[{"data":1,"prerenderedAt":74},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-040":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":53,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-警報與避難系統消防安全設備概要-040","fire-113-1-alarm-evacuation-040",113,1,40,"依據火警探測器認可基準，對於差動式探測器直線上升的動作試驗，自室溫狀態下以平均每分鐘 T℃直線升溫速度之水平氣流吹向時，應在 M 分鐘以內動作，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"差動式一種：T=2，M=15","差動式二種：T=3，M=15","差動式一種：T=10，M=4.5","差動式二種：T=20，M=30","C",null,[],false,"本題考點：《火警探測器認可基準》所定差動式局限型探測器靈敏度試驗中，「直線上升」動作試驗的升溫速度 T 與動作時限 M。\n【正解理由】依《火警探測器認可基準》壹、技術規範及試驗方法 六、靈敏度試驗（一）差動式局限型探測器，動作試驗分階段上升與直線上升兩式；直線上升明定「自室溫狀態下以平均每分鐘 T℃直線升溫速度之水平氣流吹向時，應在 M 分鐘以內動作」。表 1 所列 T 值一種為 10、二種為 15，M 值一、二種同為 4.5。故差動式一種係每分鐘 10℃、應在 4.5 分鐘以內動作，故選 C。\n【逐項排除】\n(A) 一種的 2 與 15 是表 1 的 t 與 m，屬不動作試驗——以平均每分鐘 2℃直線升溫速度吹向時，應在 15 分鐘以內不動作。\n(B) 二種的 3 與 15 同樣是表 1 的 t 與 m，即不動作試驗值；二種的動作試驗為每分鐘 15℃、4.5 分鐘以內。\n(C) 表 1 一種之 T＝10、M＝4.5，種別與數值均相符。\n(D) 二種之 T 為 15 而非 20，M 為 4.5 而非 30；表 1 沒有每分鐘 20℃這一格，30 是一、二種共通之 N 值（階段上升動作試驗的秒數），單位為秒。\n【記憶點】差動式局限型直線上升動作試驗：一種每分鐘 10℃、二種每分鐘 15℃，時限同為 4.5 分鐘；每分鐘 2℃或 3℃ 配 15 分鐘那一組是「不動作」試驗。","表 1 差動式局限型探測器靈敏度試驗數值表把十個符號分兩組：動作試驗的 K、V、N、T、M 與不動作試驗的 k、v、n、t、m。一種為 K＝20℃、V＝70 cm\u002Fsec、N＝30 秒、T＝每分鐘 10℃、M＝4.5 分，k＝10℃、v＝50 cm\u002Fsec、n＝1 分、t＝每分鐘 2℃、m＝15 分；二種為 K＝30℃、V＝85 cm\u002Fsec、N＝30 秒、T＝每分鐘 15℃、M＝4.5 分，k＝15℃、v＝60 cm\u002Fsec、n＝1 分、t＝每分鐘 3℃、m＝15 分。N、M、n、m 四值一、二種相同，隨種別變動的是 K、V、T 與 k、v、t。\n差動式分布型走另一張表，表 2 列 t1 與 t2：一種 7.5℃與 1℃、二種 15℃與 2℃、三種 30℃與 4℃；動作試驗為離檢出部最遠處之空氣管 20 公尺部分以每分鐘 t1℃直線昇溫，應在 1 分鐘內動作，不動作試驗為空氣管全部在每分鐘 t2℃直線昇溫時 7 分 30 秒內不得動作。\n最容易與本題互套的是《消防安全設備測試報告書測試方法及判定要領》火警自動警報設備性能試驗——竣工現場以加熱或加煙試驗器測至動作為止之時間，單位是秒：差動式局限型與補償式局限型第一、二種均為 30 秒；定溫式局限型特種 40 秒、第一種 60 秒、第二種 120 秒，熱類比式局限型特種 40 秒；但這兩型之標稱動作溫度或有關火災標示之設定標示溫度和周圍溫度的差超過 50 度時，得將動作時間設定為 2 倍。偵煙式一組（離子式局限型、光電式局限型、離子化類比式局限型、光電類比式局限型）特種 30 秒、第一種 60 秒、第二種 90 秒，但如為蓄積型探測器，動作時間應在表列時間加上標稱蓄積時間及 5 秒後之時間以內；光電式分離型與光電類比式分離型，非蓄積型應在 30 秒以內，蓄積型為 30 秒加上標稱蓄積時間及 5 秒後之時間以內。「及 5 秒」是條文明文，漏抄會把時限算短。\n非再用型定溫式局限型一經動作不能復用，改依抽取個數表：設置 1 至 10 個抽 1、11 至 50 個抽 2、51 至 100 個抽 4、101 個以上抽 7 個。",true,[28,32,37,41,45,49],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-alarm-evacuation-039","某捷運高架車站，因地形環境因素致車站早晚霧氣瀰漫，為防止霧氣結露產生探測器誤動作，選設之探測器除考量防水性能外，試問下列何者探測器不適用？",39,{"webId":33,"stem":34,"number":35,"year":36,"session":12},"fire-114-1-alarm-evacuation-004","某電影院放映場所火警自動警報設備所使用之蓄積型偵煙探測器有 10 秒之蓄積時間，其所使用之中繼器有 10 秒之蓄積時間，則其受信總機之蓄積時間，最多可為多少秒？",4,114,{"webId":38,"stem":39,"number":40,"year":11,"session":12},"fire-113-1-alarm-evacuation-038","針對差動式分布型空氣管式探測器進行接點水高試驗，其試驗之目的為何？",38,{"webId":42,"stem":43,"number":12,"year":44,"session":12},"fire-106-1-alarm-evacuation-001","某一 KTV 視聽歌唱場所設於大樓地下層，依規定樓地板面積如合計超過多少，應設置瓦斯漏氣火警自動警報設備？",106,{"webId":46,"stem":47,"number":48,"year":11,"session":12},"fire-113-1-alarm-evacuation-037","有關第三種偵煙局限型探測器之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不符？",37,{"webId":50,"stem":51,"number":52,"year":44,"session":12},"fire-106-1-alarm-evacuation-002","對於消防安全設備緊急供電系統之配線之規定，下列何者正確？",2,[54,58,62,66,70],{"webId":55,"year":56,"stem":57,"number":13},"fire-112-1-alarm-evacuation-040",112,"依各類場所消防安全設備設置標準，醫院熱水室之場所適用選擇設置下列何種探測器？",{"webId":59,"year":60,"stem":61,"number":13},"fire-111-1-alarm-evacuation-040",111,"光電式分離型探測器進行外觀試驗，以目視確認探測器光軸應平行牆壁距離 X 公分以上，且探測器之光軸高度應在天花板等高度 Y%以上之位置。而使用減光罩進行動作試驗，非蓄積型探測器之動作時間應在 Z 秒內。則 X、Y、Z 值，下列何者正確？",{"webId":63,"year":64,"stem":65,"number":13},"fire-110-1-alarm-evacuation-040",110,"避難器具之裝設規定，下列何者正確？",{"webId":67,"year":68,"stem":69,"number":13},"fire-109-1-alarm-evacuation-040",109,"有關火警自動警報設備受信總機周圍狀況外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":71,"year":72,"stem":73,"number":13},"fire-108-1-alarm-evacuation-040",108,"依各類場所消防安全設備設置標準規定，緊急供電系統之配線的保護下列何者錯誤？",1785129962899]