[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-water-chemical-010":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-水與化學系統消防安全設備概要-010","fire-112-1-water-chemical-010",112,1,10,"水霧滅火設備係利用特殊水霧噴頭，使水呈微粒霧狀及特定角度、形狀噴出，並均勻地覆蓋燃燒表面，達到滅火效果。下列何者非水霧滅火設備針對油類火災之滅火作用與原理？",{"A":16,"B":17,"C":18,"D":19},"冷卻作用","乳化作用","抑制作用","稀釋作用","C",null,[],false,"本題考點：水霧滅火設備對油類火災之滅火機制辨識，關鍵在區分物理滅火作用與化學抑制作用。\n【正解理由】水霧滅火設備以特殊水霧噴頭把水破碎成微粒霧狀噴出，《各類場所消防安全設備設置標準》第 61 條即就水霧噴頭之有效半徑在二點一公尺以下、每平方公尺放水量在每分鐘二十公升或十公升以上加以規範。水霧對油類火災之作用為冷卻、乳化與稀釋（含水蒸氣排氧之窒息）等物理作用；抑制作用係指以負觸媒捕捉燃燒連鎖反應中之自由基，屬乾粉、鹵化烴等化學滅火藥劑之機制，水霧並不具備，故選 C。\n【逐項排除】\n(A) 冷卻作用：水霧微粒總表面積大，吸收汽化潛熱迅速帶走熱量，使油面溫度降至閃火點以下，是水霧的主要滅火作用，非本題所問。\n(B) 乳化作用：水霧以適當動能衝擊油面，於油層表面形成油水乳化層，阻斷可燃蒸氣逸出，是水霧對油類火災特有之作用。\n(C) 抑制作用：又稱負觸媒作用，靠鹵素或鹼金屬離子捕捉燃燒反應之自由基，為鹵化烴與乾粉藥劑之化學滅火機制，水霧屬物理滅火，不具此作用。\n(D) 稀釋作用：水受熱汽化後體積大幅膨脹，大量水蒸氣稀釋燃燒區之氧氣與可燃蒸氣濃度，屬水霧的物理作用之一。\n【記憶點】水霧四作用為冷卻、乳化、稀釋、窒息，全屬物理；看到抑制（負觸媒）就想乾粉與鹵化烴。","水霧與撒水的差別在粒徑：撒水頭產生的是水滴，水霧噴頭以特殊構造與放水角度把水破碎成微粒；同樣一公升水，粒徑越小總表面積越大，熱交換與汽化速率越高，所以水霧的冷卻效率高於同水量的水柱。水汽化時吸收大量汽化潛熱，並在汽化後體積大幅膨脹成水蒸氣，把燃燒區的空氣推開而降低氧濃度，這就是冷卻與窒息（稀釋氧氣）兩個作用的物理來源。乳化作用則是水霧特有：微粒以適當動能打入油面，形成油與水混合的乳化層，使可燃蒸氣無法順利逸出，因此水霧可用於油類火災，而直接以水柱射入反而會濺散燃油。至於抑制作用（負觸媒、化學連鎖反應抑制），是鹵化烴與乾粉藥劑在氣相捕捉自由基而中斷連鎖反應，屬化學滅火，與水霧的物理機制分屬兩類，這正是本題的分野。\n法規面的數值一併記：第 61 條規定防護對象之總面積應在各水霧噴頭放水之有效防護範圍內，每一水霧噴頭之有效半徑在二點一公尺以下，每平方公尺放水量供第十八條附表第三項、第四項所列場所使用者在每分鐘二十公升以上，供同條附表其他場所使用者在每分鐘十公升以上；第 64 條規定水源容量二十立方公尺以上，放射區域在二區域以上者四十立方公尺以上；第 62 條規定緊急電源、配管、屋頂水箱、流水檢知裝置、啟動裝置及一齊開放閥準用第 38 條等規定。公共危險物品等場所另依第 212 條，放射區域每一區域在一百五十平方公尺以上，每平方公尺每分鐘放水量在二十公升以上，放射壓力在每平方公分三點五公斤以上。\n因為水霧常用於油類場所，第 68 條特別規範裝置水霧滅火設備之室內停車空間排水設備：車輛停駐場所地面作百分之二以上坡度、設高十公分以上之地區境界堤或深寬各十公分以上之地區境界溝、滅火坑具備油水分離裝置並設於火災不易殃及之處所、車道中央或二側設排水溝並以集水管與滅火坑相連接。含油廢水的收集與滅火原理是同一組考點。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-water-chemical-009","室外儲槽儲存閃火點在 70℃以下之第四類公共危險物品之顯著滅火困難場所，應依規定檢討設置下列何種設備？①補助泡沫消防栓 ②泡沫射水槍滅火設備 ③連結送液口 ④冷卻撒水設備 ⑤固定式泡沫滅火設備",9,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-water-chemical-011","建築物高度在 X 公尺以下時，其連結送水管得與室內消防栓共用立管，其管徑在 Y 毫米以上，支管管徑在 Z 毫米以上。其中 X、Y 與 Z 分別為多少？",11,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-water-chemical-008","某引擎試驗室設置有泡沫滅火設備，採高發泡放出口局部放射方式，依規定高發泡放出口之泡沫水溶液放射量，防護面積每 1 平方公尺應在每分鐘 X 公升以上。又防護面積係指防護對象外周線以高出防護對象物高度 Y 倍數值（該數值小於 1 公尺時，以 1 公尺計）所包圍之面積。其中 X+Y=？",8,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-water-chemical-012","依據滅火器認可基準規定，由滅火器所充填之滅火藥劑量判別，下列何者屬大型滅火器？",12,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-water-chemical-007","有關水系統滅火設備之放射（水）區域，下列敘述何者正確？",7,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-water-chemical-013","依據各類場所消防安全設備設置標準規定，加氣站之滅火器設置，下列敘述何者正確？",13,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-010",113,"有關室內消防栓測試方法及判定要領，下列何者與消防安全設備測試報告書規定不同？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-water-chemical-010",111,"樓地板面積 250 平方公尺之變壓器室，依各類場所消防安全設備設置標準規定，可選擇下列何種消防安全設備？①水霧 ②泡沫 ③二氧化碳 ④乾粉",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-water-chemical-010",110,"實施泡沫噴頭外觀檢查，應進行之項目內容不包括下列那一項？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-water-chemical-010",109,"全區放射方式之二氧化碳滅火設備，應設置從啟動裝置動作至二氧化碳放出時間至少多久的遲延裝置？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-water-chemical-010",108,"有一電信機械室，設置二氧化碳滅火設備，採全區放射方式，其所核算之滅火藥劑量應於多少秒內全部放射完畢？",1785129971845]