[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-028":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-警報與避難系統消防安全設備概要-028","fire-113-1-alarm-evacuation-028",113,1,28,"依消防安全設備及必要檢修項目檢修基準，針對防災監控系統綜合操作裝置進行性能檢查，有關消防搶救支援性能項目，於 LCD 螢幕應能針對下列各樓層平面圖，以簡明易操作之方式切換其表示。所敘述之樓層平面圖下列何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"火警探測器、火警發信機或瓦斯漏氣檢知器動作樓層（起火樓層）之平面圖","起火樓以外之火警探測器、火警發信機或瓦斯漏氣檢知器動作樓層之平面圖","起火樓直上層及直上二層之平面圖","起火樓直下層之平面圖及地面層之平面圖","D",null,[],false,"本題考點：《消防安全設備及必要檢修項目檢修基準》第二十四之一章防災監控系統綜合操作裝置性能檢查中，「消防搶救支援性能」所列應能切換表示之樓層平面圖。\n【正解理由】該章二、性能檢查（二）綜合操作裝置（本體）之判定方法第（12）項Ｂ目逐項列出：（Ａ）火警探測器、火警發信機或瓦斯漏氣檢知器動作樓層（起火樓層）之平面圖；（Ｂ）起火樓以外之火警探測器、火警發信機或瓦斯漏氣檢知器動作樓層之平面圖；（Ｃ）起火樓直上層及直上二層之平面圖；（Ｄ）起火樓直下層之平面圖；（Ｅ）地下層各層之平面圖，合計五項，其中並無「地面層之平面圖」。題目要選錯誤者，故選 D。\n【逐項排除】\n(A) 與該目（Ａ）逐字相符，敘述正確。\n(B) 與該目（Ｂ）逐字相符，敘述正確。\n(C) 與該目（Ｃ）逐字相符，直上層與直上二層均列入。\n(D) 錯誤所在。前半「起火樓直下層之平面圖」固與（Ｄ）相符，後半原文為「地下層各層之平面圖」，選項寫成「地面層之平面圖」，範圍與樓層都被改掉。\n【記憶點】五張圖依序是起火樓、其他動作樓、直上層與直上二層、直下層、地下層各層；最後一張是地下層各層，不是地面層。","防災監控系統綜合操作裝置是較新的設備類別。《設置標準》第 11 條把消防搶救上之必要設備分六款，本裝置列為第六款；第 30-1 條規定應設場所四款：高層建築物、總樓地板面積在五萬平方公尺以上之建築物、總樓地板面積在一千平方公尺以上之地下建築物、其他經中央主管機關公告之供公眾使用之場所。第 192-1 條第一項則規定應設置於防災中心、中央管理室或值日室等經常有人之處所，並監控或操作九款設備，依序為火警自動警報設備之受信總機、瓦斯漏氣火警自動警報設備之受信總機、緊急廣播設備之擴大機及操作裝置、連結送水管之加壓送水裝置及與其送水口處之通話連絡、緊急發電機、常開式防火門之偵煙型探測器、室內消防栓與自動撒水及泡沫及水霧等滅火設備加壓送水裝置、乾粉與惰性氣體及鹵化烴等滅火設備、排煙設備；同條第二項另定緊急電源準用第 38 條規定，且供電容量應供其有效動作二小時以上。\n\n檢修基準同章對「消防搶救支援性能」分兩段判定：Ａ 段要求 LCD 等所動作之所有樓層平面圖及與該樓層有關之事項應能簡明表示，包括發報之探測器與按下之火警發信機位置或警戒區域、偵測瓦斯漏氣檢知器之位置及瓦斯遮斷閥之動作狀況、構成防火區劃防火牆之表示及常開式防火門與防火鐵捲門與遮煙捲簾與防火閘門與排煙閘門與可動式防煙壁等的動作情況、排煙與進風機及排煙與進風口之作動情況、發電機與中繼幫浦啟動運轉及緊急昇降機召回功能；Ｂ 段才是本題所考的五種平面圖切換表示，並註明以分棟或防火區劃表示。\n\n易混淆之處在檢查層次：本題敘述屬「二、性能檢查」；同章「三、綜合檢查」的檢查方式則是切換至預備電源或緊急電源狀態下，操作各消防安全設備及防火避難設施，依表 2 及表 3 之相關警報項目及操作項目確認功能是否正常，其注意事項並提醒切換至蓄電池設備狀態實施時須考量蓄電池動作之容量時間。設置面的延伸考點是第 238 條防災中心，樓地板面積應在四十平方公尺以上，出入口至屋外任一出入口之步行距離在三十公尺以下。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-alarm-evacuation-027","有關出口標示燈、避難方向指示燈與緊急照明燈之緊急電源規定，下列敘述何者正確？",27,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-113-1-alarm-evacuation-029","有關特別安全梯與緊急昇降機間排煙室兼用時，其排煙設備採機械排煙、自然進風方式，則排煙機之排煙量應在 X m3\u002Fsec 以上；直接面向戶外之進風口開口面積應在 Y m2 以上則 X、Y 各為多少？",29,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-113-1-alarm-evacuation-026","依規定出口標示燈及避難方向指示燈，應保持不熄滅。惟為配合政府機關推動節能減碳措施，除上述燈具採用省電產品外，出口標示燈及走廊通道避難方向指示燈，符合下列何者規定，得予減光或消燈？",26,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-113-1-alarm-evacuation-030","某建築物於第五層開設健身休閒中心，依法應設置排煙設備。惟於該場所內之衣帽間規劃免設排煙設備，試問符合下列何種條件方得免設？",30,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-113-1-alarm-evacuation-025","依各類場所消防安全設備設置標準之規定，有關緊急電源插座之設置規定，下列敘述何者正確？",25,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-113-1-alarm-evacuation-031","避難器具於竣工查驗時，針對固定架或支固器具使用螺栓固定實施性能試驗，為確認螺栓對拉出之耐力，進行拉拔強度試驗。今使用直徑 10 毫米錨定螺栓，設計拉拔荷重（試驗荷重）為 960 公斤力（kgf），使用扭力扳手作為測定拉拔荷重之器具時，則鎖緊扭力應為多少公斤力-公分（kgf．cm）？",31,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-112-1-alarm-evacuation-028",112,"某一地下街其地下層設有瓦斯漏氣火警自動警報設備，其某一回路之檢知器數量有 40 個，依消防安全設備及必要檢修項目檢修基準使用「加瓦斯試驗器」進行加瓦斯測試，檢知器選取檢查數量為何？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-028",111,"非局限型探測器為有效偵知火災，下列何者為設置標準規定裝設於小空間內至少應有的長度或元件數量？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-028",110,"瓦斯漏氣火警自動警報設備進行性能檢查時，檢知區域警報裝置其音壓在距 1 公尺處應為多少分貝以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-028",109,"有關緊急廣播設備啟動裝置與緊急電話設置場所之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-028",108,"有關緊急廣播設備之敘述，下列何者錯誤？",1785129962776]