[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-035":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-035","fire-112-1-alarm-evacuation-035",112,1,35,"有關緊急電源插座保護箱之外觀試驗，依據緊急電源插座測試報告書判定要領，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"保護箱應為嵌入式，施予防鏽加工，以厚度 1.6 毫米以上之鋼板製成者","保護箱蓋應標示「緊急電源插座」字樣，每字不得小於 1 平方公分","保護箱應設置在距離樓地板面或樓梯面之高度在 1 公尺以上 1.5 公尺以下的位置","保護箱上應設置容易開關之箱門，且內部設有防止插頭脫落之護鉤","B",null,[],false,"本題考點：《消防安全設備測試報告書測試方法及判定要領》緊急電源插座外觀試驗中，保護箱之設置場所與構造判定要領。\n【正解理由】該判定要領緊急電源插座之外觀試驗就保護箱構造定三項：應為嵌入式，施予防鏽加工，以厚度 1.6mm 以上之鋼板製成者；保護箱上應設置容易開關之箱門，且內部設有防止插頭脫落之護鉤；保護箱蓋應標示「緊急電源插座」字樣，每字不得小於二平方公分。《各類場所消防安全設備設置標準》第 191 條第四款第六目亦為每字在二平方公分以上。B 寫成 1 平方公分，低於所定字體大小，故選 B。\n【逐項排除】\n(A) 正確。保護箱為嵌入式、施予防鏽加工、以厚度 1.6mm 以上鋼板製成。\n(B) 錯誤。箱蓋字樣每字不得小於二平方公分，並非一平方公分。\n(C) 正確。保護箱應設置在距離樓地板面或樓梯面之高度在 1m 以上 1.5m 以下的位置。\n(D) 正確。箱門應容易開關，且箱內設有防止插頭脫落之護鉤。\n【記憶點】緊急電源插座保護箱：鋼板一點六毫米、高度一至一點五公尺、字大二平方公分。","《設置標準》第 191 條與判定要領緊急電源插座一章是同一套規格的兩種寫法：前者是設置時應如何做，後者是驗收時如何判定合格。第 191 條第四款把保護箱寫得極細——長邊二十五公分及短邊二十公分以上、厚度一點六毫米以上之鋼板或具同等性能以上之不燃材料製、箱內有防止插頭脫落之適當裝置（Ｌ型或Ｃ型護鉤）、箱蓋為易於開閉之構造、須接地、箱蓋標示緊急電源插座字樣每字在二平方公分以上、與室內消防栓箱等併設時須設於上方且箱蓋須能另外開啟；插座本身為接地型，裝設高度距樓地板一公尺以上一點五公尺以下，且一箱裝設二個。\n「每字二平方公分以上」這個數值極易被放大：同一部標準第 35 條室內消防栓箱之消防栓字樣為每字在二十平方公分以上，第 180 條第二款連結送水管出水口箱面之出水口字樣、第 182 條水帶箱之水帶箱字樣亦均為每字在二十平方公分以上。緊急電源插座是二平方公分，其餘幾處是二十平方公分，差一個位數，命題者最愛在此設陷阱。\n電源側規格同樣成組：電流供應容量為交流單相一百一十伏特（或一百二十伏特）十五安培，容量約一點五瓩以上；應從主配電盤設專用回路，各層至少二回路以上，每一回路連接插座數在十個以下，該專用回路不得設漏電斷路器，各插座設一百一十伏特十五安培以上之無熔絲斷路器；保護箱上方設紅色表示燈。判定要領另補上驗收面的要求：專用幹線應可供給單相交流 110V 之 15A 以上電力，分歧回路上應設置開閉器及過電流遮斷器。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-034","有關無線電通信輔助設備無線電接頭之外觀試驗，依據無線電通信輔助設備測試報告書判定要領，下列敘述何者錯誤？",34,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-036","依消防安全設備及必要檢修項目檢修基準，有關火警自動警報設備偵煙探測器局限型，其性能檢查的敘述，下列何者正確？",36,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-033","依消防安全設備及必要檢修項目檢修基準，在火警自動警報設備性能綜合檢查時，下列敘述何者錯誤？",33,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-037","下列何者非各類場所消防安全設備設置標準規定應設置無線電通信輔助設備之場所？",37,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-032","依消防機關受理消防安全設備檢修申報及複查注意事項複查作業中專業性複查，依消防安全設備及必要檢修項目檢修基準視轄區狀況，進行重點抽測，其必要抽測項目下列何者正確？",32,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-038","有關通報試驗蓄積語音訊息之性能試驗，依據一一九火災通報裝置測試報告書判定要領，下列敘述何者錯誤？",38,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-035",113,"某揚聲器額定輸出功率 10 W，量測其額定功率之音響功率位準為 98 dB，試問依緊急廣播設備用揚聲器認可基準規定，採性能設計之緊急廣播設備揚聲器，於該揚聲器上所標示之音響功率位準（1 W）應為多少 dB？",{"webId":58,"year":59,"stem":60,"number":13},"fire-110-1-alarm-evacuation-035",110,"依各類場所消防安全設備設置標準規定，避難指標設於走廊或通道時，自走廊或通道任一點至指標之步行距離在多少公尺以下？",{"webId":62,"year":63,"stem":64,"number":13},"fire-109-1-alarm-evacuation-035",109,"有關避難器具開口部周圍狀況外觀檢查之判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":66,"year":67,"stem":68,"number":13},"fire-108-1-alarm-evacuation-035",108,"依各類場所消防安全設備設置標準規定，在應設排煙設備之場所，有關其排煙設備設置之描述，下列何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-107-1-alarm-evacuation-035",107,"依各類場所消防安全設備檢修及申報作業基準規定，緊急電源插座為單相交流 110 V 者，應用額定 150 V， X 安培之接地型插座。三相交流 220 V 者則適用額定 250 V，Y 安培接地型插座，並確認應無變形、損傷、顯著腐蝕或異物阻塞等，下列何者正確？",1785129963271]