[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-031":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-031","fire-112-1-alarm-evacuation-031",112,1,31,"依消防安全設備及必要檢修項目檢修基準，執行緊急廣播設備性能檢查時，對啟動裝置狀態於檢查後判定方法，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"手動按鈕開關在操作部應發出音響警報及火災音響信號","於受信火災信號後與火警自動警報設備之連動時，自動地啟動廣播設備，其火災音響信號或音響裝置應鳴動","在受信火災信號後與火警自動警報設備之連動時，起火層表示燈至火災信號復舊前，應保持亮燈","火警自動警報設備之手動報警機應能任意選擇通話，且此時被遮斷之緊急電話就不應聽到講話音","D",null,[],false,"本題考點：《消防安全設備及必要檢修項目檢修基準》緊急廣播設備性能檢查中，啟動裝置之判定方法。\n【正解理由】該基準緊急廣播設備性能檢查之啟動裝置一節，就「火警自動警報設備之手動報警機」定判定方法為：應能自動地進行火災廣播；操作部（主機）呼出鳴動，且應能明確相互通話；應能任意選擇通話，且此時被遮斷之緊急電話亦應能聽到講話音。D 把原文的「亦應能聽到講話音」改寫成「就不應聽到講話音」，與判定方法相反，故選 D。\n【逐項排除】\n(A) 正確。手動按鈕開關之判定方法即在操作部應發出音響警報及火災音響信號。\n(B) 正確。與火警自動警報設備連動時，於受信火災信號後應自動啟動廣播設備，其火災音響信號或音響裝置應鳴動。\n(C) 正確。連動時起火層表示燈應亮燈，且至火災信號復舊前應保持亮燈。\n(D) 錯誤。被遮斷之緊急電話仍應能聽到講話音，而非不應聽到。\n【記憶點】緊急電話可任意選擇通話，被遮斷的那一方仍聽得到講話音。","緊急廣播設備之應設場所見《各類場所消防安全設備設置標準》第 22 條：依第十九條或第二十一條規定設有火警自動警報或瓦斯漏氣火警自動警報設備之建築物，應設置緊急廣播設備。條文採「跟隨」立法，火警偵知與廣播避難成套，這也解釋了為何檢修基準的啟動裝置一節有大半篇幅在談與火警自動警報設備的連動。\n性能檢查的三組啟動裝置要分清楚：手動按鈕開關，操作後在操作部應發出音響警報及火災音響信號；火警自動警報設備之手動報警機，應自動進行火災廣播、操作部呼出鳴動並能明確相互通話、能任意選擇通話且被遮斷之緊急電話亦能聽到講話音；與火警自動警報設備之連動，應自動啟動廣播設備使火災音響信號或音響裝置鳴動、起火層表示燈亮燈並保持至火災信號復舊前。\n同一章的鳴動方式是另一個高頻考點：分區鳴動時，起火層為地上二層以上者，限該樓層與其直上二層及其直下一層鳴動；起火層為地面層者，限該樓層與其直上層及地下層各層鳴動；起火層為地下層者，限地面層及地下層各層鳴動。綜合檢查則測揚聲器音壓，於距揚聲器一公尺處以噪音計（Ａ特性）量測，Ｌ級 92 分貝以上、Ｍ級 87 分貝以上、Ｓ級 84 分貝以上。\n易混淆者為《消防安全設備測試報告書測試方法及判定要領》緊急廣播設備之性能試驗：該處要求啟動裝置操作後 10 秒以內自動依鳴動區分進行探測器發報廣播，並定明操作有二回路以上之緊急電話時在操作部應可做選擇，回路中斷之緊急電話應有語音播放。判定要領管驗收、檢修基準管定期檢修，兩套敘述各有其適用階段。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-030","避難器具的固定架或支固器具使用螺栓固定時，若螺紋標稱為 M12×1.75 時，把螺栓埋入混凝土內不含灰漿部分之深度應為 X mm 以上，轉矩值應為 Y kgf-cm。X，Y 應各為多少？",30,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-032","依消防機關受理消防安全設備檢修申報及複查注意事項複查作業中專業性複查，依消防安全設備及必要檢修項目檢修基準視轄區狀況，進行重點抽測，其必要抽測項目下列何者正確？",32,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-029","某建築物總樓地板面積在 5 萬平方公尺以上其主要避難路徑的地方，該出口標示燈及避難方向指示燈之緊急電源容量應在 60 分鐘以上，下列場所何者不是主要避難路徑？",29,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-033","依消防安全設備及必要檢修項目檢修基準，在火警自動警報設備性能綜合檢查時，下列敘述何者錯誤？",33,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-028","某一地下街其地下層設有瓦斯漏氣火警自動警報設備，其某一回路之檢知器數量有 40 個，依消防安全設備及必要檢修項目檢修基準使用「加瓦斯試驗器」進行加瓦斯測試，檢知器選取檢查數量為何？",28,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-034","有關無線電通信輔助設備無線電接頭之外觀試驗，依據無線電通信輔助設備測試報告書判定要領，下列敘述何者錯誤？",34,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-031",113,"避難器具於竣工查驗時，針對固定架或支固器具使用螺栓固定實施性能試驗，為確認螺栓對拉出之耐力，進行拉拔強度試驗。今使用直徑 10 毫米錨定螺栓，設計拉拔荷重（試驗荷重）為 960 公斤力（kgf），使用扭力扳手作為測定拉拔荷重之器具時，則鎖緊扭力應為多少公斤力-公分（kgf．cm）？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-031",111,"設置 119 火災通報裝置的主要功能為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-031",110,"一一九火災通報裝置，下列規定何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-031",109,"有關緊急照明設備性能檢查之判定方法與注意事項，下列何者與各類場所消防安全設備檢修及申報作業基準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-031",108,"依各類場所消防安全設備設置標準對於出口標示燈設置之相關規定，下列何者正確？",1785129963228]