[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-fire-science-001":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":26,"sameNumber":52,"hasEssay":25},"火災學概要","fire-science","火災學 · Fire Science","火災學",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":12,"stem":13,"options":14,"answer":19,"answerNote":20,"images":21,"imagesPending":22,"lawTimestamp":11,"explanation":23,"explanationDeep":24,"freq":12,"indexable":25},"fire-112-1-火災學概要-001","fire-112-1-fire-science-001",112,1,"建築物火災造成人命傷亡的原因，主要是煙與有毒氣體，下列何者為防煙最好的方法？",{"A":15,"B":16,"C":17,"D":18},"做好防煙區劃，阻止煙的流動","選用發煙性小的建築材料，抑制煙的發生源","使用防火閘門，做好防火區劃","設置排煙效果良好之排煙室","B",null,[],false,"本題考點：防煙對策的層級順序——抑制發生源、阻止流動、排除煙層三者何者最根本。\n【正解理由】煙控制的原理依「不讓煙產生→不讓煙擴散→把已生成的煙排掉」三個層次展開，愈接近源頭者愈根本。建築物內部裝修材料與收容物的發煙性，直接決定火災初期的產煙量、發煙速率與有毒氣體生成量；若在材料端就抑制發煙，後續區劃與排煙所要處理的煙量隨之下降，減光造成的避難障礙也同步減輕。因此防煙最好的方法是選用發煙性小的建築材料以抑制煙的發生源，故選 B。\n【逐項排除】\n(A) 做好防煙區劃，阻止煙的流動：屬第二層對策，煙已經產生，只是限制其擴散範圍；區劃有開口、氣密不足或防火門未關閉時仍會漏煙。\n(B) 選用發煙性小的建築材料，抑制煙的發生源：屬源頭管制，直接減少產煙量與毒性氣體，為最根本之防煙方法。\n(C) 使用防火閘門，做好防火區劃：防火閘門與防火區劃的主要目的是阻止火焰與熱之延燒，對煙只有附帶效果，煙粒徑細小仍可經細縫竄流。\n(D) 設置排煙效果良好之排煙室：屬第三層事後處理，須待煙已生成、探測器動作後才排除，成效還受排煙量、進風條件與緊急電源可用時間限制。\n【記憶點】防煙三段順序：先不燒出煙（材料）、再不讓煙跑（區劃）、最後才把煙趕出去（排煙）。","火災致死原因以煙與有毒氣體為主，機制有三層：一是缺氧與一氧化碳、氰化氫等毒性氣體造成生理失能；二是高溫氣體造成呼吸道灼傷；三是減光造成方向判斷失誤而延誤避難。第三項可用減光係數 Cs（單位 1\u002Fm）量化，與可見距離 D 的關係約為 D×Cs＝K（K 依標識是發光型或反射型約取 2 至 8）。一般教材以熟悉建築物者可容忍 Cs 約 0.5 1\u002Fm（可見距離數公尺），不熟悉建築物者則需 Cs 約 0.1 1\u002Fm（可見距離約二十至三十公尺）作為避難界限，這也說明為何百貨、旅館等不特定人使用場所對煙控制要求更嚴。\n煙的流動速度也解釋了為何源頭管制優先。水平方向煙流速度約每秒零點五至一公尺，與人的步行速度同級，靠區劃還能爭取時間；但在樓梯間、管道間等垂直路徑，浮力與煙囪效應使流速可達每秒三至五公尺，遠快於步行上下樓，一旦煙進入垂直豎孔，區劃與排煙都難以追上。因此把發煙量壓低，等於同時降低了浮力驅動的壓力差。\n材料端的控制在法規上有兩條線索。其一是內部裝修材料的耐燃分級，愈高級別的材料不僅不易著火，發煙性與發煙毒性也受限；其二是《各類場所消防安全設備設置標準》第 188 條第二項對防煙壁的定義——以不燃材料建造、自天花板下垂五十公分以上之垂壁（地下建築物之地下通道須下垂八十公分以上），這是把「蓄煙」與「阻止水平擴散」結合的設計；同條並規定防煙區劃內任一位置至排煙口之水平距離在三十公尺以下、排煙機排煙量在每分鐘一百二十立方公尺以上、連接緊急電源供有效動作三十分鐘以上。\n易混淆概念對照：防火區劃與防煙區劃的目的不同，前者針對火焰與熱的延燒，材料與時效是重點，後者針對煙層的水平擴散與蓄積，垂壁下垂高度與排煙口位置是重點；防火閘門是風管貫穿防火區劃時的補強元件，不是防煙的主角。相關考點還有加壓防煙的概念：在排煙室或安全梯間以進風機加壓，使煙不致侵入避難路徑，屬「阻止流動」層次的積極手法，與本題所問的源頭抑制仍屬不同層級。",true,[27,32,36,40,44,48],{"webId":28,"stem":29,"number":30,"year":31,"session":12},"fire-111-1-fire-science-040","沾有油類之毛巾，集中堆置於塑膠籃而產生自然發火，其原因為下列何者？",40,111,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-fire-science-002","下列何者屬於準自然發火性物質？",2,{"webId":37,"stem":38,"number":39,"year":31,"session":12},"fire-111-1-fire-science-039","撕下新購的電視機螢幕保護封膜時遭受靜電，其原因為下列何者？",39,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-fire-science-003","下列何者非為火災之特性？",3,{"webId":45,"stem":46,"number":47,"year":31,"session":12},"fire-111-1-fire-science-038","在長 10 m、寬 8 m、高 3 m 的居室燃燒 1 kg 的乳膠枕頭，其 Dm=0.65 m2\u002Fg，估算此火場出口標示燈能見度？",38,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-fire-science-004","若空氣中的氧氣體積百分比為 21%，則甲烷完全燃燒的化學理論濃度為多少%？",4,[53,57,61,64,68],{"webId":54,"year":55,"stem":56,"number":12},"fire-114-1-fire-science-001",114,"火場中輻射為熱傳遞主要的方式之一，輻射熱之性質及其計算的方式下列何者錯誤？",{"webId":58,"year":59,"stem":60,"number":12},"fire-113-1-fire-science-001",113,"有一倉庫長寬高分別為 8 公尺，5 公尺及 4 公尺，內置可燃物之總重量為 600 公斤，試計算該倉庫之火載量若干（kg\u002Fm2）？",{"webId":62,"year":31,"stem":63,"number":12},"fire-111-1-fire-science-001","近年來已有水滅火器經型式認可，下列敘述何者正確？",{"webId":65,"year":66,"stem":67,"number":12},"fire-110-1-fire-science-001",110,"下列物質各取 1 莫耳進行完全燃燒，何者所需的理論空氣量（kg）最少？",{"webId":69,"year":70,"stem":71,"number":12},"fire-109-1-fire-science-001",109,"已知辛烷的燃燒下限為 0.92（vol%），根據 Burgess-Wheeler 定理其燃燒熱約為多少？",1785129966417]