[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-fire-law-033":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":51,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-消防法規概要-033","fire-112-1-fire-law-033",112,1,33,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"幫浦之出水量在額定出水量之 150%時，其全揚程應達到額定出水量；性能曲線上全揚程之 65%以上","減水警報之發訊裝置應採用浮筒開關或電極方式，當呼水槽水位降至其容量三分之一前，應能發出警報音響至平時有人駐在處","控制盤表示燈並區分為電源表示燈（白色）、啟動表示燈（紅色），呼水槽減水表示燈（橘黃色），電動機電流超過負載表示燈（橘黃色）","啟動用水壓開關裝置之壓力槽容量應有 100 公升以上","B",null,[],false,"本題考點：《消防幫浦加壓送水裝置等及配管摩擦損失計算基準》對幫浦性能曲線、呼水裝置減水警報、控制盤表示燈顏色與啟動用壓力槽容量的數值，四個選項各出自一個「點」。\n【正解理由】依該基準第 16 點第五款，「減水警報之發訊裝置應採用浮筒開關或電極方式，當呼水槽水位降至其容量二分之一前，應能發出警報音響至平時有人駐在處」。本項寫成降至容量三分之一前，與該款明定的二分之一不符，敘述錯誤，故選 B。\n【逐項排除】\n(A) 與第 5 點第一款「幫浦之出水量在額定出水量之 150％時，其全揚程應達到額定出水量；性能曲線上全揚程之 65％以上」相符。\n(B) 呼水槽減水警報的發訊水位是降至容量二分之一前，不是三分之一前，為本題應選者。\n(C) 與第 15 點控制盤表示燈之規定相符：電源表示燈（白色）、啟動表示燈（紅色）、呼水槽減水表示燈（橘黃色）、電動機電流超過負載表示燈（橘黃色）。\n(D) 與第 19 點第一款「啟動用壓力槽容量應有 100 公升以上」相符。\n【記憶點】呼水槽的兩個數字：有效儲存量 100 公升以上、水位降至容量二分之一前發減水警報；啟動用壓力槽容量同樣是 100 公升以上。","第 5 點的幫浦性能是三個百分數一組，要一起記：額定出水量時，性能曲線上之全揚程必須達到額定揚程之 100％至 110％之間；出水量在額定出水量之 150％時，全揚程應達到性能曲線上全揚程之 65％以上；全閉揚程應為性能曲線上全揚程之 140％以下。同點另規定吸水性能，額定出水量 900 l\u002Fmin 未滿者最大吸水全揚程 6.0 公尺、900 以上 2700 以下為 5.5 公尺、超過 2700 至 5000 以下為 4.5 公尺、超過 5000 至 8500 以下為 4.0 公尺；消耗動力則為額定出水量時軸動力不得超過馬達之額定輸出馬力，額定出水量 150％時不得超過馬達額定輸出馬力之 110％。\n第 16 點的呼水裝置宜以「六機件加三數值」記：呼水槽、溢水用排水管、補給水管（含止水閥）、呼水管（含逆止閥及止水閥）、減水警報裝置、自動給水裝置六個機件；呼水槽應有 100 公升以上之有效儲存量；水位降至其容量二分之一前應能發出警報音響至平時有人駐在處。配管管徑另有溢水用排水管 50A、補給水管 15A、呼水管 25A，而呼水槽底與呼水管逆止閥中心線間距離在 1 公尺以下時，呼水管管徑須為 40A 以上。\n第 15 點控制盤屬純記憶題：表示燈區分為電源表示燈（白色）、啟動表示燈（紅色）、呼水槽減水表示燈（橘黃色）、電動機電流超過負載表示燈（橘黃色），操作回路中使用電磁開關者之電源表示燈亦為白色；儀表應包括電流表與電壓表，但在該控制盤以外地方可辨認電壓者得免裝設；警報裝置只有馬達電流超過額定與呼水槽減水兩種，且不得有因警報鳴動而連帶使馬達自動停止之構造。第 19 點啟動用水壓開關裝置則是壓力槽容量 100 公升以上、應使用口徑 25mm 以上配管與幫浦出水側逆止閥之二次側配管連接、中途應裝置止水閥，並在壓力槽上或其近傍裝設壓力表、啟動用水壓開關及試驗幫浦啟動用之排水閥。呼水槽與啟動用壓力槽的容量都是 100 公升，是本基準最容易被改動的一組數字。",true,[28,31,35,39,43,47],{"webId":29,"stem":14,"number":30,"year":11,"session":12},"fire-112-1-fire-law-032",32,{"webId":32,"stem":33,"number":34,"year":11,"session":12},"fire-112-1-fire-law-034","避難器具支固器具以直接裝置在建築物主要構造部之施工方法，下列敘述何者正確？",34,{"webId":36,"stem":37,"number":38,"year":11,"session":12},"fire-112-1-fire-law-031","依消防安全設備及必要檢修項目檢修基準之規定，某一場所 2.5 英吋室外消防栓之瞄子口徑 19 mm，現場測得瞄子壓力為 4（kgf\u002Fcm2），其放水量計算式 Q=0.653D2 P ，試問室外消防栓瞄子放水量 Q 為多少（l\u002Fmin）？",31,{"webId":40,"stem":41,"number":42,"year":11,"session":12},"fire-112-1-fire-law-035","下列何者非屬高層建築物消防安全設備竣工查驗時應檢附之資料？",35,{"webId":44,"stem":45,"number":46,"year":11,"session":12},"fire-112-1-fire-law-030","依消防安全設備及必要檢修項目檢修基準之規定，有關惰性氣體滅火設備之綜合檢查，下列敘述何者正確？",30,{"webId":48,"stem":49,"number":50,"year":11,"session":12},"fire-112-1-fire-law-036","依建築技術規則之定義，自室內經由陽台或排煙室始得進入之安全梯稱為下列何者？",36,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-114-1-fire-law-033",114,"依六類公共危險物品製造儲存及處理場所標示板規格及設置要點規定，下列敘述何者正確？",{"webId":57,"year":58,"stem":59,"number":13},"fire-113-1-fire-law-033",113,"依建築技術規則建築設計施工編規定，下列何者不視為居室？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-fire-law-033",111,"依消防法施行細則規定，供公眾使用建築物應遴選防火管理人並制定消防防護計畫，其相關規定下列何者錯誤？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-fire-law-033",110,"依消防安全設備及必要檢修項目檢修基準規定，有關固定式泡沫滅火設備（低發泡）綜合檢查之檢查方法，下列敘述何者正確？",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-fire-law-033",109,"依各類場所消防安全設備檢修及申報作業基準之規定，各類場所之管理權人應委託檢修專業機構或消防法第 7 條規定之人員辦理檢修，並於檢修完成後多少日內，分別填具消防安全設備檢修申報表及檢附消防安全設備檢修報告書，向當地消防機關申報？",1785129969279]