[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-fire-law-038":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-消防法規概要-038","fire-112-1-fire-law-038",112,1,38,"依建築技術規則建築設計施工編之規定，下列何者屬耐燃二級裝修材料？",{"A":16,"B":17,"C":18,"D":19},"耐燃合板","石膏板","耐燃纖維板","木絲水泥板","D",null,[],false,"本題考點：《建築技術規則》內部裝修材料的耐燃分級，耐燃一級、二級、三級各對應哪一類材料。\n【正解理由】依《建築技術規則建築設計施工編》第 1 條建築技術用語定義的材料分類，配合第 88 條「建築物之內部裝修材料應依下表規定」所用的耐燃一級、二級、三級體系：不燃材料為耐燃一級，耐火板為耐燃二級，耐燃材料為耐燃三級。木絲水泥板屬耐火板一類，其級別即耐燃二級，故選 D。候選原文於第 1 條該款之前截斷，此處僅依分級體系說明，不逐字補寫其定義文字。\n【逐項排除】\n(A) 耐燃合板：屬耐燃材料，級別為耐燃三級，非二級。\n(B) 石膏板：同屬耐燃材料一類，級別為耐燃三級。\n(C) 耐燃纖維板：亦列於耐燃材料，級別為耐燃三級。\n(D) 木絲水泥板：以木絲與水泥壓製，無機基材比例高，歸入耐火板，級別為耐燃二級，為本題應選者。同編第 72 條在二小時防火時效牆壁的做法中，也是把木絲水泥板搭配二面各粉厚度一公分以上之水泥砂漿、板壁總厚度在八公分以上使用。\n【記憶點】一級＝不燃材料，二級＝耐火板（木絲水泥板），三級＝耐燃材料（耐燃合板、耐燃纖維板、耐燃塑膠板、石膏板）。","耐燃分級之所以重要，是因為《建築技術規則建築設計施工編》第 88 條的內部裝修材料表就是照級別填格子的。表中以建築物類別、組別與供該用途之專用樓地板面積合計為橫軸，居室或該使用部分、通達地面之走廊及樓梯為縱軸；例如 A 類公共集會類、B 類商業類全部者，居室部分為耐燃三級以上、通達地面之走廊及樓梯為耐燃二級以上；C 類工業、倉儲類之 C-1 則居室部分即要求耐燃二級以上。同條另有兩項排除：一是除表列（十）至（十四）所列建築物及 B-1、B-2、B-3 組與 I 類外，按樓地板面積每一百平方公尺範圍內以具一小時以上防火時效之牆壁、防火門窗等防火設備與該層防火構造之樓地板區劃分隔者，或設於地面層且樓地板面積在一百平方公尺以下者；二是裝設自動滅火設備及排煙設備者。\n這條規定在消防法規裡被大量交叉引用。《各類場所消防安全設備設置標準》第 49 條第十四款第二目把「內部裝修符合建築技術規則建築設計施工編第八十八條規定」列為得免裝撒水頭的要件之一；第 159 條第四款則規定供第十二條第二款第一目、第二目、第五目、第八目或第九目所列場所使用之樓層，除符合前款規定外，設有自動撒水設備或內部裝修符合第八十八條規定者，其應設之避難器具得免設；第 159 條第五款對長期照顧、老人福利、護理機構等場所，另要求裝修材料以耐燃一級材料裝修，並設火警自動警報設備及自動撒水設備。第 190 條的免設排煙設備條件，也多以「天花板及室內牆面以耐燃一級材料裝修」為前提。\n易混淆整理：耐燃級別講的是「裝修材料」的燃燒性能，防火時效講的是「構造」抵抗火害的時間，兩者不可混為一談。同編第 72 條列的是二小時以上防火時效之牆壁、樑、柱、樓地板做法（如鋼筋混凝土造牆壁厚度十公分以上，且鋼骨混凝土造之混凝土保護層厚度三公分以上）；第 86 條規定分戶牆及分間牆構造，其中 A 類、D 類、B-1、B-2、B-4、F-1、H-1 組及總樓地板面積三百平方公尺以上之 B-3 組等，其各防火區劃內之分間牆應以不燃材料建造。看到題目給的是「材料名稱」就往耐燃級別想，給的是「厚度與時效」就往防火時效想。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-fire-law-037","依建築技術規則建築設計施工編之規定，有關建築技術用語之定義，下列敘述何者正確？",37,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-fire-law-039","依建築技術規則建築設計施工編及各類場所消防安全設備設置標準對無窗戶居室之定義及規定，下列敘述何者錯誤？",39,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-fire-law-036","依建築技術規則之定義，自室內經由陽台或排煙室始得進入之安全梯稱為下列何者？",36,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-fire-law-040","下列何者非屬行政院公共工程委員會編印之工程倫理手冊（第二版）所列，工程人員應瞭解、堅守及篤行之八大倫理基本守則之一？",40,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-fire-law-035","下列何者非屬高層建築物消防安全設備竣工查驗時應檢附之資料？",35,{"webId":49,"stem":50,"number":12,"year":51,"session":12},"fire-113-1-fire-law-001","依各類場所消防安全設備設置標準規定，防災中心樓地板面積應在多少平方公尺以上？",113,[53,57,60,64,68],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-038",114,"依消防法規定，下列敘述何者錯誤？",{"webId":58,"year":51,"stem":59,"number":13},"fire-113-1-fire-law-038","有關六類公共危險物品製造、儲存及處理場所之安全管理，下列敘述何者正確？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-fire-law-038",111,"有關加壓送水裝置之電動機，其種類、構造及機能等之敘述，何者正確？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-fire-law-038",110,"依建築技術規則建築設計施工編規定，有關防火門構造等相關規定，下列敘述何者正確？",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-fire-law-038",109,"依建築技術規則建築設計施工編之定義，經主管機關認可後，下列何者屬「防火設備」？",1785129969313]