[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-023":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-023","fire-112-1-alarm-evacuation-023",112,1,23,"有關特別安全梯或緊急昇降機間排煙室之排煙設備，當設置直接面向戶外之窗戶時，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"特別安全梯排煙室與緊急昇降機間兼用時，窗戶之有效開口面積在 2 平方公尺以上","在排煙時窗戶與煙接觸部分使用不燃材料","窗戶有效開口面積位於天花板高度二分之一以上之範圍內","平時關閉之窗戶設手動開關裝置，其操作部分設於距離樓地板面 80 公分以上 150 公分以下之牆面，並標示簡易之操作方式","A",null,[],false,"本題考點：特別安全梯或緊急昇降機間排煙室之排煙設備，採「設置直接面向戶外之窗戶」這條路徑時的四項規定。\n【正解理由】依《各類場所消防安全設備設置標準》第 189 條第一款第三目，窗戶之有效開口面積在二平方公尺以上，「但特別安全梯排煙室與緊急昇降機間兼用時（以下簡稱兼用），應在三平方公尺以上」。兼用時之門檻為三平方公尺以上，本題問敘述錯誤者。故選 A。\n【逐項排除】\n(A) 兼用時之窗戶有效開口面積依同目但書應在三平方公尺以上，本項寫二平方公尺以上，把單獨使用的值套到兼用情形，敘述錯誤，為本題所問者。\n(B) 同款第一目明定在排煙時窗戶與煙接觸部分使用不燃材料，敘述正確。\n(C) 同款第二目明定窗戶有效開口面積位於天花板高度二分之一以上之範圍內，敘述正確。\n(D) 同款第四目明定平時關閉之窗戶設手動開關裝置，其操作部分設於距離樓地板面八十公分以上一百五十公分以下之牆面，並標示簡易之操作方式，敘述正確。\n【記憶點】排煙室窗戶有效開口面積，單獨使用二平方公尺以上、兼用三平方公尺以上，操作部分八十至一百五十公分。","第 189 條是「依下列規定選擇設置」的條文，第一款窗戶與第二款排煙、進風風管是兩條互斥路徑，題幹寫「設置直接面向戶外之窗戶時」就只看第一款，四個選項也正好對應第一款的四目。答這類題最忌把第二款的數值挪到第一款來用。\n第二款那條路徑的數值可以整組對照著記：排煙口位於天花板高度二分之一以上之範圍內，與直接連通戶外之排煙風管連接並接排煙機；進風口位於天花板高度二分之一以下之範圍內，其直接面向戶外者開口面積在一平方公尺（兼用時為一點五平方公尺）以上，或與直接連通戶外之進風風管連接並接進風機；排煙機、進風機之排煙量、進風量在每秒四立方公尺（兼用時每秒六立方公尺）以上，且可隨排煙口、進風口開啟而自動啟動；相關設備連接緊急電源，供電容量應供有效動作三十分鐘以上。可以看出「兼用」在本條是一個系統性的加成條件，窗戶二變三、進風口一變一點五、風量四變六。\n建築端另有平行規定。《建築技術規則建築設計施工編》第 102 條就排煙室規定：應設置可開向戶外之窗戶，面積不得小於二平方公尺，二者兼用時不得小於三平方公尺，並應位於天花板高度二分之一以上範圍內；未設該窗戶時應開設面積四平方公尺以上（兼排煙室使用時六平方公尺以上）之排煙口並直接連通排煙管道，排煙管道內部斷面積不得小於六平方公尺（兼用時九平方公尺）；進風口開口面積不得小於一平方公尺（兼用時一點五平方公尺），進風管道斷面積不得小於二平方公尺（兼用時三平方公尺）；設有每秒可進、排四立方公尺以上並可自動操作之進風機、排煙機者，得不受部分款項限制。\n驗收端的《消防安全設備測試報告書測試方法及判定要領》第十七章排煙設備丙、綜合試驗，對排煙室設置直接開向戶外之窗戶時所列判定要領，與第 189 條第一款四目逐項相同，包含窗戶有效開口面積不得小於二平方公尺、兼用時不得小於三平方公尺。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-022","有關感熱型探測器定溫式（非再用型）性能檢查之選取檢查數量，依據火警自動警報設備檢修基準，下列敘述何者錯誤？",22,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-024","排煙設備中以不燃材料建造的防煙壁，在某百貨公司的二樓售貨區其防煙壁自天花板下垂 X 公分以上，另臺北市的火車站前地下街（地下建築物）之地下通道，其防煙壁應自天花板下垂 Y 公分以上。X、Y 應各為多少才合規定？",24,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-021","依各類場所消防安全設備設置標準之規定，裝設於樓梯 L 級揚聲器，距揚聲器 1 公尺處所測得之音壓規定，下列何者正確？",21,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-025","有關發電機設備設置場所之外觀試驗，依據緊急電源（發電機設備）測試報告書判定要領，下列敘述何者錯誤？",25,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-020","依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",20,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-026","依各類場所消防安全設備設置標準規定，醫院在第 3 層樓可以使用下列何種避難器具？",26,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-023",113,"依各類場所消防安全設備設置標準規定，下列何場所或建築物未達應設置火警自動警報設備條件？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-023",111,"火焰探測器偵測火災為偵測火場的何種參數？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-023",110,"依各類場所消防安全設備設置標準，火警探測器之探測區域係指裝置面之四周以淨高 X 公分以上之樑或類似構造體區劃包圍者。偵煙式探測器，其裝置面之四周淨高應為 Y 公分，其中 X 及 Y 分別為：",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-023",109,"有關地下建築物總樓地板面積在幾平方公尺以上應設置無線電通信輔助設備，下列何者與各類場所消防安全設備設置標準之規定相同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-023",108,"偵煙式局限型探測器裝設於防火構造建築物天花板高度 8 公尺之裝置面時，若樓地板面積為 500 平方公尺，且其天花板中間有一下垂 40 公分的樑隔開，試問至少須設置幾個偵煙式局限型 1 種探測器？",1785129963145]