[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-014":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-014","fire-112-1-alarm-evacuation-014",112,1,14,"依各類場所消防安全設備設置標準規定，火警自動警報設備應採分區鳴動，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"總樓地板面積 5 千平方公尺之 8 層樓建築物，應採分區鳴動","總樓地板面積 2 千平方公尺之 3 層樓建築物，應採全區鳴動","採分區鳴動時，鳴動於 10 分鐘內或受信總機再接受火災信號時，應立即全區鳴動","起火層為地下層時，限該樓層與其直上 2 層及其直下層鳴動","D",null,[],false,"本題考點：《各類場所消防安全設備設置標準》第 113 條，火警自動警報設備採分區鳴動的要件與各起火層之鳴動範圍。\n【正解理由】第 113 條本文定分區鳴動之適用要件為「建築物在五樓以上，且總樓地板面積在三千平方公尺以上者」，其第三款明定「起火層為地下層時，限地面層及地下層各層鳴動」。選項所述「限該樓層與其直上 2 層及其直下層鳴動」，是同條第一款「起火層為地上二層以上時」的鳴動範圍，把它套到起火層為地下層的情形與條文不符，故選 D。\n【逐項排除】\n(A) 正確：8 層樓且總樓地板面積 5 千平方公尺，同時滿足五樓以上與三千平方公尺以上兩項要件，應採分區鳴動。\n(B) 正確：3 層樓、總樓地板面積 2 千平方公尺，兩項要件均未滿足，不適用第 113 條之分區鳴動，即為全區鳴動。\n(C) 正確：第 113 條第四款明定前三款之鳴動於十分鐘內或受信總機再接受火災信號時，應立即全區鳴動。\n(D) 錯誤：起火層為地下層時，鳴動範圍為地面層及地下層各層，不是該樓層與其直上二層及其直下層。\n【記憶點】分區鳴動三句話：地上二層以上起火，該層加直上二層加直下層；地面層起火，該層加直上層加地下層各層；地下層起火，地面層加地下層各層。","分區鳴動的立法目的，是避免全棟同時鳴動使各層人員一起湧入樓梯而阻塞避難動線，因此先讓受火煙威脅最急迫的樓層鳴動；為了不讓其他樓層一直被蒙在鼓裡，第 113 條第四款再加一道保險：前三款之鳴動於十分鐘內，或受信總機再接受火災信號時，應立即全區鳴動。同一套鳴動區分在其他法源也各有出處，可互相印證：《消防安全設備及必要檢修項目檢修基準》火警自動警報設備之性能檢查，音響裝置判定方法載明「建築物在五層以上，且總樓地板面積超過三千平方公尺者，其地區音響裝置應依下列所示分區鳴動，必要時可以手動操作一齊鳴動」，並列出起火層為地上二層以上時限該樓層與其直上兩層及其直下層鳴動、起火層為地面層時限該樓層與其直上層及地下層各層鳴動、起火層為地下層時限地面層及地下層各層鳴動；同基準緊急廣播設備之性能檢查，揚聲器鳴動方式的判定也是相同的三種區分。火警分區的劃定則看第 112 條：每一火警分區不得超過一樓層，並在樓地板面積六百平方公尺以下，但上下二層樓地板面積之和在五百平方公尺以下者得二層共用一分區；每一分區之任一邊長在五十公尺以下，但裝設光電式分離型探測器時，其邊長得在一百公尺以下；由主要出入口或直通樓梯出入口能直接觀察該樓層任一角落時，六百平方公尺得增為一千平方公尺；樓梯或斜坡通道，垂直距離每四十五公尺以下為一火警分區，但其地下層部分應為另一火警分區。答題時務必先驗「五樓以上」與「三千平方公尺以上」兩要件，要件不成立就沒有分區鳴動的問題。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-013","有關避難器具設置規定，依據各類場所消防安全設備設置標準，下列何種避難器具不能裝置在使用場所之樑？",13,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-015","有關消防安全設備緊急電源容量，依據各類場所消防安全設備設置標準，下列敘述何者錯誤？",15,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-012","有關出口標示燈及避難方向指示燈，在沒有不易看清或識別該燈情形的條件，依據各類場所消防安全設備設置標準，下列有效範圍何者錯誤？",12,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-016","有關光電式分離型探測器設置規定，依據各類場所消防安全設備設置標準，下列敘述何者錯誤？",16,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-011","依據火警探測器認可基準之構造及材質規定，下列敘述何者錯誤？",11,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-017","有一地下建築物總樓地板面積超過 1 千平方公尺，依據各類場所消防安全設備設置標準，下列何者非依法應設之消防安全設備？",17,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-014",113,"某社區活動中心位於建築物第 2 層（非避難層），經檢討該活動中心為有開口樓層，依規定自活動中心任一點易於觀察識別其主要出入口，且與主要出入口之步行距離分別在 X 公尺以下，得免設出口標示燈；步行距離在 Y 公尺以下，得免設避難方向指示燈，則 X+Y=？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-014",111,"依各類場所消防安全設備設置標準規定，供失智照顧型長期照顧服務機構、老人福利機構（安養機構）、產後護理機構等避難弱勢場所之樓層，符合規定者得免設避難器具，下列何者非免設之必要條件？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-014",110,"對火警自動警報設備二信號式受信總機進行火災表示之性能檢查時，接到第 1 報火警信號但尚未接到第 2 報火警信號時，下列那二種裝置均不應動作？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-014",109,"某百貨商場之 5 樓樓地板面積為 2,100 平方公尺，依各類場所消防安全設備設置標準規定，該層樓至少應設置幾個防煙區劃？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-014",108,"緊急照明設備性能試驗之水平面照度測試，切換為緊急電源狀態亮燈，經過 A 分鐘後，使用 B 測試，確認緊急照明燈之照度有無達到法規所規定之值。請問前述 A、B 為何？",1785129963040]