[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-fire-law-029":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-消防法規概要-029","fire-112-1-fire-law-029",112,1,29,"依消防安全設備及必要檢修項目檢修基準之規定，使用加瓦斯試驗器對瓦斯漏氣火警自動警報設備的檢知器進行加瓦斯測試，若某一回路之檢知器數量為 24 個，有關該回路應選取之檢知器檢查數量，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"3個","4個","5個","6個","C",null,[],false,"本題考點：瓦斯漏氣火警自動警報設備之檢知器性能檢查，一回路檢知器選取檢查數量的級距表。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第十五章瓦斯漏氣火警自動警報設備之性能檢查，使用加瓦斯試驗器測試時，檢知器應按選取檢查數量表選取：一回路 1 至 5 個選 1 個、6 至 10 個選 2 個、11 至 15 個選 3 個、16 至 20 個選 4 個、21 至 25 個選 5 個、26 至 30 個選 6 個、30 個以上為 20％。本題一回路檢知器 24 個，落在 21 至 25 個那一格，應選取 5 個，故選 C。\n【逐項排除】\n(A) 3 個是 11 至 15 個那一格的選取數量，24 個已超過該格，取樣不足。\n(B) 4 個是 16 至 20 個那一格的選取數量，仍低於 24 個所屬級距。\n(C) 24 個落在 21 至 25 個一格，選取檢查數量為 5 個，與表列相符，為本題應選者。\n(D) 6 個是 26 至 30 個那一格的選取數量，24 個尚未達 26 個。\n【記憶點】檢知器選取數量是一格一格的級距表：21 至 25 個取 5 個；只有 30 個以上才改按 20％核算。","檢知器的性能檢查用加瓦斯試驗器加瓦斯測試，試驗瓦斯依比重選用：對空氣之比重未滿一者使用甲烷，對空氣之比重大於一者使用異丁烷。這與《各類場所消防安全設備設置標準》第 140 條所定「瓦斯」包括天然氣、液化石油氣及其他經中央主管機關指定者相呼應——天然氣輕、液化石油氣重，也決定檢知器該裝在天花板附近或地面附近。\n時間判定是另一個常考點：由動作確認燈亮燈、檢知區域警報裝置動作或加壓試驗用瓦斯起算，至受信總機瓦斯漏氣燈亮燈之時間，扣除介入中繼器的 5 秒、採第三種測法的 20 秒後，應在 60 秒內。選取檢查另有兩項注意事項：檢知器每次測試時應輪流選取，可於圖面或檢查表上註記每次選取之位置；在選取之檢知器中發現不良品時，該回路之全部檢知器均應實施檢查。\n警報裝置部分，瓦斯漏氣表示燈應無明顯劣化且正常亮燈，動作之檢知器所在位置應能容易辨識；檢知區域警報裝置的音壓應在七十分貝以上，且音色有別於其他機械噪音，綜合檢查時是在距該裝置裝設位置中心一公尺處以噪音計測定，設在箱內者保持原狀測定。綜合檢查另含同時動作（使兩個回路之任一檢知器各一個同時動作）與綜合動作（切換緊急電源後使任一檢知器動作，並得以預備電源取代緊急電源）。\n設置面則對照《設置標準》一併記：第 140 條規定瓦斯漏氣火警自動警報設備依第一百十二條之規定劃定警報分區；第 144 條規定絕緣電阻以直流五百伏特額定之絕緣電阻計測定，每一警報分區在零點一ＭΩ以上，且檢知器回路不得與本設備以外之設備回路共用；第 145 條規定緊急電源應使用蓄電池設備，容量應能使二回路有效動作十分鐘以上，其他回路能監視十分鐘以上。火警自動警報設備用的是二百五十伏特絕緣電阻計，兩者最容易互換。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-fire-law-028","經濟部輔導未登記工廠申請補辦臨時工廠登記，若該場所消防安全設備業依消防機關辦理建築物消防安全設備審查及查驗作業基準之規定完成測試，且經查驗合格，多久時間免辦理消防安全設備檢修結果申報？",28,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-fire-law-030","依消防安全設備及必要檢修項目檢修基準之規定，有關惰性氣體滅火設備之綜合檢查，下列敘述何者正確？",30,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-fire-law-027","依各類場所消防安全設備設置標準之規定，建築物總樓地板面積在多少平方公尺以上應設置防災監控系統綜合操作裝置？",27,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-fire-law-031","依消防安全設備及必要檢修項目檢修基準之規定，某一場所 2.5 英吋室外消防栓之瞄子口徑 19 mm，現場測得瞄子壓力為 4（kgf\u002Fcm2），其放水量計算式 Q=0.653D2 P ，試問室外消防栓瞄子放水量 Q 為多少（l\u002Fmin）？",31,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-fire-law-026","有關得免設排煙設備之規定，下列敘述何者正確？",26,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-fire-law-032","依消防幫浦加壓送水裝置等及配管摩擦損失計算基準之規定，下列敘述何者錯誤？",32,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-029",114,"依各類場所消防安全設備設置標準規定，下列何處所得免設排煙設備？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-029",113,"有關消防安全設備檢修申報之相關規定，下列敘述何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-029",111,"依各類場所消防安全設備設置標準規定，下列何場所之樓地板面積合計未達 1 千平方公尺，得設置水道連結型自動撒水設備或與現行法令同等以上效能之滅火設備？①產後護理之家 ②團體家屋 ③精神護理之家 ④兒童及少年福利機構",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-029",110,"有一室外儲槽，其容量為 9000 公秉，依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，設有防火水幕，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-029",109,"依消防幫浦加壓送水裝置等及配管摩擦損失計算基準，有關幫浦性能之規定，全閉揚程應為性能曲線上全揚程之多少以下？",1785129969256]