[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-fire-law-025":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-消防法規概要-025","fire-112-1-fire-law-025",112,1,25,"依各類場所消防安全設備設置標準之規定，應設置火警自動警報設備之場所及設備裝置，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"六層以上十層以下之建築物任何一層樓地板面積在 500 平方公尺以上者","應設火警自動警報設備之建築物，應劃定火警分區，每一分區之任一邊長在 50 公尺以下。但裝設光電式分離型探測器時，其邊長得在 100 公尺以下","P 型受信總機之探測器回路電阻，在 50 Ω 以下","差動式局限型探測器可以裝在高度 4 公尺以上未達 8 公尺之場所","A",null,[],false,"本題考點：應設火警自動警報設備場所的樓地板面積門檻，以及火警分區邊長、Ｐ型受信總機探測器回路電阻等裝置規定的數值辨識。\n【正解理由】依《各類場所消防安全設備設置標準》第 19 條第二款，「六層以上十層以下之建築物任何一層樓地板面積在三百平方公尺以上者」應設置火警自動警報設備。本項寫成 500 平方公尺，與條文的三百平方公尺不符，敘述錯誤，故選 A。\n【逐項排除】\n(A) 第 19 條第二款的門檻是 300 平方公尺，寫成 500 平方公尺會讓 300 至未達 500 平方公尺的樓層漏設，為本題應選者。\n(B) 與第 112 條第二款「每一分區之任一邊長在五十公尺以下。但裝設光電式分離型探測器時，其邊長得在一百公尺以下」相符。\n(C) 第 127 條第三款明定「Ｐ型受信總機之探測器回路電阻，在五十Ω以下」，敘述正確。\n(D) 依《設置標準》關於探測器裝置面高度與適用種類之規定，差動式局限型探測器適用於裝置面高度未滿八公尺之場所，四公尺以上未達八公尺仍在其適用範圍內，敘述正確。\n【記憶點】火警自動警報設備的面積門檻：五層以下依用途分 300 或 500 平方公尺，六層以上十層以下一律 300 平方公尺，十一層以上建築物全棟應設。","第 19 條的應設場所是「分層看門檻」：五層以下之建築物，供第十二條第一款及第二款第十二目所列場所使用者，任何一層樓地板面積三百平方公尺以上；供同條第二款（第十二目除外）至第四款使用者，任何一層五百平方公尺以上；六層以上十層以下之建築物，任何一層三百平方公尺以上；十一層以上建築物則全棟應設。本題把「六層以上十層以下」的三百改成五百，正是最常見的混淆——五百平方公尺是五層以下乙、丙、丁類那一段的門檻。同條第二項另有免設規定：除甲類場所、地下建築物、高層建築物或應設偵煙式探測器之場所外，已依本標準設置自動撒水、水霧或泡沫滅火設備（限使用標示攝氏溫度七十五度以下、動作時間六十秒以內之密閉型撒水頭）者，在該有效範圍內得免設。\n火警分區（第 112 條）宜五個要件一起記：每一分區不得超過一樓層且樓地板面積六百平方公尺以下，但上下二層樓地板面積之和在五百平方公尺以下者得二層共用一分區；任一邊長五十公尺以下，裝設光電式分離型探測器時得一百公尺以下；由主要出入口或直通樓梯出入口能直接觀察該樓層任一角落時，六百平方公尺得增為一千平方公尺；樓梯、斜坡通道、昇降機之昇降路及管道間在水平距離五十公尺範圍內且頂層相差二層以下者得為一火警分區；樓梯或斜坡通道垂直距離每四十五公尺以下為一火警分區。\n配線（第 127 條）的三個數值也常被互換：Ｐ型受信總機數個分區共用一公用線時，該公用線供應之分區數不得超過七個；探測器回路電阻五十Ω以下；電源回路絕緣電阻以直流二百五十伏特額定之絕緣電阻計測定，對地電壓一百五十伏特以下者零點一ＭΩ以上、超過者零點二ＭΩ以上。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-fire-law-024","某一消防設備士受託辦理一家辦公大樓消防安全設備檢修，該大樓依規定設置之全部緩降機經消防設備士執行下降檢查，測量每具緩降機之下降距離及下降時間，經計算出之平均下降速度全部符合規定，其緩降機之下降距離及下降時間，下列敘述何者正確？",24,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-fire-law-026","有關得免設排煙設備之規定，下列敘述何者正確？",26,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-fire-law-023","室外儲槽儲存閃火點在攝氏 70 度以下的第四類公共危險物品之顯著滅火困難場所，其依規定設置之冷卻撒水設備，下列敘述何者正確？",23,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-fire-law-027","依各類場所消防安全設備設置標準之規定，建築物總樓地板面積在多少平方公尺以上應設置防災監控系統綜合操作裝置？",27,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-fire-law-022","依各類場所消防安全設備設置標準應設置排煙設備之規定，下列敘述何者錯誤？",22,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-fire-law-028","經濟部輔導未登記工廠申請補辦臨時工廠登記，若該場所消防安全設備業依消防機關辦理建築物消防安全設備審查及查驗作業基準之規定完成測試，且經查驗合格，多久時間免辦理消防安全設備檢修結果申報？",28,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-025",114,"依消防設備人員法規定，有關消防設備人員的業務及責任，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-025",113,"依消防設備人員法規定，消防設備人員執業執照有效期間為幾年？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-025",111,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法，有關六類公共危險物品之販賣場所及其位置、構造及設備等規定，下列敘述何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-025",110,"某場所室內高度為 16 公尺，依各類場所消防安全設備設置標準規定，下列何者為可選擇之探測器種類？①定溫式特種 ②差動式分布型 ③光電式局限型一種 ④火焰式",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-025",109,"依各類場所消防安全設備設置標準之規定，面積 400 坪的知名餐廳，所設置滅火器核算之最低滅火效能值應為多少？",1785129969228]