[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-018":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-018","fire-112-1-alarm-evacuation-018",112,1,18,"消防安全設備及必要檢修項目檢修基準的緊急照明設備於性能檢查時，判定方法下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"在照度上於地下建築物之地下通道，緊急照明燈在地面之水平面照度應達到二勒克斯（lux）以上","在檢查開關切斷常用電源時，應能自動切換至緊急電源，即時亮燈；復舊時，要用手動切換回常用電源","緊急電源其電源容量應能持續 20 分鐘以上","檢查開關切斷常用電源時，即時亮燈後，保險絲類應無損傷或熔斷之情形","D",null,[],false,"本題考點：《消防安全設備及必要檢修項目檢修基準》緊急照明設備性能檢查之判定方法，四個選項分屬照度、檢查開關、緊急電源與保險絲類四組判定值。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》第十九章緊急照明設備二、性能檢查之判定方法，「保險絲類」一項明定「應無損傷或熔斷之情形」「應為規定之種類及容量」，與選項所述之檢查結果相符。故選 D。\n【逐項排除】\n(A) 同章判定方法「照度」明定於地下建築物之地下通道，緊急照明燈在地面之水平面照度應達十勒克斯（lux）以上，其他場所始為二勒克斯以上；本項把地下通道寫成二勒克斯，數值誤植。\n(B) 同章判定方法「檢查開關」明定切斷常用電源時應能自動切換至緊急電源、即時亮燈，復舊時「亦能自動切換回常用電源」，並非以手動切換回常用電源。\n(C) 同章判定方法「緊急電源」明定電源容量應能持續三十分鐘以上，本項寫 20 分鐘，時間不足。\n(D) 與該章保險絲類之判定方法逐字相符，敘述正確。\n【記憶點】緊急照明設備性能檢查：地下通道十勒克斯、其他場所二勒克斯，緊急電源三十分鐘，切換與復舊都是自動。","檢修基準的判定值不是憑空訂的，而是回頭對應《各類場所消防安全設備設置標準》的設置規定。第 178 條明定緊急照明燈在地面之水平面照度，使用低照度測定用光電管照度計測得之值，在地下建築物之地下通道應在十勒克司（Lux）以上，其他場所應在二勒克司以上，且走廊曲折點處應增設緊急照明燈；第 177 條則明定緊急電源應使用蓄電池設備，容量應能使其持續動作三十分鐘以上，採蓄電池設備與緊急發電機併設方式時，容量應分別能持續動作十分鐘及三十分鐘以上。檢修基準第十九章的照度與緊急電源判定方法，正是這兩條的檢查版本。\n容易混淆的是驗收端。《消防安全設備測試報告書測試方法及判定要領》第十四章緊急照明設備乙、性能試驗，要求切換為緊急電源狀態亮燈經過三十分鐘後再以低照度測定用光電管照度計測試，其判定為地下建築物之地下通道應達十勒克斯以上、其他場所應達一勒克斯以上（日光燈型應達二勒克斯以上），並在走廊曲折處增設。設置端、檢修端、驗收端三份文件的體例與部分數值並不相同，題幹寫哪一份就查哪一份，這是本科最常見的陷阱設計。\n另一個常考點是同章注意事項的檢查數量，它是級距表而非比例：建築物總樓地板面積 1000 平方公尺以下檢查 5 個以上、3000 平方公尺以下 10 個以上、6000 平方公尺以下 15 個以上、10000 平方公尺以下 20 個以上，超過 10000 平方公尺者為 20 個加上每增加 5000 平方公尺增加 5 個。把它記成「每若干平方公尺抽幾個」的比例會在中間級距算錯。\n性能檢查的六個項目也值得整組背：照度、檢查開關、保險絲類、結線接續、緊急電源，加上注意事項的檢查數量規定。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-017","有一地下建築物總樓地板面積超過 1 千平方公尺，依據各類場所消防安全設備設置標準，下列何者非依法應設之消防安全設備？",17,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-019","消防安全設備及必要檢修項目檢修基準的火警自動警報設備的探測器性能檢查中，使用火焰探測器用動作試驗器，在確認火焰探測器之動作及火警分區之表示是否正常時，火焰探測器之動作時間應在幾秒內動作？",19,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-016","有關光電式分離型探測器設置規定，依據各類場所消防安全設備設置標準，下列敘述何者錯誤？",16,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-020","依各類場所消防安全設備設置標準之規定，下列敘述何者正確？",20,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-015","有關消防安全設備緊急電源容量，依據各類場所消防安全設備設置標準，下列敘述何者錯誤？",15,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-021","依各類場所消防安全設備設置標準之規定，裝設於樓梯 L 級揚聲器，距揚聲器 1 公尺處所測得之音壓規定，下列何者正確？",21,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-018",113,"探測器容易因設置環境影響其探測能力，因此需考慮設置處所環境，根據各類場所消防安全設備設置標準之要求，補償式局限型二種探測器不適合安裝在下列場所？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-018",111,"局限型偵煙探測器光電式的偵測原理若設計為散亂光式，其對火場中何種信號較不敏感？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-018",110,"下列避難器具架設完成後，進行綜合檢查時，何者應判定不合格？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-018",109,"依住宅用火災警報器認可基準之規定，住宅用火災警報器以警報音發出火災警報，於無響室中距離警報器中心前方 1 公尺處，音壓應有多少分貝以上？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-018",108,"利用加瓦斯試驗器對瓦斯漏氣檢知器進行檢測，其性能判定方法下列何者錯誤？",1785129963082]