[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-water-chemical-033":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-水與化學系統消防安全設備概要-033","fire-112-1-water-chemical-033",112,1,33,"二氧化碳滅火設備滅火藥劑量，下列設置規定何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"全區放射方式所需滅火藥劑量計算，設置場所為其他，150 立方公尺以上 1,500 立方公尺未滿者，每立方公尺防護區域所需滅火藥劑量為 0.9(kg\u002Fm³)","局部放射方式所需滅火藥劑量，可燃性固體或易燃性液體存放於上方開放式容器，依該防護對象表面積每 1 平方公尺以 13 公斤比例核算","移動放射方式每一具噴射瞄子所需滅火藥劑量在 90 公斤以上","全區及局部放射方式在同一建築物內有 2 個以上防護區域或防護對象時，所需滅火藥劑量應取其最大量者","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 83 條二氧化碳滅火藥劑量的全區放射級距表與局部放射核算方式。\n【正解理由】第 83 條第一款表列全區放射方式之「其他」設置場所，依防護區域體積分四段：五十立方公尺未滿為每立方公尺一點零公斤、五十立方公尺以上一百五十立方公尺未滿為零點九公斤、一百五十立方公尺以上一千五百立方公尺未滿為零點八公斤、一千五百立方公尺以上為零點七五公斤（電信機械室、總機室則為一點二公斤）。(A) 所述體積級距對應的是零點八，寫成零點九是誤植了前一級距的值；本題問錯誤者，故選 A。\n【逐項排除】\n(A) 敘述錯誤，一百五十立方公尺以上一千五百立方公尺未滿者為每立方公尺零點八公斤。\n(B) 敘述正確。第二款第一目，可燃性固體或易燃性液體存放於上方開放式容器且燃燒限於一面者，依防護對象表面積每一平方公尺以十三公斤比例核算。\n(C) 屬第 83 條移動放射方式之藥劑量規定，該款文字未落在本題所附條文範圍內，無從逐字比對，非本題所指之錯誤敘述。\n(D) 屬同條關於同一建築物內有二個以上防護區域或防護對象時取最大量之規定，同樣未落在所附條文範圍內。\n【記憶點】其他場所四級距一點零、零點九、零點八、零點七五，電信機械室與總機室一點二。","第 83 條的級距表要連著第 84 條一起記。全區放射方式除每立方公尺藥劑量外，同表另列每平方公尺開口部所需追加滅火藥劑量：電信機械室、總機室為十公斤，其餘各級距均為五公斤；滅火藥劑之基本需要量則為五十立方公尺以上一百五十立方公尺未滿五十公斤、一百五十立方公尺以上一千五百立方公尺未滿一百三十五公斤、一千五百立方公尺以上一千二百公斤。\n第 84 條規定噴頭放射壓力：滅火藥劑以常溫儲存之高壓式為每平方公分十四公斤以上，儲存於攝氏零下十八度以下之低壓式為每平方公分九公斤以上；全區放射方式的放射時間，電信機械室、總機室為三點五分鐘，其他場所為一分鐘，局部放射方式則應於三十秒內全部放射完畢。第 82 條的三種放射方式中，移動放射方式另要求皮管接頭至防護對象任一部分之水平距離在十五公尺以下。\n易混淆對照：公共危險物品等場所另有一套級距，第 222 條就防護區域體積列出未達五為一點二、五以上未達十五為一點一、十五以上未達五十為一、五十以上未達一百五十為零點九、一百五十以上未達一千五百為零點八、一千五百以上為零點七五，基本需要量分別為六、十七、五十、一百三十五、一千二百公斤，並於防護區域開口部未設自動開閉裝置時，另加算該開口部面積每平方公尺五公斤之量。兩套表適用的場所不同，作答前先確認題幹場所是否為公共危險物品場所。第 90 條的選擇閥則規定同一建築物內有二個以上防護區域或防護對象共用儲存容器時，每一防護區域或防護對象均應設置選擇閥，且設於防護區域外，並標明選擇閥字樣及所屬防護區域或防護對象。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-water-chemical-032","依各類場所消防安全設備設置標準規定，下列何者應設置消防專用蓄水池？",32,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-water-chemical-034","有關自動撒水設備免設撒水頭處所得設置補助撒水栓之規定，下列敘述何者錯誤？",34,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-water-chemical-031","消防幫浦之性能規定，下列敘述何者錯誤？",31,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-water-chemical-035","二氧化碳滅火設備之滅火藥劑儲存容器，其設置規定下列何者錯誤？",35,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-water-chemical-030","消防幫浦之防止水溫上升用排放裝置，下列敘述何者正確？",30,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-water-chemical-036","乾粉滅火設備採全區或局部之噴頭，下列設置規定何者錯誤？",36,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-033",113,"某加油站附設加氣站，其滅火器設置應符合之規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-water-chemical-033",111,"二氧化碳滅火設備配管，下列設置規定何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-water-chemical-033",110,"依消防安全設備及必要檢修項目檢修基準，滅火器設置間距規定，下列何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-water-chemical-033",109,"加壓式乾粉滅火設備應設壓力調整裝置，其可調整壓力至每平方公分多少公斤以下？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-033",108,"某百貨商場（10 樓以下）內設有一般反應型撒水頭 15 個，試問其消防幫浦最低出水量應為何？",1785129971986]