[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-022":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-022","fire-112-1-alarm-evacuation-022",112,1,22,"有關感熱型探測器定溫式（非再用型）性能檢查之選取檢查數量，依據火警自動警報設備檢修基準，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"探測器之設置數量 1 個以上 10 個以下，選取檢查數量 1 個","探測器之設置數量 11 個以上 50 個以下，選取檢查數量 2 個","探測器之設置數量 51 個以上 100 個以下，選取檢查數量 3 個","探測器之設置數量 101 個以上，選取檢查數量 7 個","C",null,[],false,"本題考點：定溫式（非再用型）局限型感熱型探測器實施性能檢查時，依設置數量抽取之選取檢查數量。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第十三章火警自動警報設備二、性能檢查，定溫式（非再用型）局限型探測器係按表 13-3 選取檢查數量後，依再用型探測器之方式進行加熱試驗；該表所列為設置數量 1 以上 10 以下選取 1 個、11 以上 50 以下選取 2 個、51 以上 100 以下選取 4 個、101 以上選取 7 個。題目問敘述錯誤者，51 個以上 100 個以下應選取 4 個而非 3 個。故選 C。\n【逐項排除】\n(A) 設置數量 1 個以上 10 個以下選取 1 個，與表 13-3 所列相符，敘述正確。\n(B) 設置數量 11 個以上 50 個以下選取 2 個，與表 13-3 所列相符，敘述正確。\n(C) 設置數量 51 個以上 100 個以下，表 13-3 所列為選取 4 個，本項寫 3 個，敘述錯誤，為本題所問者。\n(D) 設置數量 101 個以上選取 7 個，與表 13-3 所列相符，敘述正確。\n【記憶點】非再用型定溫式之選取檢查數量依序為 1、2、4、7 個，對應 10 個以下、50 個以下、100 個以下與 101 個以上。","為什麼定溫式探測器要分再用型與非再用型兩套檢查方式？定溫式局限型常見的感熱元件之一是低熔點金屬熔片，動作一次即熔斷、無法復歸，屬非再用型；一旦加熱試驗就等於報廢該顆探測器。全數試驗成本過高，所以檢修基準改採抽樣：定溫式及差動式（再用型）以加熱試驗器逐一加熱，確認動作時間及警戒區域表示是否正常；定溫式（非再用型）則先按表 13-3 抽取數量，再依再用型之要領加熱。\n表 13-3 的四個級距與抽取個數（1、2、4、7）是本科的高頻考點，命題方式幾乎固定為抽換中間那一格，本題動的就是 51 以上 100 以下這一列。值得注意的是《消防安全設備測試報告書測試方法及判定要領》第九章火警自動警報設備乙、性能試驗，對定溫式局限型（非再用型）動作試驗所列的抽取個數表同樣是 1 以上 10 以下抽 1、11 以上 50 以下抽 2、51 以上 100 以下抽 4、101 以上抽 7，兩份文件在這一組數字上一致，可以互相印證。\n抽出來之後要看的是動作時間。測試要領同章所列定溫式局限型之動作時間為特種 40 秒、第一種 60 秒、第二種 120 秒，並附但書：標稱動作溫度和周圍溫度的差超過 50 度時，得將動作時間設定為 2 倍之值；差動式局限型與補償式局限型則為第一種、第二種各 30 秒。檢修基準蓄積性能判定的表 13-7 也是同一組數值。\n易混淆的是另一張抽樣表。蓄積性能檢查用的是表 13-6，按火警分區數抽樣：50 以下者感熱式、偵煙式、火焰探測器各選定 1 個，51 以上者各選定 2 個。一張看設置數量、一張看火警分區數，用途不同，答題時先確認題幹問的是哪一種檢查。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-021","依各類場所消防安全設備設置標準之規定，裝設於樓梯 L 級揚聲器，距揚聲器 1 公尺處所測得之音壓規定，下列何者正確？",21,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-023","有關特別安全梯或緊急昇降機間排煙室之排煙設備，當設置直接面向戶外之窗戶時，下列敘述何者錯誤？",23,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-020","依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",20,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-024","排煙設備中以不燃材料建造的防煙壁，在某百貨公司的二樓售貨區其防煙壁自天花板下垂 X 公分以上，另臺北市的火車站前地下街（地下建築物）之地下通道，其防煙壁應自天花板下垂 Y 公分以上。X、Y 應各為多少才合規定？",24,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-019","消防安全設備及必要檢修項目檢修基準的火警自動警報設備的探測器性能檢查中，使用火焰探測器用動作試驗器，在確認火焰探測器之動作及火警分區之表示是否正常時，火焰探測器之動作時間應在幾秒內動作？",19,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-025","有關發電機設備設置場所之外觀試驗，依據緊急電源（發電機設備）測試報告書判定要領，下列敘述何者錯誤？",25,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-022",113,"某建築物設有火警受信總機 50 回路，竣工時實施性能試驗，於進行受信總機同時動作試驗時，使用常用電源，應將任意 X 回路設定在火警動作狀態；使用預備電源，應將任意 Y 回路設定在火警動作狀態，判定受信總機、主音響裝置、地區音響裝置、附屬裝置等性能應無異常。則 X+Y=？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-022",111,"避難器具安裝完成實施性能試驗，針對支固器具進行荷重試驗，緩降機至少應載重 X kg 以上；救助袋應載重 Y kg 以上，試問 X、Y 分別為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-022",110,"有一地下 3 層、地上 7 層之建築物，各層樓地板面積為 600 平方公尺，若地下 1 樓發生火警，則火警自動警報設備之鳴動樓層，下列何者正確？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-022",109,"有關使用瓦斯之場所供各類場所消防安全設備設置標準第 12 條第 5 款第 1 目使用之地下層，其樓地板面積合計 X 平方公尺以上，且其中甲類場所樓地板面積合計 Y 平方公尺以上者，應設置瓦斯漏氣火警自動警報設備，下列何者與該設置標準之規定相同？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-022",108,"依照各類場所消防安全設備檢修及申報作業基準之規定，會結露之場所適用的探測器為下列何者？",1785129963135]