[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-water-chemical-029":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-水與化學系統消防安全設備概要-029","fire-112-1-water-chemical-029",112,1,29,"有關泡沫滅火設備，依各類場所消防安全設備設置標準規定，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"飛機庫等場所，使用泡水噴頭，並樓地板面積每九平方公尺設置 1 個","泡水噴頭放射量在每分鐘 80 公升以上","室內停車空間或汽車修理廠等場所，使用泡沫噴頭，放射區域內任一點至泡沫噴頭之水平距離在 2.1 公尺以下","使用水成膜泡沫液，泡沫噴頭每平方公尺之放射量 8 公升\u002F分鐘以上","C",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 71 條泡沫頭配置與第 72 條泡沫頭放射量的數值對照。\n【正解理由】第 71 條第二款規定室內停車空間或汽車修理廠等場所使用泡沫噴頭，並樓地板面積每九平方公尺設置一個；同條第三款規定放射區域內任一點至泡沫噴頭之水平距離在二點一公尺以下，(C) 兩項要件均與條文相符，故選 C。\n【逐項排除】\n(A) 錯誤。第一款飛機庫等場所使用泡水噴頭者，是樓地板面積每八平方公尺設置一個，每九平方公尺是第二款泡沫噴頭的配置密度。\n(B) 錯誤。第 72 條第一款泡水噴頭放射量在每分鐘七十五公升以上，不是八十公升。\n(C) 正確，室內停車空間的泡沫噴頭同時受每九平方公尺一個與水平距離二點一公尺以下兩項拘束。\n(D) 錯誤。第 72 條第二款表列樓地板面積每平方公尺之放射量為：蛋白質泡沫液六點五公升以上、合成界面活性泡沫液八公升以上、水成膜泡沫液三點七公升以上，八公升對應的是合成界面活性泡沫液。\n【記憶點】泡水噴頭八平方公尺、泡沫噴頭九平方公尺；放射量蛋白質六點五、合成界面活性八、水成膜三點七。","泡水噴頭與泡沫噴頭是兩種不同的放射器具，條文一路分流到底：泡水噴頭放射量大，用於飛機庫等大空間，第 71 條第一款每八平方公尺一個、第 72 條第一款放射量每分鐘七十五公升以上；泡沫噴頭用於室內停車空間與汽車修理廠等場所，第 71 條第二款每九平方公尺一個，放射量依泡沫原液種類查表。第 75 條的放射區域同樣分流：使用泡沫噴頭時，每一放射區域在樓地板面積五十平方公尺以上一百平方公尺以下；使用泡水噴頭時，放射區域占其樓地板面積三分之一以上且至少二百平方公尺，樓地板面積未達二百平方公尺者依實際樓地板面積計。\n第 77 條的加壓送水裝置規定，泡沫放射區域有二區域以上時，以最大一個泡沫放射區域之最低出水量加倍計算；出水壓力核算最末端一個泡沫放射區域全部泡沫噴頭放射壓力達每平方公分一公斤以上。泡沫消防栓箱則為同一樓層設一個時每分鐘一百三十公升以上、設二個以上時每分鐘二百六十公升以上。\n驗收端可對照《消防安全設備測試報告書測試方法及判定要領》泡沫滅火設備之綜合試驗：泡沫滅火藥劑之稀釋容量濃度，三％型應在三至四％範圍內、六％型應在六至八％範圍內；發泡倍率應在五倍以上；二十五％還原時間，蛋白泡沫滅火藥劑及水成膜泡沫滅火藥劑應為六十秒以上，合成界面活性劑泡沫滅火藥劑應為三十秒以上。放射量、發泡倍率與還原時間互為因果，是本設備最常見的判定考點。第 71 條第五款另規定室內停車空間有複層式停車設施者，其最上層上方之裝置面設泡沫噴頭，並延伸配管至車輛間，使能對下層停車平臺放射泡沫，但感知撒水頭之設置得免延伸配管。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-water-chemical-028","有關水霧滅火設備，依各類場所消防安全設備設置標準規定，下列敘述何者正確？",28,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-water-chemical-030","消防幫浦之防止水溫上升用排放裝置，下列敘述何者正確？",30,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-water-chemical-027","有關自動撒水設備設置流水檢知裝置規定，下列敘述何者正確？",27,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-water-chemical-031","消防幫浦之性能規定，下列敘述何者錯誤？",31,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-water-chemical-026","依據各類場所消防安全設備設置標準，有關撒水頭裝置之規定，下列敘述何者正確？",26,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-water-chemical-032","依各類場所消防安全設備設置標準規定，下列何者應設置消防專用蓄水池？",32,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-029",113,"有關流水檢知裝置之構造，依據流水檢知裝置認可基準規定，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-water-chemical-029",111,"變電站場所設置水霧滅火設備，放射區域 6 個分區，其消防幫浦出水量需達每分鐘 X 公升以上；且每顆水霧噴頭放水壓力均能達每平方公分 Y 公斤以上，請問前述 X、Y 為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-water-chemical-029",110,"公共危險物品等場所消防設計及消防安全設備，設置第五種滅火設備者，公共危險物品每達管制量之幾倍（含未滿）應有一滅火效能值？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-water-chemical-029",109,"泡沫原液與水混合使用之濃度，下列何種原液之濃度為 1%？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-029",108,"有一室內停車空間，其防護區為 25 m × 16 m × 4 m，未設自動關閉裝置之開口部面積為 10 m2，擬設置全區放射式乾粉滅火設備，試問所需法定滅火藥劑量最少為多少公斤？",1785129971961]