[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-037":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-警報與避難系統消防安全設備概要-037","fire-113-1-alarm-evacuation-037",113,1,37,"有關第三種偵煙局限型探測器之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不符？",{"A":16,"B":17,"C":18,"D":19},"應設置在距離牆壁或樑 60 公分以上之位置","設於走廊及通道時，水平距離應在 20 公尺以下","設於樓梯或坡道時，垂直距離每 10 公尺應設置 1 個以上","天花板高度未滿 2.3 公尺之居室或未滿 40 平方公尺之居室，應設置在入口附近","B",null,[],false,"本題考點：偵煙式局限型探測器在《消防安全設備測試報告書測試方法及判定要領》外觀試驗的判定項目，關鍵在走廊、通道量的是「步行距離」而非「水平距離」。\n【正解理由】依《消防安全設備測試報告書測試方法及判定要領》火警自動警報設備之外觀試驗，偵煙式探測器（光電式分離型及類比式除外）「設於走廊及通道時，步行距離應在 30m（如為第三種探測器，則為 20m）以下」；《各類場所消防安全設備設置標準》第 122 條第五款亦明定「探測器在走廊及通道，步行距離每三十公尺至少設置一個；使用第三種探測器時，每二十公尺至少設置一個」。20 公尺這個數值本身無誤，錯的是把「步行距離」寫成「水平距離」，故選 B。\n【逐項排除】\n(A) 判定要領明定「應設置在距離牆壁或樑 0.6m 以上之位置」，第 122 條第三款同為六十公分以上，敘述相符。\n(B) 第三種探測器在走廊及通道所限制者為步行距離 20 公尺，並非水平距離，與規定不符。\n(C) 判定要領明定「設於樓梯或坡道時，垂直距離每 15m（如為第三種探測器，則為 10m）應設置 1 個以上」，敘述相符。\n(D) 判定要領明定「如為天花板高度未滿 2.3m 之居室或未滿 40 平方公尺之居室，應設置在入口附近」，第 122 條第一款同旨，敘述相符。\n【記憶點】走廊通道量「步行距離」、樓梯坡道量「垂直距離」，第三種探測器對應的是 20 公尺與 10 公尺。","偵煙式探測器的裝置距離，在《各類場所消防安全設備設置標準》第 122 條與《消防安全設備測試報告書測試方法及判定要領》火警自動警報設備外觀試驗兩處各寫一次，文字幾乎一致，命題者常在兩份文件之間交叉出題。第 122 條共七款：第一款，居室天花板距樓地板面高度在二點三公尺以下或樓地板面積在四十平方公尺以下時，應設在其出入口附近；第二款，探測器下端裝設在裝置面下方六十公分範圍內；第三款，裝設於距離牆壁或樑六十公分以上之位置；第四款，依探測器種類及裝置面高度查有效探測範圍，未滿四公尺者，一種或二種為 150 平方公尺、三種為 50 平方公尺，四公尺以上未滿二十公尺者，一種或二種為 75 平方公尺，三種於該欄未列數值；第五款，走廊及通道步行距離每三十公尺至少設置一個、第三種每二十公尺至少設置一個，且距盡頭之牆壁在十五公尺以下、第三種在十公尺以下；第六款，樓梯、斜坡通道及電扶梯垂直距離每十五公尺至少設置一個、第三種每十公尺至少設置一個；第七款，昇降機坑道及管道間（管道截面積在一平方公尺以上者）應設在最頂部。\n判定要領在同一段把免設情形列得更細：未和樓梯相接之 10m 以下的走廊或通道、至樓梯之步行距離在 10m 以下的走廊或通道、開放式的走廊或通道得免設；樓梯或坡道則於開放式的樓梯上得免設。這幾項可與第 122 條第五款但書（走廊或通道至樓梯之步行距離在十公尺以下，且樓梯設有平時開放式防火門或居室有面向該處之出入口時，得免設）對照著記。\n易混淆之處在於光電式分離型不適用第 122 條，而依同標準第 123 條設置，該條第七款用的正是「探測器之光軸與警戒區任一點之水平距離，在七公尺以下」。本題把「水平距離」放進走廊、通道的敘述，等於把分離型的量法套到局限型身上，是本科高頻的偷換用語手法。\n另一組並列數值也常被抽考：一種或二種在走廊通道為三十公尺、樓梯坡道為十五公尺、距盡頭牆壁十五公尺；第三種對應為二十公尺、十公尺、十公尺。再往外延伸，第 119 條的探測區域規定是裝置面四周淨高四十公分以上之樑或類似構造體區劃包圍，但差動式分布型及偵煙式探測器須為六十公分以上，也常與本條合併命題。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-alarm-evacuation-036","依住宅用火災警報器設置辦法規定，住宅用火災警報器應安裝於寢室、廚房、樓梯。若非屬前三類處所且任一樓層有超過 X 平方公尺之居室達 Y 間以上者，則設於走廊。則 X、Y 分別為何？",36,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-113-1-alarm-evacuation-038","針對差動式分布型空氣管式探測器進行接點水高試驗，其試驗之目的為何？",38,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-113-1-alarm-evacuation-035","某揚聲器額定輸出功率 10 W，量測其額定功率之音響功率位準為 98 dB，試問依緊急廣播設備用揚聲器認可基準規定，採性能設計之緊急廣播設備揚聲器，於該揚聲器上所標示之音響功率位準（1 W）應為多少 dB？",35,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-113-1-alarm-evacuation-039","某捷運高架車站，因地形環境因素致車站早晚霧氣瀰漫，為防止霧氣結露產生探測器誤動作，選設之探測器除考量防水性能外，試問下列何者探測器不適用？",39,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-113-1-alarm-evacuation-034","依據消防安全設備及必要檢修項目檢修基準，針對 119 火災通報裝置本體實施性能檢查，其中以火警自動警報設備連動啟動將一區段蓄積語音送出後，再操作手動啟動裝置，應能再送出蓄積語音，此為下列何種檢查項目？",34,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-113-1-alarm-evacuation-040","依據火警探測器認可基準，對於差動式探測器直線上升的動作試驗，自室溫狀態下以平均每分鐘 T℃直線升溫速度之水平氣流吹向時，應在 M 分鐘以內動作，下列敘述何者正確？",40,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-112-1-alarm-evacuation-037",112,"下列何者非各類場所消防安全設備設置標準規定應設置無線電通信輔助設備之場所？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-037",111,"醫院之排煙設備進行綜合檢查時，緊急電源之檢查應如何落實？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-037",110,"下列有關緊急電源插座之設置，何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-037",109,"有關警報系統消防安全設備設置，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-037",108,"某機場候機室樓地板面積 300 m2，自然排煙設備其窗戶都在天花板或其下方 80 公分範圍內，共有 10 扇窗，採正向由上往外推可達 90°，請問每一扇窗面積多大才合格？",1785129962868]