[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-fire-law-004":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":51,"hasEssay":26},"消防法規概要","fire-law","消防法規 · Fire Code","消防法規",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-消防法規概要-004","fire-112-1-fire-law-004",112,1,4,"水霧滅火設備之放射區域在二區域以上時，其水源容量應保持 X 立方公尺以上；消防幫浦每分鐘出水量應為 Y 公升以上，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"X=20；Y=2500","X=40；Y=2000","X=20；Y=1500","X=40；Y=1200","B",null,[],false,"本題考點：《各類場所消防安全設備設置標準》對水霧滅火設備水源容量與加壓送水裝置出水量的規定，且放射區域在二區域以上時兩項數值均須加倍。\n【正解理由】依《各類場所消防安全設備設置標準》第64條，水霧滅火設備之水源容量應保持20立方公尺以上，但放射區域在二區域以上者，應保持40立方公尺以上；同標準第65條，加壓送水裝置之出水量每分鐘應在1200公升以上，放射區域在二區域以上者，每分鐘應在2000公升以上。題幹條件既為二區域以上，X須取40、Y須取2000，故選B。\n【逐項排除】\n(A) X=20是單一放射區域的水源容量，直接用在二區域以上會短少一半；Y=2500亦非條文所列之出水量級距，兩個數值都不成立。\n(B) 40立方公尺搭配每分鐘2000公升，正是條文對二區域以上場所所定的加倍值，水源與幫浦能力同步提升，敘述正確。\n(C) X=20同樣誤用單一放射區域的水量；Y=1500介於1200與2000之間，條文並無此門檻，屬自行編造的數值。\n(D) X=40的水源容量正確，但Y=1200是單一放射區域的出水量下限，用於二區域以上將低於法定出水量，故整組敘述仍錯。\n【記憶點】水霧放射區域一變二，「水源20變40、出水1200變2000」，水量與出水量一起翻倍記。","水霧滅火設備在《各類場所消防安全設備設置標準》第61條至第66條自成一節，設計思維與自動撒水設備不同：撒水是以較大水滴直接冷卻並潤濕可燃物，水霧則把水打散成微細水粒，靠冷卻、窒息（水汽化後體積膨脹排擠氧氣）、乳化與稀釋四種作用滅火，因此常用於停車空間、電氣設備室、危險物品場所這類不宜大量注水的空間。理解這個設計目的，就能理解為何條文要用「放射區域」而非樓地板面積來決定水量：一個放射區域代表一次同時放水的防護範圍，區域數愈多，同時放水量愈大，水源與幫浦自然要跟著加碼。\n數值上有一組必須成套記住：每一水霧噴頭之放水量在每分鐘50公升以上（第61條），放水量須使防護區域每平方公尺每分鐘達10公升以上，每一放射區域以50平方公尺以上為原則（第63條），水源容量20立方公尺、二區域以上40立方公尺（第64條），加壓送水裝置出水量每分鐘1200公升、二區域以上2000公升（第65條）。單位換算是常見陷阱：1立方公尺等於1000公升，40立方公尺即40000公升，除以每分鐘2000公升，恰可連續放水20分鐘，這正是條文水量與出水量相互對應的由來，也是驗算選項合理性的快速方法——選項中1200與40立方公尺搭配會得出33分鐘，2500與40立方公尺得16分鐘，都不符合設計上二十分鐘的一致性。\n易混淆之處在於同屬水系統的三種設備水源要求：室內消防栓為第一種每支瞄子放水量每分鐘130公升、水源以2支計算；自動撒水設備依放水壓力與撒水頭數計算水源；水霧則走「放射區域」制。另外水霧設備尚須依第66條設置排水設備，因為水霧用於停車空間時必須攔阻含油廢水，這也是常見的延伸考點。以放射區域為核心，把水源、出水量、排水三者一起背，同一條文改考任何一項都能對應。",true,[28,32,36,40,44,47],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-fire-law-003","依消防法、消防法施行細則規定之防火管理制度，下列何者非屬消防防護計畫應包括之事項？",3,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-fire-law-005","依消防法之規定，下列敘述何者正確？",5,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-fire-law-002","可燃性高壓氣體儲存場所設有符合規定之防爆牆且儲存面積為 16 平方公尺，依公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法之規定，其外牆或相當於該外牆之設施外側，與場外收容人數達 150 人之一般護理之家的安全距離至少應為多少公尺以上？",2,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-fire-law-006","依消防法及消防法施行細則之規定，下列那一個建築物或場所，遇有增建、改建、修建、室內裝修施工時，應另定施工中消防防護計畫，以監督施工單位用火、用電情形？",6,{"webId":45,"stem":46,"number":12,"year":11,"session":12},"fire-112-1-fire-law-001","針對法規、命令之敘述，下列何者錯誤？",{"webId":48,"stem":49,"number":50,"year":11,"session":12},"fire-112-1-fire-law-007","下列何者並非內政部依消防法第 12 條之規定公告應實施認可之消防機具、器材及設備，非經內政部所登錄機構之認可，並附加認可標示者，不得銷售、陳列或設置使用？",7,[52,56,60,64,68],{"webId":53,"year":54,"stem":55,"number":13},"fire-114-1-fire-law-004",114,"達管制量之公共危險物品及可燃性高壓氣體製造場所，其位置、構造、設備未符合公共危險物品及可燃性高壓氣體製造儲存處理場所設置標準暨安全管理辦法規定，處其管理權人之罰鍰為何？",{"webId":57,"year":58,"stem":59,"number":13},"fire-113-1-fire-law-004",113,"有關二氧化碳滅火設備各種標示規格，下列何者錯誤？",{"webId":61,"year":62,"stem":63,"number":13},"fire-111-1-fire-law-004",111,"國內建築型態日益多元，使災害預防及搶救複雜程度增加，下列內容何者非防災中心服勤人員訓練要點之規定？",{"webId":65,"year":66,"stem":67,"number":13},"fire-110-1-fire-law-004",110,"某 KTV 之管理權人未依規定維護該場所之消防安全設備，導致火災發生時，消防安全設備無法發揮正常功能，而造成二名消費者死亡，依消防法之規定，對管理權人之處分，下列敘述何者正確？",{"webId":69,"year":70,"stem":71,"number":13},"fire-109-1-fire-law-004",109,"依消防法施行細則之規定，針對消防安全設備施工中須經試驗或勘驗事項之查核，並製作紀錄是屬於下列那個項目之內容？",1785129969064]