[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-032":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-032","fire-112-1-alarm-evacuation-032",112,1,32,"依消防機關受理消防安全設備檢修申報及複查注意事項複查作業中專業性複查，依消防安全設備及必要檢修項目檢修基準視轄區狀況，進行重點抽測，其必要抽測項目下列何者正確？",{"A":16,"B":17,"C":18,"D":19},"對火警受信總機進行測試，用加煙（或加熱）試驗器對探測器進行動作試驗（每三層至少測試 2 個）","對瓦斯漏氣火警自動警報設備之受信總機進行測試，並用加瓦斯試驗器測試檢知器 2 個以上","對緊急廣播設備使用噪音計對每一層樓之一處揚聲器進行音壓測試（每三層至少測試 1 個）","對排煙設備使用風速計於最高樓層之機械排煙進行測試","A",null,[],false,"本題考點：《消防機關受理消防安全設備檢修申報及複查注意事項》所定專業性複查之必要抽測項目。\n【正解理由】專業性複查係由消防機關依《消防安全設備及必要檢修項目檢修基準》視轄區狀況進行重點抽測，其中火警自動警報設備之必要抽測項目，即對火警受信總機進行測試，並以加煙（或加熱）試驗器對探測器進行動作試驗，且以每三層至少測試 2 個為抽測密度。此一手法與檢修基準火警自動警報設備綜合檢查所定「使用加熱試驗器等使任一探測器動作，於受信總機確認火警分區之火災表示裝置亮燈、主音響及地區音響裝置鳴動」相合，故選 A。\n【逐項排除】\n(A) 正確。受信總機測試加上探測器動作試驗，並定每三層至少測試 2 個。\n(B) 錯誤。檢知器之取樣在檢修基準係依一回路檢知器數量之級距表決定（三十個以上取 20％），並非一律 2 個以上。\n(C) 錯誤。緊急廣播設備係對每一層樓之一處揚聲器測音壓，題敘另加「每三層至少測試 1 個」之抽樣限制，與必要抽測項目不符。\n(D) 錯誤。排煙設備風速測試之對象並非「最高樓層」之機械排煙。\n【記憶點】專業性複查主打火警設備：受信總機加探測器，每三層至少測 2 個。","複查作業分一般性複查與專業性複查：前者著重書面與外觀的形式審查，後者才由消防人員實地依《消防安全設備及必要檢修項目檢修基準》進行重點抽測。抽測而非全測，是因為檢修申報制度的第一責任人是檢修專業機構與消防設備師（士），消防機關的複查功能在於抽樣驗證檢修報告書之可信度，故必要抽測項目挑的都是「一測即知有無造假」的動作型檢查。\n須說明的是，《消防機關受理消防安全設備檢修申報及複查注意事項》係消防主管機關發布之行政規則，其各設備抽測數量應以主管機關公告之現行版本為準，本文不就其他設備之抽測個數作逐字斷言。\n可以確定的是與之呼應的檢修基準內容：火警自動警報設備綜合檢查須切換成緊急電源或預備電源供電狀態，使用加熱試驗器等使任一探測器動作，並於受信總機確認火警分區之火災表示裝置是否正常亮燈、主音響及地區音響裝置是否正常鳴動；地區音響裝置之音壓於距設置位置中心一公尺處以噪音計量測，應在九十分貝以上。瓦斯漏氣火警自動警報設備之檢知器則依表 15-2 選取檢查數量，一回路三十個以內按級距取一至六個、三十個以上取 20％，其檢知區域警報裝置音壓應在七十分貝以上；綜合檢查時使兩個回路之任一檢知器同時動作，檢知區域警報裝置音壓同為七十分貝以上。緊急廣播設備綜合檢查測揚聲器音壓，Ｌ級 92 分貝、Ｍ級 87 分貝、Ｓ級 84 分貝以上。這三組數值是複查現場最常被抽測的量測值，也是本科重複出題率最高的一組。\n設有防災中心之場所，上開受信總機多集中於同一室：《各類場所消防安全設備設置標準》第 192-1 條規定防災監控系統綜合操作裝置應設於防災中心、中央管理室或值日室等經常有人之處所，並監控或操作火警自動警報設備之受信總機、瓦斯漏氣火警自動警報設備之受信總機、緊急廣播設備之擴大機及操作裝置、排煙設備等九款設備，其緊急電源供電容量應供有效動作二小時以上。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-031","依消防安全設備及必要檢修項目檢修基準，執行緊急廣播設備性能檢查時，對啟動裝置狀態於檢查後判定方法，下列敘述何者錯誤？",31,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-033","依消防安全設備及必要檢修項目檢修基準，在火警自動警報設備性能綜合檢查時，下列敘述何者錯誤？",33,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-030","避難器具的固定架或支固器具使用螺栓固定時，若螺紋標稱為 M12×1.75 時，把螺栓埋入混凝土內不含灰漿部分之深度應為 X mm 以上，轉矩值應為 Y kgf-cm。X，Y 應各為多少？",30,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-034","有關無線電通信輔助設備無線電接頭之外觀試驗，依據無線電通信輔助設備測試報告書判定要領，下列敘述何者錯誤？",34,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-029","某建築物總樓地板面積在 5 萬平方公尺以上其主要避難路徑的地方，該出口標示燈及避難方向指示燈之緊急電源容量應在 60 分鐘以上，下列場所何者不是主要避難路徑？",29,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-035","有關緊急電源插座保護箱之外觀試驗，依據緊急電源插座測試報告書判定要領，下列敘述何者錯誤？",35,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-032",113,"依據消防安全設備及必要檢修項目檢修基準，針對瓦斯漏氣火警自動警報設備實施綜合檢查，其中切換成預備電源之狀態，使任一檢知器動作，確認其性能是否正常。此為下列何種檢查項目？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-032",111,"某場所進行緊急廣播設備綜合檢查，使用噪音計（A 特性）量測揚聲器之音壓位準，在距 L 級揚聲器 1 公尺處，音壓位準值應在 X dB 以上；又挑高空間採性能設計之指向型揚聲器，於廣播區域內任一位置距樓地板面 Y 公尺處，音壓位準值應在 Z dB 以上。則 X、Y、Z 值，下列何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-032",110,"下列有關得免設緊急照明設備之處所，何者錯誤？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-032",109,"有關無線電通信輔助設備保護箱標示之外觀檢查的判定方法，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-032",108,"下列出口標示燈及避難方向指示燈之緊急電源描述何者正確？",1785129963237]