[{"data":1,"prerenderedAt":74},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-039":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":53,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-警報與避難系統消防安全設備概要-039","fire-113-1-alarm-evacuation-039",113,1,39,"某捷運高架車站，因地形環境因素致車站早晚霧氣瀰漫，為防止霧氣結露產生探測器誤動作，選設之探測器除考量防水性能外，試問下列何者探測器不適用？",{"A":16,"B":17,"C":18,"D":19},"差動式局限型一種","補償式局限型一種","定溫式局限型一種","差動式分布型一種","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 117 條就「會結露之場所」所定之探測器選設規定。\n【正解理由】題示捷運高架車站早晚霧氣瀰漫、有結露之虞，即第 117 條第一項第七款所稱「會結露之場所」。該項規定偵煙式或熱煙複合式局限型探測器不得設於該處所，故四個選項才全部落在感熱式；同條第三項並規定，前二項所列場所應依所定之表狀況，選擇適當探測器設置。在該表「會結露之場所」一欄，列為適用者為差動式分布型、補償式局限型與定溫式，差動式局限型並未列為適用之探測器，故選 A。\n【逐項排除】\n(A) 差動式局限型一種在第 117 條第三項所定之選設表中，未列於會結露之場所之適用探測器，題示情形不得選用。\n(B) 補償式局限型一種在該表會結露之場所一欄列為適用之探測器，可以選用。\n(C) 定溫式局限型一種在該表會結露之場所一欄列為適用之探測器，可以選用。\n(D) 差動式分布型一種在該表會結露之場所一欄列為適用之探測器，可以選用。\n【記憶點】結露場所先把偵煙式與熱煙複合式局限型排除，再從選設表挑差動式分布型、補償式局限型與定溫式；差動式「局限型」不在其中。","第 117 條是本科最典型的「不得設置＋依表選設」雙層條文，讀法要分三層。第一項列偵煙式或熱煙複合式局限型探測器不得設置之九種處所：塵埃、粉末或水蒸氣會大量滯留之場所；會散發腐蝕性氣體之場所；廚房及其他平時煙會滯留之場所；顯著高溫之場所；排放廢氣會大量滯留之場所；煙會大量流入之場所；會結露之場所；設有用火設備其火焰外露之場所；其他對探測器機能會造成障礙之場所。第二項列火焰式探測器不得設置之處所，其第一款照抄範圍為「前項第二款至第四款或第六款至第八款所列之處所」，第二款為水蒸氣會大量滯留之處所，第三款為其他對探測器機能會造成障礙之處所。第三項則規定前二項所列場所，依表狀況選擇適當探測器設置，該表以場所為欄、以探測器種類為列，逐格標記是否適用。\n《消防安全設備及必要檢修項目檢修基準》火警自動警報設備之外觀檢查，在探測器一節的注意事項也接上這條：不能設置偵煙式探測器或熱煙複合式局限型探測器之場所，應依表 13-1 選設；有發生誤報或延遲感知之虞處，應依表 13-2 選設。外觀檢查的判定方法並列有「適應性」一項，要求應設置適合設置場所之探測器，本題所問的正是這個判定點。\n本題另一個伏筆是題幹自己寫的「除考量防水性能外」。防水性能與「哪一種探測器可以用」是兩件並行的要求，先過選設表這一關，再談防水型的採用。\n延伸考點上，感熱式探測器的規定散在數條：第 119 條定探測區域，裝置面四周淨高四十公分以上之樑或類似構造體區劃包圍，差動式分布型及偵煙式探測器則為六十公分以上；第 120 條定差動式局限型、補償式局限型及定溫式局限型之下端裝設位置與有效探測範圍表；第 121 條定差動式分布型空氣管式、熱電偶式、熱半導體式三種型式的設置規定。裝置場所高度與探測器種類的對照則在第 114 條，同樣是選設題的常客。",true,[28,32,36,40,45,49],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-alarm-evacuation-038","針對差動式分布型空氣管式探測器進行接點水高試驗，其試驗之目的為何？",38,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-113-1-alarm-evacuation-040","依據火警探測器認可基準，對於差動式探測器直線上升的動作試驗，自室溫狀態下以平均每分鐘 T℃直線升溫速度之水平氣流吹向時，應在 M 分鐘以內動作，下列敘述何者正確？",40,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-113-1-alarm-evacuation-037","有關第三種偵煙局限型探測器之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不符？",37,{"webId":41,"stem":42,"number":43,"year":44,"session":12},"fire-114-1-alarm-evacuation-004","某電影院放映場所火警自動警報設備所使用之蓄積型偵煙探測器有 10 秒之蓄積時間，其所使用之中繼器有 10 秒之蓄積時間，則其受信總機之蓄積時間，最多可為多少秒？",4,114,{"webId":46,"stem":47,"number":48,"year":11,"session":12},"fire-113-1-alarm-evacuation-036","依住宅用火災警報器設置辦法規定，住宅用火災警報器應安裝於寢室、廚房、樓梯。若非屬前三類處所且任一樓層有超過 X 平方公尺之居室達 Y 間以上者，則設於走廊。則 X、Y 分別為何？",36,{"webId":50,"stem":51,"number":12,"year":52,"session":12},"fire-106-1-alarm-evacuation-001","某一 KTV 視聽歌唱場所設於大樓地下層，依規定樓地板面積如合計超過多少，應設置瓦斯漏氣火警自動警報設備？",106,[54,58,62,66,70],{"webId":55,"year":56,"stem":57,"number":13},"fire-112-1-alarm-evacuation-039",112,"依消防安全設備及必要檢修項目檢修基準，檢查一一九火災通報裝置性能時，有關通報裝置本體檢查，下列敘述何者錯誤？",{"webId":59,"year":60,"stem":61,"number":13},"fire-111-1-alarm-evacuation-039",111,"民國 84 年取得使用執照之大樓，測試其火警地區音響裝置之音壓何者正確？",{"webId":63,"year":64,"stem":65,"number":13},"fire-110-1-alarm-evacuation-039",110,"依消防安全設備及必要檢修項目檢修基準，火焰式探測器進行性能檢查時，使用火焰探測器用動作試驗器，探測器應在多少時間內動作？",{"webId":67,"year":68,"stem":69,"number":13},"fire-109-1-alarm-evacuation-039",109,"有關緊急照明設備之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":71,"year":72,"stem":73,"number":13},"fire-108-1-alarm-evacuation-039",108,"依各類場所消防安全設備設置標準規定，下列何種場所不須設置緊急電源插座？",1785129962885]