[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-fire-law-016":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-消防法規概要-016","fire-112-1-fire-law-016",112,1,16,"依可燃性高壓氣體儲存場所防爆牆設置基準之規定，防爆牆應設置於堅固基礎上，其強度應能承受可能預料之氣體爆炸衝擊，下列何者非屬防爆牆種類？",{"A":16,"B":17,"C":18,"D":19},"鋼筋混凝土製","防爆土堤製","混凝土空心磚製","鋼板製","B",null,[],false,"本題考點：可燃性高壓氣體儲存場所防爆牆之種類，屬《可燃性高壓氣體儲存場所防爆牆設置基準》所定事項。\n【正解理由】依《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》第 67 條，可燃性高壓氣體儲存場所與場外第一類、第二類保護物之安全距離，於設有防爆牆或同等以上防護性能者得予縮減，該條並明定「前項防爆牆之基準，由中央主管機關定之」，防爆牆之種類即由該基準列舉。防爆牆既須設置於堅固基礎上並承受可能預料之氣體爆炸衝擊，其種類均屬牆體構造；防爆土堤係以土方堆築之堤體，並非牆體構造，不在防爆牆種類之列，故選 B。\n【逐項排除】\n(A) 鋼筋混凝土製為牆體構造，屬防爆牆之種類。\n(B) 防爆土堤製為堤體而非牆體，不屬防爆牆之種類，為本題應選者。\n(C) 混凝土空心磚製為牆體構造，屬防爆牆之種類。\n(D) 鋼板製為牆體構造，屬防爆牆之種類。\n【記憶點】防爆牆的關鍵字是「牆」：鋼筋混凝土、混凝土空心磚、鋼板三種材料都能築成牆，土堤不是牆。\n（該基準原文未附於本題候選法源，故條號僅引至第 67 條之授權層級，把握度標為低。）","可燃性高壓氣體儲存場所的安全距離規定在《公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法》第 67 條：以儲存面積 Y 分成 0 ≦ Y ＜ 8、8 ≦ Y ＜ 25、25 ≦ Y 三段，對第一類保護物分別為 9√2、4.5√Y、22.5 公尺，對第二類保護物為 6√2、3√Y、15 公尺；設有防爆牆或同等以上防護性能者，第一類保護物縮減為 0、2.25√Y、11.25 公尺，第二類保護物縮減為 0、1.5√Y、7.5 公尺，兩表恰好各為原值之半。同條末項明定防爆牆之基準由中央主管機關定之，《可燃性高壓氣體儲存場所防爆牆設置基準》即由此授權而生，本題所問之防爆牆種類寫在該基準內。防爆牆的功能是攔阻爆炸衝擊波與飛散物，故基準要求其設置於堅固基礎上、強度能承受可能預料之氣體爆炸衝擊，種類也就限於能構成牆體者，土堤在體例上被歸為另一種防護設施。\n同一場所的相關考點集中在第 70 條的十三款構造、設備及安全管理規定：設有警戒標示及防爆型緊急照明設備；設置氣體漏氣自動警報設備；設置防止氣體滯留之有效通風裝置；採用不燃材料構造之地面一層建築物，屋頂應以輕質金屬板或其他輕質不燃材料覆蓋，屋簷距離地面二點五公尺以上；保持攝氏四十度以下之溫度且容器防止日光直射；灌氣容器與殘氣容器分開儲存並直立放置、不可重疊堆放；通路面積至少占儲存場所面積百分之二十以上；周圍二公尺範圍內嚴禁煙火且不得存放可燃性物質，但牆壁以厚度九公分以上鋼筋混凝土造或具同等以上強度構築防護牆者不在此限；避雷設備符合 CNS 一二八七二規定或以接地方式達同等以上防護性能。其中第八款但書所稱「防護牆」與本題的防爆牆是兩個不同概念，極易混為一談：前者是免除周圍二公尺禁火帶的替代措施，後者是縮減對外安全距離的構造物。此外同辦法第 60 至 62 條先把儲槽、容器、處理設備定義清楚，第 6 條第二項則把可燃性高壓氣體儲存場所界定為製造或處理場所所設置之容器儲存室，讀本章前先把這幾個定義釘住，才不會把儲槽區的規定套到容器儲存室上。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-fire-law-015","依防火牆及防火水幕設置基準之規定，下列敘述何者正確？",15,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-fire-law-017","依各類場所消防安全設備設置標準之規定，不適用偵煙式或熱煙複合式局限型探測器之處所得選設探測器的種類，下列敘述何者正確？",17,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-fire-law-014","某一室外儲槽容量為 30 公秉，其儲存閃火點在攝氏 21 度以上未達 70 度之六類公共危險物品，依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，該儲槽之周圍保留空地至少應為多少公尺以上？",14,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-fire-law-018","依各類場所消防安全設備設置標準之規定，下列何類場所非屬應設置一一九火災通報裝置之場所？",18,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-fire-law-013","依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，室內儲存場所儲存六類公共危險物品之數量，未達管制量 50 倍，且高度在 6 公尺以下者，其位置、構造及設備等規定，下列敘述何者正確？",13,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-fire-law-019","依各類場所消防安全設備設置標準之規定，各類場所於增建、改建或變更用途時，下列何項消防安全設備適用增建、改建或變更用途前之標準？",19,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-114-1-fire-law-016",114,"依消防安全設備及必要檢修項目檢修基準規定，有關火警自動警報設備綜合檢查，下列敘述何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-113-1-fire-law-016",113,"依據防火管理人訓練與專業機構登錄及管理辦法規定，下列何者不得充任防火管理人訓練講師？",{"webId":62,"year":63,"stem":64,"number":13},"fire-111-1-fire-law-016",111,"防災監控系統綜合操作裝置之緊急電源供電容量應供其有效動作多少小時以上？",{"webId":66,"year":67,"stem":68,"number":13},"fire-110-1-fire-law-016",110,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，有關六類公共危險物品之分類，下列敘述何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-109-1-fire-law-016",109,"依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，一般瓦斯行存放多少公斤以上液化石油氣，應設置漏氣警報器？",1785129969162]