[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-039":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-039","fire-112-1-alarm-evacuation-039",112,1,39,"依消防安全設備及必要檢修項目檢修基準，檢查一一九火災通報裝置性能時，有關通報裝置本體檢查，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"啟動機能檢查方法操作手動啟動裝置時，以通報裝置試驗機之報案建築物側電話機確認啟動信號送出","優先通報機能檢查方法時將連接通報裝置的電話回路以試驗機等方式成為通話狀態，操作手動啟動裝置，確認啟動狀態","通報自始播放機能檢查方法時操作手動啟動裝置以試驗機之消防機關側電話機應答，確認通報開始狀況","手動啟動裝置優先機能（有與火警自動警報設備連動者時）判定方法為當連動啟動將一區段蓄積語音送出後，再操作手動啟動裝置，應能再送出蓄積語音","A",null,[],false,"本題考點：《消防安全設備及必要檢修項目檢修基準》一一九火災通報裝置之性能檢查，通報裝置本體各項機能的檢查方法與判定方法。\n【正解理由】依該檢修基準第十六章一一九火災通報裝置之性能檢查，通報裝置本體「啟動機能」中的手動啟動裝置，檢查方法為「操作手動啟動裝置，以通報裝置試驗機之消防機關側電話機確認啟動信號送出」，判定方法為通報裝置動作時，以中文字幕或國語音效顯示。A 把確認端寫成「報案建築物側電話機」，與原文所定之消防機關側不符，故選 A。\n【逐項排除】\n(A) 手動啟動裝置之啟動機能，應以試驗機之消防機關側電話機確認啟動信號送出，本項誤植為報案建築物側，為敘述錯誤者。\n(B) 優先通報機能之檢查方法，即為將連接通報裝置的電話回路以試驗機等方式成為通話狀態，操作手動啟動裝置，確認啟動狀態，敘述正確。\n(C) 通報自始播放機能之檢查方法，即為操作手動啟動裝置，以試驗機之消防機關側電話機應答，確認通報開始狀況，敘述正確。\n(D) 手動啟動裝置優先機能之判定方法，即為因連動啟動將一區段蓄積語音送出後，再操作手動啟動裝置，應能再送出蓄積語音，敘述正確。\n【記憶點】通報裝置各項機能的確認端，站的是試驗機的「消防機關側」電話機，不是報案建築物側。","本檢修基準的體例是一、外觀檢查／二、性能檢查／三、綜合檢查，一一九火災通報裝置一章再依「預備電源」「通報裝置本體」「遠端啟動裝置等」分項展開。外觀檢查的判定方法要求：通報裝置應設在值日室等經常有人之場所，其門開關沒有障礙，裝置前應確保一公尺以上之空間，背面有門者其背面應確保檢查必要之空間；本體應貼有認可標示，各開關之名稱應無污損、不明顯部分，並應備有保險絲、燈泡等零件及回路圖、操作說明書。\n性能檢查的通報裝置本體，除本題所考的啟動機能外，尚有：保險絲類應無損傷、熔斷，且應使用回路圖所示之種類、容量；優先通報機能之判定為由接續通報裝置的電話回路應正常送出蓄積語音，該電話回路連接的電話機有使用中時，應能強制切斷並優先送出蓄積語音；通報自始播放機能之判定為蓄積語音需為自始撥放，或一區段的蓄積語音須完整、明瞭及清晰；蓄積語音訊息之判定為內容應適切；再撥號機能應能自動再撥號；通話機能則包含蓄積語音送出後之回撥應答狀況（自動開放 20 秒時間的電話回路）、不應答時的繼續通報狀態，以及切換狀況。此外另有遠端啟動裝置等之性能檢查：操作手動啟動按鈕，確認啟動信號應正常作動，有確認燈者應正常亮燈。\n設置端的依據是《各類場所消防安全設備設置標準》第 9 條（一一九火災通報裝置列為警報設備第五種）、第 22-1 條（應設場所）與第 145-1 條（應具手動及自動啟動功能、應設於值日室等經常有人之處所、設置遠端啟動裝置時應設有可與設置場所通話之設備、手動啟動裝置之操作開關距樓地板面零點八公尺以上一點五公尺以下、裝置附近應設置送收話器並與其他內線電話明確區分、應避免斜裝置並採取有效防震措施）。最易混淆的是本檢修基準與《消防安全設備測試報告書測試方法及判定要領》分屬檢修與竣工測試兩套文件，作答前先看題幹問的是檢修還是測試判定。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-038","有關通報試驗蓄積語音訊息之性能試驗，依據一一九火災通報裝置測試報告書判定要領，下列敘述何者錯誤？",38,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-040","依各類場所消防安全設備設置標準，醫院熱水室之場所適用選擇設置下列何種探測器？",40,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-037","下列何者非各類場所消防安全設備設置標準規定應設置無線電通信輔助設備之場所？",37,{"webId":41,"stem":42,"number":12,"year":43,"session":12},"fire-113-1-alarm-evacuation-001","為能有效排除火場中的濃煙，必須定期確保排煙設備之有效性，依據排煙設備檢修基準之要求，進行排煙設備的相關檢查時，下列敘述何者錯誤？",113,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-036","依消防安全設備及必要檢修項目檢修基準，有關火警自動警報設備偵煙探測器局限型，其性能檢查的敘述，下列何者正確？",36,{"webId":49,"stem":50,"number":51,"year":43,"session":12},"fire-113-1-alarm-evacuation-002","對於緊急電源插座距離樓地板的裝設高度範圍，下列何者正確？",2,[53,56,60,64,68],{"webId":54,"year":43,"stem":55,"number":13},"fire-113-1-alarm-evacuation-039","某捷運高架車站，因地形環境因素致車站早晚霧氣瀰漫，為防止霧氣結露產生探測器誤動作，選設之探測器除考量防水性能外，試問下列何者探測器不適用？",{"webId":57,"year":58,"stem":59,"number":13},"fire-111-1-alarm-evacuation-039",111,"民國 84 年取得使用執照之大樓，測試其火警地區音響裝置之音壓何者正確？",{"webId":61,"year":62,"stem":63,"number":13},"fire-110-1-alarm-evacuation-039",110,"依消防安全設備及必要檢修項目檢修基準，火焰式探測器進行性能檢查時，使用火焰探測器用動作試驗器，探測器應在多少時間內動作？",{"webId":65,"year":66,"stem":67,"number":13},"fire-109-1-alarm-evacuation-039",109,"有關緊急照明設備之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":69,"year":70,"stem":71,"number":13},"fire-108-1-alarm-evacuation-039",108,"依各類場所消防安全設備設置標準規定，下列何種場所不須設置緊急電源插座？",1785129963309]