[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-034":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-034","fire-112-1-alarm-evacuation-034",112,1,34,"有關無線電通信輔助設備無線電接頭之外觀試驗，依據無線電通信輔助設備測試報告書判定要領，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"保護箱內應收納 2 公尺以上具可撓性之接續用射頻電纜","設置場所應設置於距樓地板面或基地地面高度在 0.5 公尺以上 2 公尺以下的位置","保護箱內明顯易見之位置，應標示有最大容許輸入功率、可使用之頻率域帶及注意事項","應施以防鏽處理，厚度在 1.6 毫米以上之鋼板製或具有同等以上強度者","B",null,[],false,"本題考點：《消防安全設備測試報告書測試方法及判定要領》無線電通信輔助設備外觀試驗中，無線電接頭及其保護箱之判定要領。\n【正解理由】該判定要領無線電通信輔助設備之外觀試驗，就無線電接頭之設置場所明定應設在樓地板面層消防人員可方便取用處及值日室或防災中心等平時有人之處所，並「應設置於距樓地板面或基地地面高度在 0.8m 以上 1.5m 以下的位置」；《各類場所消防安全設備設置標準》第 192 條第六款第三目亦定為零點八公尺至一點五公尺間。B 寫成 0.5 公尺以上 2 公尺以下，與判定要領不符，故選 B。\n【逐項排除】\n(A) 正確。保護箱內應收納 2m 以上具可撓性之接續用射頻電纜。\n(B) 錯誤。高度應在 0.8m 以上 1.5m 以下，並非 0.5m 以上 2m 以下。\n(C) 正確。保護箱內明顯易見之位置，應標示最大容許輸入功率、可使用之頻率域帶及注意事項。\n(D) 正確。保護箱應施以防鏽處理，厚度在 1.6mm 以上之鋼板製或具有同等以上強度者。\n【記憶點】無線電接頭高度零點八至一點五公尺，箱內射頻電纜二公尺以上。","無線電通信輔助設備與緊急電源插座同屬《設置標準》第 11 條所列消防搶救上之必要設備，應設場所見同標準第 30 條：樓高在一百公尺以上建築物之地下層、總樓地板面積在一千平方公尺以上之地下建築物、地下層在四層以上且地下層樓地板面積合計在三千平方公尺以上建築物之地下層。三款都指向地下或超高層，因為這些空間會嚴重衰減無線電波，消防隊入室後將失去通信，故以洩波同軸電纜把訊號帶進去。\n第 192 條的技術規格宜整組記：洩波同軸電纜適合傳送或輻射一百五十百萬赫（MHz）或中央主管機關指定之周波數，標稱阻抗為五十歐姆，並經耐燃處理；分配器、混合器、分波器及其他類似器具應使用介入衰耗少且接頭部分有適當防水措施者；設增輻器時其緊急電源應使用蓄電池設備，能有效動作三十分鐘以上；接頭設於地面者，在任一出入口與其他出入口之步行距離大於三百公尺時應設二個以上；接頭設於距樓地板面或基地地面高度零點八公尺至一點五公尺間，裝設於保護箱內，箱內設長度二公尺以上之射頻電纜，箱面應漆紅色並標明消防隊專用無線電接頭字樣。\n判定要領補上設置標準未寫的驗收門檻：混合器、分配器、分波器等在使用頻率域帶內電壓駐波比應為 1.5 以下，且應使用插入損失較少者；增幅器應設置在具防火區劃之防災中心或具防火性能之管道間內。《消防安全設備及必要檢修項目檢修基準》無線電通信輔助設備之外觀檢查則另要求保護箱內應無灰塵、水份侵入，設置於地面之保護箱需為不可任意開關之構造。設置、驗收、檢修三層對同一個保護箱各有要求，是本設備出題的固定套路。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-033","依消防安全設備及必要檢修項目檢修基準，在火警自動警報設備性能綜合檢查時，下列敘述何者錯誤？",33,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-035","有關緊急電源插座保護箱之外觀試驗，依據緊急電源插座測試報告書判定要領，下列敘述何者錯誤？",35,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-032","依消防機關受理消防安全設備檢修申報及複查注意事項複查作業中專業性複查，依消防安全設備及必要檢修項目檢修基準視轄區狀況，進行重點抽測，其必要抽測項目下列何者正確？",32,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-036","依消防安全設備及必要檢修項目檢修基準，有關火警自動警報設備偵煙探測器局限型，其性能檢查的敘述，下列何者正確？",36,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-031","依消防安全設備及必要檢修項目檢修基準，執行緊急廣播設備性能檢查時，對啟動裝置狀態於檢查後判定方法，下列敘述何者錯誤？",31,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-037","下列何者非各類場所消防安全設備設置標準規定應設置無線電通信輔助設備之場所？",37,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-034",113,"依據消防安全設備及必要檢修項目檢修基準，針對 119 火災通報裝置本體實施性能檢查，其中以火警自動警報設備連動啟動將一區段蓄積語音送出後，再操作手動啟動裝置，應能再送出蓄積語音，此為下列何種檢查項目？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-034",111,"二氧化碳滅火系統全區放射的空間，以往造成人員死傷之動作噴發，與防護空間下列因素何者無關？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-034",110,"依消防安全設備及必要檢修項目檢修基準，救助袋進行開口部外觀檢查時，開口部面積之限制，下列何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-034",109,"有關排煙設備綜合檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-034",108,"依各類場所消防安全設備設置標準之規定，下列何種避難器具的開口面積應為高 60 公分以上，寬 60 公分以上？",1785129963248]