[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-fire-law-018":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-消防法規概要-018","fire-112-1-fire-law-018",112,1,18,"依各類場所消防安全設備設置標準之規定，下列何類場所非屬應設置一一九火災通報裝置之場所？",{"A":16,"B":17,"C":18,"D":19},"榮譽國民之家","身心障礙者就業服務機構","療養院","養護型老人福利機構","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 22-1 條應設一一九火災通報裝置之場所，須回頭對照第 12 條的用途分類。\n【正解理由】依第 22-1 條第一款，應設一一九火災通報裝置者為供第 12 條第一款第六目所定醫院、療養院、榮譽國民之家、長期照顧服務機構、老人福利機構（限長期照護型、養護型、失智照顧型之長期照顧機構、安養機構）、護理機構、身心障礙福利機構使用之場所，均屬第 12 條第一款第六目之甲類機構；第二款則為其他經中央主管機關公告之供公眾使用之場所。身心障礙者就業服務機構列於第 12 條第二款第六目，屬乙類場所，不在第 22-1 條列舉之內，故選 B。\n【逐項排除】\n(A) 榮譽國民之家列於第 12 條第一款第六目，並為第 22-1 條第一款逐字列舉者，屬應設場所。\n(B) 身心障礙者就業服務機構列於第 12 條第二款第六目，與第 22-1 條所引之第一款第六目不同，非應設場所，為本題應選者。\n(C) 療養院列於第 12 條第一款第六目，亦為第 22-1 條第一款所列，屬應設場所。\n(D) 養護型老人福利機構落在第 22-1 條第一款括號內「老人福利機構（限長期照護型、養護型、失智照顧型之長期照顧機構、安養機構）」範圍，屬應設場所。\n【記憶點】第 22-1 條只吃第 12 條「第一款第六目」的住宿照護類甲類場所；名稱帶「就業服務」「日間照顧」者落在第二款乙類，不設。","一一九火災通報裝置是《各類場所消防安全設備設置標準》第 9 條所列警報設備五種之一（火警自動警報設備、手動報警設備、緊急廣播設備、瓦斯漏氣火警自動警報設備、一一九火災通報裝置），也是五種裡最晚納入者。它的作用是火警時把預錄訊息與場所資訊自動傳送至一一九受信單位，立法背景是照護型場所夜間人力薄弱、住民自力避難困難，通報一旦延遲就會演成大量傷亡，因此第 22-1 條的應設場所刻意鎖定第 12 條第一款第六目的醫療照護類甲類場所，再以第二款「其他經中央主管機關公告之供公眾使用之場所」保留概括授權。\n第 12 條第一款第六目與第二款第六目名稱極為近似，是本類題的固定陷阱。甲類第六目收的是住宿、養護、照顧性質者：醫院、療養院、榮譽國民之家、長期照顧服務機構（限機構住宿式、社區式之建築物使用類組非屬 H-2 之日間照顧、團體家屋及小規模多機能）、老人福利機構（限長期照護型、養護型、失智照顧型之長期照顧機構、安養機構）、兒童及少年福利機構、護理機構、身心障礙福利機構（限供住宿養護、日間服務、臨時及短期照顧者）、身心障礙者職業訓練機構（限提供住宿或使用特殊機具者）等。乙類第六目收的則是辦公室、靶場、診所、社區式且建築物使用類組屬 H-2 之日間照顧與團體家屋、日間型精神復健機構、兒童及少年心理輔導或家庭諮詢機構、身心障礙者就業服務機構、老人文康機構等。辨識訣竅是：住得下來的進甲類，白天來晚上走的落乙類。\n裝置本身的設置規定在第 145-1 條六款：應具手動及自動啟動功能；應設於值日室等經常有人之處所，設有防災中心時應設於該中心；設置遠端啟動裝置時應設有可與設置場所通話之設備；手動啟動裝置之操作開關距樓地板面之高度在零點八公尺以上一點五公尺以下；裝置附近應設置送、收話器，並與其他內線電話明確區分；應避免斜裝置並採取有效防震措施。同一組甲類第六目場所清單也出現在第 17 條第一項第九款（自動撒水設備，樓地板面積合計未達一千平方公尺者得設水道連結型自動撒水設備）與第 19 條第一項第七款（火警自動警報設備），三條併記最省力。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-fire-law-017","依各類場所消防安全設備設置標準之規定，不適用偵煙式或熱煙複合式局限型探測器之處所得選設探測器的種類，下列敘述何者正確？",17,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-fire-law-019","依各類場所消防安全設備設置標準之規定，各類場所於增建、改建或變更用途時，下列何項消防安全設備適用增建、改建或變更用途前之標準？",19,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-fire-law-016","依可燃性高壓氣體儲存場所防爆牆設置基準之規定，防爆牆應設置於堅固基礎上，其強度應能承受可能預料之氣體爆炸衝擊，下列何者非屬防爆牆種類？",16,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-fire-law-020","依各類場所消防安全設備設置標準之規定，有關避難器具之敘述，下列何者正確？",20,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-fire-law-015","依防火牆及防火水幕設置基準之規定，下列敘述何者正確？",15,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-fire-law-021","依各類場所消防安全設備設置標準，滅火設備之室內消防栓設備、室外消防栓設備、泡沫滅火設備，及防火牆及防火水幕設置基準之防火水幕設備之水源容量規定，下列敘述何者錯誤？",21,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-018",114,"依各類場所消防安全設備設置標準規定，下列何者為有效開口之必要條件？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-018",113,"依消防法第 11 條第 1 項規定，地面樓層達 11 層以上建築物、地下建築物及中央主管機關指定之場所，其管理權人應使用附有防焰標示之地毯、窗簾、布幕、展示用廣告板及其他指定之防焰物品。關於上開規定，下列敘述何者錯誤？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-018",111,"下列何者非經中央主管建築機關認定符合耐燃一級之「不因火熱引起燃燒、熔化、破裂變形及產生有害氣體」之材料？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-018",110,"第一種室內消防栓與室外消防栓之比較，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-018",109,"有一固態酒精儲槽水平剖面半徑為 10 公尺，依防火牆及防火水幕設置基準，其假想火面高度應為多少公尺？",1785129969171]