[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-water-chemical-014":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-水與化學系統消防安全設備概要-014","fire-112-1-water-chemical-014",112,1,14,"有關二氧化碳滅火設備相關規定，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"全區放射方式用耐燃材料建造之牆、柱、樓地板或天花板等區劃間隔","全區或局部放射方式防護區域內之通風換氣裝置，應在滅火藥劑放射時停止運轉","局部放射方式所需滅火藥劑量，計算後，採高壓式應追加倍數為 1.1","移動放射方式每一具噴射瞄子所需滅火藥劑量在 90kg 以上","D",null,[],false,"本題考點：二氧化碳滅火設備之區劃材料、通風換氣裝置停止時點、局部放射追加倍數與移動放射方式藥劑量四項規定之辨正。\n【正解理由】依《各類場所消防安全設備設置標準》關於二氧化碳滅火設備移動放射方式滅火藥劑量之規定，每一具噴射瞄子所需滅火藥劑量在九十公斤以上，D 項與之相符；另三項與條文所定文字或數值不合，故選 D。\n【逐項排除】\n(A) 錯。第 82 條第一款之全區放射方式，係「用不燃材料建造之牆、柱、樓地板或天花板等區劃間隔」，本項寫成耐燃材料，材料等級用語不同。\n(B) 錯。第 85 條明定全區或局部放射方式防護區域內之通風換氣裝置，應在滅火藥劑放射「前」停止運轉；本項寫成放射時，時點延後將無法確保藥劑濃度。\n(C) 錯。第 83 條第二款第一目就上方開放式容器之局部放射方式，明定追加倍數高壓式為一點四、低壓式為一點一；本項把高壓式寫成一點一，係與低壓式混淆。\n(D) 對。移動放射方式為人員持瞄子近距離放射，其每一具噴射瞄子所需滅火藥劑量在九十公斤以上，與本項相符。\n【記憶點】二氧化碳四要點：不燃材料區劃、換氣裝置放射前停止、局部放射高壓一點四低壓一點一、移動式每具瞄子九十公斤。","二氧化碳滅火設備的三種放射方式定在第 82 條：全區放射方式須以不燃材料建造之牆、柱、樓地板或天花板等區劃間隔，且開口部設有自動關閉裝置，但能有效補充開口部洩漏量者得免設；局部放射方式視防護對象之形狀、構造、數量及性質配置噴頭；移動放射方式之皮管接頭至防護對象任一部分之水平距離在十五公尺以下。移動放射方式最容易混淆的是兩個數字：第 96 條第五款規定每一具瞄子之藥劑放射量在溫度攝氏二十度時應在每分鐘六十公斤以上，那是每分鐘的放射量；本題問的九十公斤則是每一具噴射瞄子所需的滅火藥劑總量，一個是流率、一個是總量，命題者最愛互換。\n全區放射的藥劑量依第 83 條第一款之表，電信機械室、總機室每立方公尺一點二公斤；其他場所依防護區域體積分為五十立方公尺未滿一點零、五十以上一百五十未滿零點九、一百五十以上一千五百未滿零點八、一千五百以上零點七五公斤；開口部每平方公尺追加量，電信機械室、總機室為十公斤，其他為五公斤；滅火藥劑之基本需要量則為五十、一百三十五、一千二百公斤。局部放射方式依同條第二款第一目，上方開放式容器且燃燒限於一面者，按防護對象表面積每平方公尺十三公斤核算，邊長小於零點六公尺時以零點六公尺計。\n第 84 條規定二氧化碳噴頭之放射壓力，常溫儲存之高壓式在每平方公分十四公斤以上、儲存於攝氏零下十八度以下之低壓式在每平方公分九公斤以上；放射時間為電信機械室、總機室三點五分、其他一分，局部放射則於三十秒內放射完畢。第 86 條規定開口部不得設於面對安全梯間、特別安全梯間、緊急昇降機間或其他類似場所，位於距樓地板面高度三分之二以下部分應在放射前自動關閉，未設自動關閉裝置之開口部總面積供電信機械室使用時在圍壁面積百分之一以下、其他處所在防護區域體積值或圍壁面積值二者中較小數值百分之十以下。第 94 條則要求放射之藥劑於一小時內排出，採機械排放者排風機為專用且具每小時五次之換氣量。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-water-chemical-013","依據各類場所消防安全設備設置標準規定，加氣站之滅火器設置，下列敘述何者正確？",13,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-water-chemical-015","有關滅火設備之緊急電源供電容量規定，下列敘述何者錯誤？",15,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-water-chemical-012","依據滅火器認可基準規定，由滅火器所充填之滅火藥劑量判別，下列何者屬大型滅火器？",12,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-water-chemical-016","有關二氧化碳滅火設備構件之安全措施規定，下列敘述何者正確？",16,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-water-chemical-011","建築物高度在 X 公尺以下時，其連結送水管得與室內消防栓共用立管，其管徑在 Y 毫米以上，支管管徑在 Z 毫米以上。其中 X、Y 與 Z 分別為多少？",11,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-water-chemical-017","有關室內消防栓之水平距離、瞄子放水壓力、消防栓及位置之規定，下列敘述何者正確？",17,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-014",113,"依據消防安全設備及必要檢修項目檢修基準，於檢查類似醫院之場所時，因切換成緊急電源可能會造成困擾時，得使用常用電源檢查，下列消防安全設備何者不適用此一規定？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-water-chemical-014",111,"開放式自動撒水設備之自動啟動裝置，感知撒水頭應設在裝置面距樓地板面高度多少公尺以下，且能有效探測火災處？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-water-chemical-014",110,"高壓電器設備其電壓在 7000 伏特以下時，水霧噴頭及配管與高壓電器設備應保持多少公分之標準離開距離？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-water-chemical-014",109,"測量室內消防栓瞄子直線放水之壓力時，應將壓力表之進水口，放置於瞄子前端多少距離處，讀取壓力表的指示值？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-014",108,"依各類場所消防安全設備設置標準之規定，加壓式乾粉滅火設備應設壓力調整裝置，可調整壓力至若干 MPa 以下？",1785129971862]