[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-water-chemical-002":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"水與化學系統消防安全設備概要","water-chemical","水與化學系統 · Water & Chemical","水與化學系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-水與化學系統消防安全設備概要-002","fire-112-1-water-chemical-002",112,1,2,"依公共危險物品等場所設置之滅火設備分類，自動撒水設備係屬下列何種滅火設備？",{"A":16,"B":17,"C":18,"D":19},"第一種滅火設備","第二種滅火設備","第三種滅火設備","第四種滅火設備","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 197 條公共危險物品等場所滅火設備的種別分類，判斷自動撒水設備歸屬第幾種。\n【正解理由】第 197 條第一項就公共危險物品等場所之滅火設備分類明定：第一種為室內或室外消防栓設備，第二種為自動撒水設備，第三種為水霧、泡沫、二氧化碳或乾粉滅火設備，第四種為大型滅火器，第五種為滅火器、水桶、水槽、乾燥砂、膨脹蛭石或膨脹珍珠岩。自動撒水設備逐字列於第二款，故選 B。\n【逐項排除】\n(A) 第一種依第一款為室內或室外消防栓設備，不含自動撒水設備。\n(B) 正確：第二款明定第二種滅火設備即自動撒水設備。\n(C) 第三種依第三款為水霧、泡沫、二氧化碳或乾粉滅火設備，其中水霧與泡沫屬水系、二氧化碳與乾粉屬化學系，均不含自動撒水設備。\n(D) 第四種依第四款為大型滅火器，與自動撒水設備無涉。\n【記憶點】公危場所滅火設備一到五種依序記「消防栓、自動撒水、水霧泡沫二氧化碳乾粉、大型滅火器、滅火器等第五種」。","《各類場所消防安全設備設置標準》第四編專為公共危險物品等場所而設。第 193 條先界定適用範圍，包括《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》所定之場所、加油站、加氣站、天然氣儲槽及可燃性高壓氣體儲槽、爆竹煙火製造儲存及販賣場所；第 197 條接著把滅火設備分成五種。這套「第幾種滅火設備」的講法只存在於第四編，一般場所不使用，命題時常以此設計誘答。\n分類與滅火困難等級是綁在一起考的。第 194 條界定顯著滅火困難場所、第 195 條界定一般滅火困難場所；第 201 條規定顯著滅火困難場所應依表設置第一種、第二種或第三種滅火設備，其中製造場所及一般處理場所於火災時有充滿濃煙之虞者，不得使用第一種或第三種之移動式滅火設備；第 202 條規定一般滅火困難場所設置第四種及第五種滅火設備，第五種之滅火效能值在該場所最低滅火效能值五分之一以上，室內及室外儲槽場所則設第四種及第五種各一具以上；第 203 條規定其他滅火困難場所設置第五種滅火設備，地下儲槽場所應設二具以上。\n距離規定成對出現：第 224 條第四種滅火設備距防護對象任一點之步行距離應在三十公尺以下，第 225 條第五種滅火設備至防護對象任一點之步行距離應在二十公尺以下，兩者於與其他種別併設時均有除外規定。《消防安全設備及必要檢修項目檢修基準》滅火器之外觀檢查載有相同的步行距離，並另定設有滅火器之可燃性高壓氣體儲存場所，任一點至滅火器之步行距離應在十五公尺以下。\n此外第 197 條第二項另就可燃性高壓氣體製造場所、加氣站、天然氣儲槽及可燃性高壓氣體儲槽定有防護設備分類，即冷卻撒水設備與射水設備，與第一項的五種滅火設備分屬不同體系。",true,[28,31,35,40,44,48],{"webId":29,"stem":30,"number":12,"year":11,"session":12},"fire-112-1-water-chemical-001","某一新建建築物設有室內消防栓設備，其加壓送水裝置全閉揚程為 60 公尺，今於上午 9 時施作消防立管管系加壓試驗，試驗壓力應大於 X kgf\u002Fcm2 以上之水壓，且須持續維持試驗壓力至 Y 時止均無漏水現象方為合格。其中 X 與 Y 分別為多少？",{"webId":32,"stem":33,"number":34,"year":11,"session":12},"fire-112-1-water-chemical-003","室外儲槽儲存閃火點在 70℃以下第四類公共危險物品之顯著滅火困難場所，依規定設置冷卻撒水設備，其加壓送水裝置應設置手動啟動裝置及遠隔啟動裝置。但送水區域距加壓送水裝置在多少公尺以內者，得免設遠隔啟動裝置？",3,{"webId":36,"stem":37,"number":38,"year":39,"session":12},"fire-111-1-water-chemical-040","二氧化碳滅火設備採全區放射方式，採用高壓系統在進行綜合檢查時，以空氣或氮氣進行放射試驗，所需空氣量或氮氣量，應就放射區域應設滅火藥劑量之 X%核算，每公斤核算空氣量或氮氣量 Y（公升），請問前述 X、Y 為何？",40,111,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-water-chemical-004","依水道連結型自動撒水設備設置基準之規定，採民生水箱共用式，其配管、配件及閥類之規定，下列敘述何者錯誤？",4,{"webId":45,"stem":46,"number":47,"year":39,"session":12},"fire-111-1-water-chemical-039","可燃性高壓氣體儲存場所任一點至滅火器之步行距離在 X 公尺以下，並不得妨礙出入作業；每具滅火器對普通火災具有 Y 個以上之滅火效能值，請問前述 X、Y 為何？",39,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-water-chemical-005","有關補助撒水栓與第二種室內消防栓之比較，下列敘述何者正確？",5,[53,57,60,64,68],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-water-chemical-002",113,"室內停車空間設置水霧滅火設備，依據各類場所消防安全設備設置標準規定，下列敘述何者錯誤？",{"webId":58,"year":39,"stem":59,"number":13},"fire-111-1-water-chemical-002","有關室外消防栓與室內消防栓之瞄子放水壓力之敘述，下列何者正確？",{"webId":61,"year":62,"stem":63,"number":13},"fire-110-1-water-chemical-002",110,"連結送水管之中繼幫浦放水測試時，應從送水口以送水設計壓力送水，並以口徑 21 公厘瞄子在最頂層測試，其放水壓力不得小於 X kgf\u002Fcm2，且放水量不得小於 Y L\u002Fmin。X、Y 分別為何？",{"webId":65,"year":66,"stem":67,"number":13},"fire-109-1-water-chemical-002",109,"某地下一層、地上七層建築物，地下層為室內停車空間，面積 200 平方公尺，一至七層為集合住宅，各層面積 100 平方公尺，有室內安全梯直通地下層，本案是否需設置室內消防栓設備？",{"webId":69,"year":70,"stem":71,"number":13},"fire-108-1-water-chemical-002",108,"自動撒水設備竣工時，應做加壓試驗。但密閉乾式管系應併行空氣壓試驗，試驗時，應使空氣壓力達到 X MPa 之標準，其壓力持續 Y 小時，漏氣減壓量應在 Z MPa 以下為合格。X、Y、Z 分別為何？",1785129971788]