[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-警報與避難系統消防安全設備概要-025","fire-113-1-alarm-evacuation-025",113,1,25,"依各類場所消防安全設備設置標準之規定，有關緊急電源插座之設置規定，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"每一層任何一處至插座之步行距離在 50 公尺以下","插座電流供應容量為交流單相 110 伏特 15 安培，其容量約為 1.5 瓩以上","裝設高度距離樓地板 0.8 公尺以上 1.5 公尺以下","應從主配電盤設專用回路，各層至少設 1 回路以上之供電線路，且每回路之連接插座數在 10 個以下","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 191 條緊急電源插座之設置規定。\n【正解理由】第 191 條第二款明定「緊急電源插座之電流供應容量為交流單相一百一十伏特（或一百二十伏特）十五安培，其容量約為一點五瓩以上」，與本選項所述相符，故選 B。\n【逐項排除】\n(A) 第 191 條第一款所定為「每一層任何一處至插座之水平距離在五十公尺以下」，量的是水平距離而非步行距離，敘述錯誤。\n(B) 交流單相 110 伏特 15 安培、容量約 1.5 瓩以上，與第 191 條第二款相符，即為本題所求。\n(C) 第 191 條第四款規定緊急電源插座為接地型，裝設高度距離樓地板一公尺以上一點五公尺以下；選項所寫之 0.8 公尺以上與條文所定之一公尺以上不符。\n(D) 第 191 條第六款規定應從主配電盤設專用回路，各層至少設二回路以上之供電線路，且每一回路之連接插座數在十個以下；選項寫成各層至少設 1 回路，與二回路不符。\n【記憶點】緊急電源插座：水平距離五十公尺、110 伏特 15 安培約 1.5 瓩、裝設高度一至一點五公尺、每層專用回路二回路以上、每回路插座十個以下。","緊急電源插座是消防搶救上之必要設備，應設場所規定在第 29 條：十一層以上建築物之各樓層、總樓地板面積在一千平方公尺以上之地下建築物，以及依建築技術規則應設置之緊急昇降機間。設置細節則全在第 191 條，各款要一起記：第一款除水平距離五十公尺以下外，還規定應裝設於樓梯間或緊急昇降機間等（含各該處五公尺以內之場所）消防人員易於施行救火處；第四款除裝設高度一公尺以上一點五公尺以下外，還要求裝設二個於崁裝式保護箱內，保護箱長邊及短邊分別為二十五公分及二十公分以上、以厚度一點六毫米以上之鋼板或同等性能以上之不燃材料製、箱內有防止插頭脫落之 L 型或 C 型護鉤、箱蓋易於開閉、須接地、箱蓋標示緊急電源插座字樣每字在二平方公分以上，與室內消防栓箱等併設時須設於上方且箱蓋須能另外開啟；第五款規定在保護箱上方設紅色表示燈；第七款規定專用回路不得設漏電斷路器；第八款規定各插座設容量一百一十伏特、十五安培以上之無熔絲斷路器；第九款規定連接至緊急供電系統。\n驗收面可對照《消防安全設備測試報告書測試方法及判定要領》緊急電源插座之外觀試驗，其判定要領同樣寫每一層任何一處至插座之水平距離應在 50m 以下、每一回路之緊急電源插座數量應在 10 以下、各樓層至少應設二個回路以上之供電線路、專用幹線應可供給單相交流 110V 之 15A 以上的電力、保護箱應設置在距離樓地板面或樓梯面之高度 1m 以上 1.5m 以下的位置、以厚度 1.6mm 以上之鋼板製成，分歧回路並應設置 15A 之過電流遮斷器（如係配線用遮斷器則為 20A）。\n最後是易混淆對照，也是本題兩個誘答的來源：第 136 條緊急廣播設備之啟動裝置，規定各樓層任一點至啟動裝置之「步行距離」在五十公尺以下，並設在距樓地板高度零點八公尺以上一點五公尺以下範圍內。緊急電源插座量的是水平距離五十公尺、裝設高度一公尺以上一點五公尺以下，兩組數字放在一起背，就不會被選項互換騙過去。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-alarm-evacuation-024","依各類場所消防安全設備設置標準規定，有關引導燈具與緊急照明燈之照度規定，下列敘述何者錯誤？",24,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-113-1-alarm-evacuation-026","依規定出口標示燈及避難方向指示燈，應保持不熄滅。惟為配合政府機關推動節能減碳措施，除上述燈具採用省電產品外，出口標示燈及走廊通道避難方向指示燈，符合下列何者規定，得予減光或消燈？",26,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-113-1-alarm-evacuation-023","依各類場所消防安全設備設置標準規定，下列何場所或建築物未達應設置火警自動警報設備條件？",23,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-113-1-alarm-evacuation-027","有關出口標示燈、避難方向指示燈與緊急照明燈之緊急電源規定，下列敘述何者正確？",27,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-113-1-alarm-evacuation-022","某建築物設有火警受信總機 50 回路，竣工時實施性能試驗，於進行受信總機同時動作試驗時，使用常用電源，應將任意 X 回路設定在火警動作狀態；使用預備電源，應將任意 Y 回路設定在火警動作狀態，判定受信總機、主音響裝置、地區音響裝置、附屬裝置等性能應無異常。則 X+Y=？",22,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-113-1-alarm-evacuation-028","依消防安全設備及必要檢修項目檢修基準，針對防災監控系統綜合操作裝置進行性能檢查，有關消防搶救支援性能項目，於 LCD 螢幕應能針對下列各樓層平面圖，以簡明易操作之方式切換其表示。所敘述之樓層平面圖下列何者錯誤？",28,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-112-1-alarm-evacuation-025",112,"有關發電機設備設置場所之外觀試驗，依據緊急電源（發電機設備）測試報告書判定要領，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-025",111,"依 119 火災通報裝置認可基準規定，當常用電源停電，持續 X 分鐘待機狀態後，需保有 Y 分鐘以上可進行火災通報之電源容量；通話功能及回鈴應答試驗於 Z 秒內未收到回鈴信號，應可重複進行撥號。則 X、Y、Z 為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-025",110,"下列有關火警受信總機之裝置規定，何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-025",109,"有關火焰式探測器之設置，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-025",108,"依各類場所消防安全設備設置標準規定，火警自動警報設備之火警發信機（非定址式）與 P 型受信總機，其配線為何種配線？",1785129962748]