[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-026":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-026","fire-112-1-alarm-evacuation-026",112,1,26,"依各類場所消防安全設備設置標準規定，醫院在第 3 層樓可以使用下列何種避難器具？",{"A":16,"B":17,"C":18,"D":19},"避難梯","滑杆","緩降機","滑臺","D",null,[],false,"本題考點：避難器具依設置場所與樓層別選擇設置之規定，醫院於第三層樓可採用之器具種類。\n【正解理由】依《各類場所消防安全設備設置標準》第 157 條之選設表，供第十二條第一款第六目（醫院等場所）、第二款第十二目使用之樓層，其「第三層、第四層或第五層」欄所列之避難器具為避難橋、救助袋、滑臺。題幹醫院第 3 層樓，四個選項中僅滑臺見於該欄所列器具。故選 D。\n【逐項排除】\n(A) 避難梯：該列第三層至第五層欄所列器具為避難橋、救助袋、滑臺，其中不含避難梯。\n(B) 滑杆：同欄所列器具中亦無滑杆，該器具見於第 10 條第二款之避難器具種類，但非本題樓層與場所可選設者。\n(C) 緩降機：緩降機見於該列之第二層欄，第三層至第五層欄並未列入，故不得據以選設。\n(D) 滑臺：為該列第三層至第五層欄所列器具之一，得供醫院第 3 層樓使用，敘述正確。\n【記憶點】醫院等場所之第三層，選設表所列為避難橋、救助袋、滑臺三種。","第 157 條的選設表是按「設置場所（含收容人員條件）」與「樓層」兩個維度切格的，並非所有器具在每一層都能用。樓層愈高，人員在無輔助下自行操作、垂直下降的風險愈大，因此高樓層保留下來的多是可承載多人、操作姿勢穩定的器具（避難橋、救助袋、滑臺），而需要使用者自行攀爬或懸吊的避難梯、緩降機、避難繩索、滑杆則集中在低樓層或地下層。醫院這一列所收容的是行動能力受限的病患，故第三層以上只留避難橋、救助袋、滑臺。\n同列的設置數量規定也常一併命題：第二層以上之樓層或地下層供第十二條第一款第六目、第二款第十二目使用，其收容人員在二十人（其下面樓層供第十二條第一款第一目至第五目、第七目、第二款第二目、第六目、第七目、第三款第三目或第四款所列場所使用時，應為十人）以上一百人以下時設一具；超過一百人時，每增加（包含未滿）一百人增設一具。括號內的十人門檻是漏抄的常見失分點。\n上位規定方面，第 10 條第二款把避難器具定義為滑臺、避難梯、避難橋、救助袋、緩降機、避難繩索、滑杆及其他避難器具；第 25 條規定建築物除十一層以上樓層及避難層外，各樓層應選設上開器具或經中央主管機關認可具同等性能之避難器具，但建築物在構造及設施上並無避難逃生障礙並經中央主管機關認可者，不在此限。\n選定器具後，開口與操作空間也要一起查。第 162 條開口面積規定：緩降機、避難梯、避難繩索及滑杆為高八十公分以上、寬五十公分以上，或高一百公分以上、寬四十五公分以上；救助袋為高六十公分以上、寬六十公分以上；滑臺為高八十公分以上、寬為滑臺最大寬度以上；避難橋為高一百八十公分以上、寬為避難橋最大寬度以上。第 163 條操作面積規定：緩降機、避難梯、避難繩索及滑杆為零點五平方公尺以上（不含避難器具所佔面積）且邊長應為六十公分以上；救助袋為寬一百五十公分以上、長一百五十公分以上（含器具所佔面積），但無操作障礙且操作面積在二點二五平方公尺以上時不在此限；滑臺、避難橋則依避難器具大小及形狀留置。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-025","有關發電機設備設置場所之外觀試驗，依據緊急電源（發電機設備）測試報告書判定要領，下列敘述何者錯誤？",25,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-027","依各類場所消防安全設備設置標準之規定，有關緊急電源插座之設置場所與位置規定，下列敘述何者錯誤？",27,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-024","排煙設備中以不燃材料建造的防煙壁，在某百貨公司的二樓售貨區其防煙壁自天花板下垂 X 公分以上，另臺北市的火車站前地下街（地下建築物）之地下通道，其防煙壁應自天花板下垂 Y 公分以上。X、Y 應各為多少才合規定？",24,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-028","某一地下街其地下層設有瓦斯漏氣火警自動警報設備，其某一回路之檢知器數量有 40 個，依消防安全設備及必要檢修項目檢修基準使用「加瓦斯試驗器」進行加瓦斯測試，檢知器選取檢查數量為何？",28,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-023","有關特別安全梯或緊急昇降機間排煙室之排煙設備，當設置直接面向戶外之窗戶時，下列敘述何者錯誤？",23,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-029","某建築物總樓地板面積在 5 萬平方公尺以上其主要避難路徑的地方，該出口標示燈及避難方向指示燈之緊急電源容量應在 60 分鐘以上，下列場所何者不是主要避難路徑？",29,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-026",113,"依規定出口標示燈及避難方向指示燈，應保持不熄滅。惟為配合政府機關推動節能減碳措施，除上述燈具採用省電產品外，出口標示燈及走廊通道避難方向指示燈，符合下列何者規定，得予減光或消燈？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-026",111,"因疫情消毒需求，某醫院院區之一間獨立庫房存放 75%酒精之備用囤放量遽增，下列何因素使該庫房須設置火警自動警報設備移報至火警總機？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-026",110,"對於單相交流 110 V 之緊急電源插座進行外觀及性能檢查時，下列何者與消防安全設備及必要檢修項目檢修基準之規定不同？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-026",109,"有關緊急廣播設備配線之設置，除依屋內線路裝置規則外，下列何者與各類場所消防安全設備設置標準之規定不同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-026",108,"依各類場所消防安全設備設置標準規定，裝置面高度 10 公尺者，不可選擇下列何種探測器設置？",1785129963162]