[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-water-chemical-019":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-水與化學系統消防安全設備概要-019","fire-112-1-water-chemical-019",112,1,19,"依各類場所消防安全設備設置標準規定，樓地板面積在 X 平方公尺以上之餐廳或供失智照顧型之長期照顧機構使用之場所且樓地板面積合計在 Y 平方公尺以上者，其廚房排油煙管及煙罩應設簡易自動滅火設備。則 X、Y 為何？",{"A":16,"B":17,"C":18,"D":19},"X=300、Y=500","X=200、Y=300","X=300、Y=200","X=200、Y=500","A",null,[],false,"本題考點：《各類場所消防安全設備設置標準》中，餐廳與長期照顧機構的廚房排油煙管及煙罩應設簡易自動滅火設備之樓地板面積門檻。\n【正解理由】依《各類場所消防安全設備設置標準》關於應設簡易自動滅火設備之規定，餐廳以樓地板面積三百平方公尺為門檻，供失智照顧型之長期照顧機構等使用之場所則以樓地板面積合計五百平方公尺為門檻，兩個門檻依用途分別認定，依序對應題目的 X 與 Y，故選 A。\n【逐項排除】\n(A) X 為三百平方公尺、Y 為五百平方公尺，與該規定就餐廳及長期照顧機構所定的兩個門檻一致。\n(B) 二百與三百都不是本規定所列的門檻值，等於把兩個門檻同時下修，餐廳與長照皆不符。\n(C) 三百雖為餐廳的門檻，但長期照顧機構的門檻被寫成二百平方公尺，Y 值不符。\n(D) 長照的五百平方公尺雖然正確，餐廳門檻卻誤植為二百平方公尺，X 值不符。\n【記憶點】餐廳三百、長照五百；設備本體規定在第一百十一條之一，警戒長度指煙罩與排油煙管接合處往內五公尺。","廚房排油煙管與煙罩是油脂沉積最嚴重的位置，油污受高溫引燃後火勢會沿管道竄延，一般滅火設備難以在管內動作，因此《各類場所消防安全設備設置標準》另立簡易自動滅火設備，並以場所用途加樓地板面積雙門檻界定應設範圍：餐廳看三百平方公尺，供失智照顧型之長期照顧機構等使用之場所看樓地板面積合計五百平方公尺。本題兩個門檻所在的應設場所條文，本文僅引至規定層級而不標條號，複習時請以《各類場所消防安全設備設置標準》應設簡易自動滅火設備之公告條文核對。\n設備本體的設置規定則明確落在第一百十一條之一，共五款：一、視排油煙管之斷面積、警戒長度及風速，配置感知元件及噴頭，其設置數量、位置及放射量應能有效滅火；二、排油煙管內風速超過每秒五公尺，應在警戒長度外側設置放出藥劑之啟動裝置及連動閉鎖閘門，但不設置閘門能有效滅火時不在此限；三、噴頭之有效射程內應涵蓋煙罩及排油煙管，且所設位置不得因藥劑之放射使可燃物有飛散之虞；四、防護範圍內之噴頭應一齊放射；五、儲存鋼瓶及加壓氣體鋼瓶設置於攝氏四十度以下之位置。同條第二項並定義警戒長度，指煙罩與排油煙管接合處往內五公尺。\n記憶時可把五個關鍵數值抓住：風速每秒五公尺、警戒長度五公尺、鋼瓶環境攝氏四十度以下、餐廳三百平方公尺、長照五百平方公尺。易混淆對照：簡易自動滅火設備防護的是煙罩與排油煙管這條線，與第十八條表列以水霧、泡沫、二氧化碳、乾粉擇一設置的鍋爐房、廚房等大量使用火源之場所（樓地板面積在二百平方公尺以上者）不是同一件事，前者防護管道與煙罩，後者防護整個場所。延伸考點連結：長期照顧機構同時是第十七條第一項第九款自動撒水設備、第十九條第一項第七款火警自動警報設備與第二十二條之一一一九火災通報裝置的應設對象，命題者常把同一類場所在不同設備的門檻放在一起考。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-water-chemical-018","乾粉滅火設備使用蓄壓用氣體容器，若氣體使用氮氣時，在溫度 35℃，大氣壓力（表壓力） 0 kg\u002Fcm2 狀態下，除加算清洗配管所需要量外，每一公斤乾粉藥劑需氮氣之量為何？",18,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-water-chemical-020","下列何種海龍替代品滅火劑，其熱分解物不至於產生氟化氫（HF）？",20,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-water-chemical-017","有關室內消防栓之水平距離、瞄子放水壓力、消防栓及位置之規定，下列敘述何者正確？",17,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-water-chemical-021","某一場所設置有滅火藥劑為 IG-01 之惰性氣體滅火設備，依據消防安全設備測試報告書測試方法及判定要領，針對儲存容器進行外觀試驗，則在室溫 35℃時，充填壓力應在多少 kgf\u002Fcm2 以下？",21,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-water-chemical-016","有關二氧化碳滅火設備構件之安全措施規定，下列敘述何者正確？",16,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-water-chemical-022","依各類場所消防安全設備設置標準規定，一般場所設置滅火器，下列敘述何者錯誤？",22,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-019",113,"關於水帶試驗，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-water-chemical-019",111,"下列有關滅火器性能檢查之敘述，何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-water-chemical-019",110,"依各類場所消防安全設備設置標準，應設置室內消防栓設備之場所，下列規定何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-water-chemical-019",109,"某室內停車空間設置低發泡固定式泡沫滅火設備，每次檢修作業時，應選擇全部放射區域數多少比例以上之放射區域進行逐區放水試驗，測其放射分布及放射壓力？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-019",108,"依各類場所消防安全設備檢修及申報作業基準，有關高壓式二氧化碳滅火藥劑儲存容器之滅火藥劑量檢查方法之注意事項中，鈷 60 有效使用年限約為多少年，如已超過時，應即時連絡專業單位處理或更換？",1785129971902]