[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-036":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-036","fire-112-1-alarm-evacuation-036",112,1,36,"依消防安全設備及必要檢修項目檢修基準，有關火警自動警報設備偵煙探測器局限型，其性能檢查的敘述，下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"光電式局限型 1 種探測器加煙後到動作之時間為 60 秒","離子式局限型 3 種探測器加煙後到動作之時間為 100 秒","光電式分離型蓄積型探測器之動作時間，應在插入減光罩後到動作之時間，應在 30 秒內加其標稱蓄積時間及 10 秒之時間內","某光電式局限型 2 種探測器其標稱蓄積時間為 25 秒，加煙後到動作之時間為 90 秒內","D",null,[],false,"本題考點：《消防安全設備及必要檢修項目檢修基準》火警自動警報設備性能檢查中，偵煙式局限型探測器加煙後動作時間之判定。\n【正解理由】該基準「二、性能檢查」探測器之「偵煙型探測器（一）局限型」判定方法明定：探測器加煙後到動作之時間，應在表 13-5 所示之時間內；蓄積型探測器之動作時間，應在表 13-5 所示之時間加其標稱蓄積時間及五秒之時間內。表 13-5 就離子式局限型與光電式局限型列出第一種 30 秒、第二種 60 秒、第三種 90 秒。光電式局限型第二種表列 60 秒，加標稱蓄積時間 25 秒，再加 5 秒，合計 90 秒，故選 D。\n【逐項排除】\n(A) 錯誤。表 13-5 所列光電式局限型第一種之動作時間為 30 秒，不是 60 秒。\n(B) 錯誤。表 13-5 所列離子式局限型第三種之動作時間為 90 秒，不是 100 秒。\n(C) 錯誤。同節「（二）分離型」明定蓄積型探測器之動作時間，應在 30 秒加其標稱蓄積時間及五秒之時間內，不是加 10 秒。\n(D) 正確。表 13-5 之 60 秒加標稱蓄積時間 25 秒，再加 5 秒，即為 90 秒內動作。\n【記憶點】偵煙局限型一二三種記 30、60、90，蓄積型再加標稱蓄積時間與 5 秒；分離型不分種別一律自 30 秒起算。","檢修基準第十三章的動作時間分寫在兩處，錨錯地方就會答錯。第一處是「二、性能檢查」的探測器：偵煙型局限型用加煙試驗器，判定依表 13-5（離子式局限型與光電式局限型第一種 30 秒、第二種 60 秒、第三種 90 秒），蓄積型再加標稱蓄積時間及五秒；分離型改用減光罩，非蓄積型 30 秒內、蓄積型 30 秒加標稱蓄積時間及五秒；火焰式探測器 30 秒內。同一節的感熱型局限型則用表 13-4，差動式局限型第一種與第二種均 30 秒、定溫式局限型特種 40 秒、第一種 60 秒、第二種 120 秒，備註載明定溫式局限型標稱動作溫度與周圍溫度之差超過五十度時動作時間得加倍計算；表 13-4 亦兼列離子式與光電式局限型 30、60、90 秒及光電式分離型 30 秒，與表 13-5 一致。第二處是「二、性能檢查」的蓄積性能（限有蓄積性能者），量的是受信總機或中繼器所設定之蓄積時間：感熱式依表 13-7 加設定蓄積時間（合計上限 20 秒），偵煙式依表 13-8（30、60、90 秒）加設定蓄積時間（合計上限 60 秒），蓄積型另加標稱蓄積時間再加 5 秒，火焰式則為 30 秒加設定蓄積時間（上限 20 秒）。本題問的是探測器本身的性能檢查，故錨在表 13-5。《消防安全設備測試報告書測試方法及判定要領》火警自動警報設備性能試驗的數值與檢修基準一致，光電式分離型同為非蓄積型 30 秒以內、蓄積型 30 秒加標稱蓄積時間及 5 秒以內。蓄積時間上限另有法源：《各類場所消防安全設備設置標準》第 125 條第一項第七款明定，受信總機、中繼器及偵煙式探測器有設定蓄積時間時，其蓄積時間之合計，每一火警分區在六十秒以下，使用其他探測器時在二十秒以下；同條第六款並規定裝置蓄積式探測器或中繼器之火警分區，該分區在受信總機不得有雙信號功能。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-035","有關緊急電源插座保護箱之外觀試驗，依據緊急電源插座測試報告書判定要領，下列敘述何者錯誤？",35,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-037","下列何者非各類場所消防安全設備設置標準規定應設置無線電通信輔助設備之場所？",37,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-034","有關無線電通信輔助設備無線電接頭之外觀試驗，依據無線電通信輔助設備測試報告書判定要領，下列敘述何者錯誤？",34,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-038","有關通報試驗蓄積語音訊息之性能試驗，依據一一九火災通報裝置測試報告書判定要領，下列敘述何者錯誤？",38,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-033","依消防安全設備及必要檢修項目檢修基準，在火警自動警報設備性能綜合檢查時，下列敘述何者錯誤？",33,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-039","依消防安全設備及必要檢修項目檢修基準，檢查一一九火災通報裝置性能時，有關通報裝置本體檢查，下列敘述何者錯誤？",39,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-036",113,"依住宅用火災警報器設置辦法規定，住宅用火災警報器應安裝於寢室、廚房、樓梯。若非屬前三類處所且任一樓層有超過 X 平方公尺之居室達 Y 間以上者，則設於走廊。則 X、Y 分別為何？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-036",111,"探測器安裝與天花板冷氣出風口應保持適當之距離，與火警探測器認可基準之下列何者有關？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-036",110,"某場所第五層需設置排煙設備，樓地板面積為 1200 平方公尺並區分為 450、400 及 350 平方公尺等三個防煙區劃，試問該層排煙機之排煙量最少應為每分鐘多少立方公尺？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-036",109,"有關定溫式感知線型探測器之外觀試驗判定要領，下列何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-036",108,"依各類場所消防安全設備設置標準第 28 條應設置排煙設備之規定，下列何者錯誤？",1785129963280]