[{"data":1,"prerenderedAt":72},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-038":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-038","fire-112-1-alarm-evacuation-038",112,1,38,"有關通報試驗蓄積語音訊息之性能試驗，依據一一九火災通報裝置測試報告書判定要領，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"手動啟動裝置部分，通報信號音為單音且連續二音並重複 1 次","手動啟動裝置部分，自動語音訊息應包含火災表示、建築物所在地址、建築物名稱、聯絡電話及結尾語（確認後請掛斷回撥）等相關內容","連動啟動部分，通報信號音為單音且連續二音並重複 2 次","連動啟動部分，自動語音訊息應表示火警自動警報設備啟動、建築物所在地址、建築物名稱、聯絡電話及結尾語（確認後請掛斷回撥）等相關內容","A",null,[],false,"本題考點：《消防安全設備測試報告書測試方法及判定要領》一一九火災通報裝置性能試驗中，蓄積語音訊息之通報信號音判定值。\n【正解理由】依該判定要領一一九火災通報裝置之通報試驗，蓄積語音訊息由通報信號音及自動語音組成，且依啟動方式分別規定：手動啟動裝置部分之通報信號音「為單音，且連續 3 音並重複 2 次」；連動啟動部分之通報信號音「為單音，且連續 2 音並重複 2 次」。A 把手動啟動裝置部分寫成「連續二音並重複 1 次」，音數與重複次數兩個數值都與判定要領不符，故選 A。\n【逐項排除】\n(A) 手動啟動裝置部分之通報信號音應為單音、連續三音並重複二次，本項寫成連續二音、重複一次，為本題所問敘述錯誤者。\n(B) 手動啟動裝置部分之自動語音訊息應包含火災表示、建築物所在地址、建築物名稱、聯絡電話及結尾語（確認後請掛斷回撥），與判定要領一致。\n(C) 連動啟動部分之通報信號音確為單音、且連續二音並重複二次，敘述正確。\n(D) 連動啟動部分之自動語音訊息應表示火警自動警報設備啟動、建築物所在地址、建築物名稱、聯絡電話及結尾語（確認後請掛斷回撥），敘述正確。\n【記憶點】手動三音、連動二音，重複次數同為二次；差別在音數，不在重複次數。","本判定要領是竣工測試填寫測試報告書時的依據，體例為甲、外觀試驗／乙、性能試驗／丙、綜合試驗，與檢修階段使用的《消防安全設備及必要檢修項目檢修基準》分屬兩份文件，項目與判定值不可互引。\n沿革上，本章修正說明載明：配合內政部一百零九年四月十七日修正發布之一一九火災通報裝置認可基準，酌修文字以統一用語，修正重點有二——一、通報試驗之蓄積語音訊息判定要領部分，於自動語音訊息增列結尾語（確認後請掛斷回撥）；二、通話試驗部分，將「回鈴」修正為「回撥」、「10 秒」修正為「20 秒」。B、D 兩個選項末尾的「確認後請掛斷回撥」，正是這次增列的內容，讀懂沿革就能判斷這兩項並非陷阱。\n同一性能試驗還有數組常考判定值：蓄積語音應在發出撥號信號並偵測應答後自動送出；每一區段之蓄積語音應在 30 秒內；自動語音訊息的內容應清楚明瞭且為電子迴路所合成之女聲發音；蓄積語音訊息應儲存於適當之記憶體中。通話試驗部分，俟一區段之蓄積語音送出並完成通話後，自動開放 20 秒時間的電話回路，從試驗機消防機關側送出回撥信號，通報裝置側之電話機回撥時，應與試驗機之消防機關側電話機相互通話；消防機關側保持不應答時，通報裝置應繼續送出蓄積語音。註記並載明，經內政部登錄機構認可通過之認可品可免除標有「＊」部分之試驗，而一區段之蓄積語音係指完整之報案語音訊息。\n設置面的依據則見《各類場所消防安全設備設置標準》第 9 條，一一九火災通報裝置為警報設備之一種；第 22-1 條定其應設場所；第 145-1 條定其設置方式，包括應具手動及自動啟動功能、應設於值日室等經常有人之處所（設有防災中心時應設於該中心）、手動啟動裝置之操作開關距離樓地板面之高度在零點八公尺以上一點五公尺以下。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-037","下列何者非各類場所消防安全設備設置標準規定應設置無線電通信輔助設備之場所？",37,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-039","依消防安全設備及必要檢修項目檢修基準，檢查一一九火災通報裝置性能時，有關通報裝置本體檢查，下列敘述何者錯誤？",39,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-036","依消防安全設備及必要檢修項目檢修基準，有關火警自動警報設備偵煙探測器局限型，其性能檢查的敘述，下列何者正確？",36,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-040","依各類場所消防安全設備設置標準，醫院熱水室之場所適用選擇設置下列何種探測器？",40,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-035","有關緊急電源插座保護箱之外觀試驗，依據緊急電源插座測試報告書判定要領，下列敘述何者錯誤？",35,{"webId":49,"stem":50,"number":12,"year":51,"session":12},"fire-113-1-alarm-evacuation-001","為能有效排除火場中的濃煙，必須定期確保排煙設備之有效性，依據排煙設備檢修基準之要求，進行排煙設備的相關檢查時，下列敘述何者錯誤？",113,[53,56,60,64,68],{"webId":54,"year":51,"stem":55,"number":13},"fire-113-1-alarm-evacuation-038","針對差動式分布型空氣管式探測器進行接點水高試驗，其試驗之目的為何？",{"webId":57,"year":58,"stem":59,"number":13},"fire-111-1-alarm-evacuation-038",111,"依消防安全設備及必要檢修項目檢修基準，針對緩降機之下降空間進行外觀檢查時，確認有無妨礙下降之物品，及有無確保下降必要之空間，下列何者錯誤？",{"webId":61,"year":62,"stem":63,"number":13},"fire-110-1-alarm-evacuation-038",110,"特別安全梯排煙室設置直接面向戶外之窗戶時，窗戶之有效開口面積應在多少平方公尺以上？",{"webId":65,"year":66,"stem":67,"number":13},"fire-109-1-alarm-evacuation-038",109,"有關應設置緊急照明設備之場所，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":69,"year":70,"stem":71,"number":13},"fire-108-1-alarm-evacuation-038",108,"依各類場所消防安全設備設置標準規定，特別安全梯及緊急昇降機間兼用排煙室時排煙閘門面積為 4 m2，忽略溫度的影響，測試點量得的平均風速 V(m\u002Fsec)應為多少以上為合格？",1785129963303]