處所應有 4 處以上。\n【記憶點】「除以 2 公尺進位再乘 195」只屬避難梯；緩降機看人數乘 390，直降式救助袋看袋長查 660、900、1035、1065。","本基準以「壹、貳、參……」分段編排，並非以條次編排，引用時應寫段名或表名。壹、設計載重規定，固定部（指裝設避難器具之樑、柱、樓板等堅固構造或經補強之部分）應能承受表一承載荷重（Ａ欄）與附加荷重（Ｂ欄）之和，荷重方向依Ｃ欄。表一除本題涉及者外，另定滑杆與避難繩索均為 390 kgf；斜降式救助袋按袋長分上端、下端兩欄，15 公尺以下為上端 375、下端 285 kgf，超過 15 至 30 公尺為 585 與 525 kgf，超過 30 至 40 公尺為 735 與 645 kgf，超過 40 公尺為 870 與 750 kgf，荷重方向為上端部分俯角 70 度、下端部分仰角 25 度；滑台為上端平台面積每平方公尺 330 加滑降面長度每公尺 130，避難橋為每平方公尺 330。同為救助袋，直降式給單一數值、斜降式分上下端，兩者不可互推。\n柒段就斜降式救助袋下部支撐裝置之固定器具另定表八，按袋長 15 公尺以下、超過 15 至 30 公尺、超過 30 至 40 公尺、超過 40 公尺，分別為 285、525、645、750 公斤重，荷重方向皆為仰角 25 度。陸段就固定部材料使用錨定螺栓時，給出鎖緊扭力公式Ｔ＝0.24ＤＮ，Ｔ 為鎖緊扭力、Ｄ 為螺栓直徑、Ｎ 為試驗荷重即設計拉拔荷重。\n與本基準搭配的設置規定在《各類場所消防安全設備設置標準》：第 167 條就緩降機、第 170 條就救助袋，均要求支固器具設在柱、地板、樑或其他構造上較堅固之部分，並以螺栓、熔接或其他堅固方法裝置；第 173 條要求支固器具及固定架使用符合 CNS 二四七三、四四三五規定或同等以上強度及耐久性之材料，並施予耐腐蝕加工處理。驗收判定則在《消防安全設備測試報告書測試方法及判定要領》避難器具章，其荷重試驗規定救助袋施加 300 公斤以上、緩降機（多人數用以外者）195 公斤以上。\n兩個角度務必分清：本題所稱 35 度，是固定器具埋設場所、固定部展開救助袋時與降落面之角度；測試要領外觀試驗所稱斜降式救助袋伸展時對水平樓地板面約 45 度，指的是袋體伸展狀態，對象不同。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-fire-law-023","依據消防設備人員法規定，下列敘述何者錯誤？",23,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-113-1-fire-law-025","依消防設備人員法規定，消防設備人員執業執照有效期間為幾年？",25,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-113-1-fire-law-022","依消防設備人員法規定，有關消防設備人員公會之規定，下列何者正確？",22,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-113-1-fire-law-026","依消防安全設備檢修專業機構管理辦法規定，檢修機構自行停業、受停業處分或逾多久不辦理檢修業務時，應報中央主管機關備查，並將原領證書送中央主管機關註記後發還之？",26,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-113-1-fire-law-021","有關消防設備人員執行業務，下列敘述何者錯誤？",21,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-113-1-fire-law-027","依消防設備人員法規定，下列敘述何者錯誤？",27,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-024",114,"依避難器具支固器具及固定部之結構、強度計算及施工方法規定，有關斜降式救助袋之下部支撐裝置固定在降落面等器具之構造、強度及埋設到降落面之方法，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-112-1-fire-law-024",112,"某一消防設備士受託辦理一家辦公大樓消防安全設備檢修，該大樓依規定設置之全部緩降機經消防設備士執行下降檢查，測量每具緩降機之下降距離及下降時間，經計算出之平均下降速度全部符合規定，其緩降機之下降距離及下降時間，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-024",111,"某室外儲槽場所儲槽儲存第四類公共危險物品，儲槽容量合計為 25 萬公秉，防液堤高度應在多少公尺以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-024",110,"依各類場所消防安全設備設置標準規定，有關連結送水管之送水設計壓力規定計算，下列敘述何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-024",109,"依各類場所消防安全設備設置標準之規定，有一容納超過 300 人老人福利機構餐廳，其樓地板面積在多少平方公尺以上，廚房排油煙管及煙罩即應裝設簡易自動滅火裝置？",1785129968931]