[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-113-1-alarm-evacuation-019":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-113-1-警報與避難系統消防安全設備概要-019","fire-113-1-alarm-evacuation-019",113,1,19,"某百貨公司設計有一挑高中庭，其高度為 14 公尺，依據各類場所消防安全設備設置標準之規定，請問下列探測器何者不適合？",{"A":16,"B":17,"C":18,"D":19},"光電式局限型二種","補償式局限型","差動式分布型","火焰式探測器","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 114 條「探測器應依裝置場所高度選擇種類」之對照表，十四公尺屬「八公尺以上未滿十五公尺」欄。\n【正解理由】第 114 條之表就裝置場所高度八公尺以上未滿十五公尺者，所列得選用之探測器為差動式分布型、離子式局限型一種或二種、光電式局限型一種或二種、光電式分離型、火焰式。補償式局限型並未列於該欄，挑高十四公尺之中庭即不得選用，故選 B。\n【逐項排除】\n(A) 光電式局限型二種列於八公尺以上未滿十五公尺欄，適合十四公尺之場所。\n(B) 補償式局限型僅列於未滿四公尺欄與四公尺以上未滿八公尺欄，八公尺以上之高度未列，故不適合，即為本題所求。\n(C) 差動式分布型列於八公尺以上未滿十五公尺欄，適合十四公尺之場所。\n(D) 火焰式列於八公尺以上未滿十五公尺欄，適合十四公尺之場所。\n【記憶點】八公尺以上未滿十五公尺只剩差動式分布型、離子式局限型一種或二種、光電式局限型一種或二種、光電式分離型與火焰式；補償式局限型與差動式局限型止於未滿八公尺。","《各類場所消防安全設備設置標準》第 114 條以裝置場所高度分四欄選擇探測器種類，本文並載明但書：同一室內之天花板或屋頂板高度不同時，以平均高度計，挑高中庭若上下有高低差就要先算平均高度再查表。四欄內容依序為：未滿四公尺欄列差動式局限型、差動式分布型、補償式局限型、定溫式、離子式局限型、光電式局限型、光電式分離型、火焰式；四公尺以上未滿八公尺欄列差動式局限型、差動式分布型、補償式局限型、定溫式特種或一種、離子式局限型一種或二種、光電式局限型一種或二種、光電式分離型、火焰式；八公尺以上未滿十五公尺欄列差動式分布型、離子式局限型一種或二種、光電式局限型一種或二種、光電式分離型、火焰式；十五公尺以上未滿二十公尺欄只剩離子式局限型一種、光電式局限型一種、光電式分離型一種、火焰式。整張表列到未滿二十公尺為止。\n與高度規定配套的還有幾條，一起記才不會漏。第 115 條規定探測器之裝置位置：天花板上設有出風口時，除火焰式、差動式分布型及光電式分離型探測器外，應距離該出風口一點五公尺以上；天花板設排氣口或回風口時，偵煙式探測器應裝置於排氣口或回風口周圍一公尺範圍內；局限型探測器以裝置在探測區域中心附近為原則，且不得傾斜四十五度以上，但火焰式不在此限。第 119 條規定探測區域係以淨高四十公分以上之樑或類似構造體區劃包圍，但差動式分布型及偵煙式探測器其裝置面四周淨高應為六十公分以上。\n第 122 條則是偵煙式探測器（光電式分離型除外）之有效探測範圍表：裝置面未滿四公尺時，一種或二種為 150 平方公尺、三種為 50 平方公尺；四公尺以上未滿二十公尺時，一種或二種為 75 平方公尺、三種則未列數值。第 124 條規定火焰式探測器應裝設於天花板、樓板或牆壁，距樓地板面一點二公尺範圍內之空間應在探測器標稱監視距離範圍內，不得設在有障礙物妨礙探測火災發生處，並應設在無日光照射之處，但設有遮光功能可避免探測障礙者不在此限。挑高中庭同時是高度題與種類題的常見舞台，這幾張表要一起背。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-113-1-alarm-evacuation-018","探測器容易因設置環境影響其探測能力，因此需考慮設置處所環境，根據各類場所消防安全設備設置標準之要求，補償式局限型二種探測器不適合安裝在下列場所？",18,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-113-1-alarm-evacuation-020","一棟建築物擁有地下 2 層以及地上 8 層，B1F, B2F 各層面積均為 400 平方公尺，1F, 2F 面積皆為 350 平方公尺，3~8F 皆為 280 平方公尺，依據各類場所消防安全設備設置標準之規定，下列何者正確？（1F 為地面層，BF 代表地下層，B1F 為地下 1 層，依此類推）",20,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-113-1-alarm-evacuation-017","電子工業廠房潔淨區，因潔淨環境及構造特殊，特訂定潔淨區消防安全設備設置要點，對於潔淨室設置吸氣式偵煙探測系統時，依據此設置要點，下列說明何者錯誤？",17,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-113-1-alarm-evacuation-021","一棟防火構造建築物，其中展覽室長 20 公尺、寬 20 公尺、高 6 公尺，天花板具有一個 50 公分的樑，將其平均分為兩個區域，試問使用補償式局限型一種探測器時，最少應設置幾顆探測器於該區域當中？",21,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-113-1-alarm-evacuation-016","依防災監控系統綜合操作裝置認定基準，下列那一部分非防災監控系統綜合操作裝置構成？",16,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-113-1-alarm-evacuation-022","某建築物設有火警受信總機 50 回路，竣工時實施性能試驗，於進行受信總機同時動作試驗時，使用常用電源，應將任意 X 回路設定在火警動作狀態；使用預備電源，應將任意 Y 回路設定在火警動作狀態，判定受信總機、主音響裝置、地區音響裝置、附屬裝置等性能應無異常。則 X+Y=？",22,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-112-1-alarm-evacuation-019",112,"消防安全設備及必要檢修項目檢修基準的火警自動警報設備的探測器性能檢查中，使用火焰探測器用動作試驗器，在確認火焰探測器之動作及火警分區之表示是否正常時，火焰探測器之動作時間應在幾秒內動作？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-019",111,"有關緊急照明燈的緊急電源及配線之規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-019",110,"對於設置在地下建築物、地下層及地上層三者之居室的緊急照明燈進行性能檢查，依照消防安全設備及必要檢修項目檢修基準之規定，使用低照度測定用光電管照度計測試，在地面之水平面照度應分別達多少勒克斯（lux）以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-019",109,"具閃滅或音聲引導功能之出口標示燈設置規定，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-019",108,"應設排煙設備場所之樑為裸露式者，交錯之樑形成之各防煙區劃皆應設置排煙口。但其樓地板面積每 500 平方公尺防煙區劃內，防煙壁及排煙口之設置，符合各類場所消防安全設備設置標準第 188 條第 1 項第 3 款規定，並符合下列何者，不在此限？〔A：大樑深度（cm）；B：中樑深度（cm）；X：大樑下加設之垂壁高度（cm），其值得為 0；A＋X：防煙壁下垂高度（cm）。〕",1785129962698]