[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-010":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-010","fire-112-1-alarm-evacuation-010",112,1,10,"依據緊急照明設備檢修基準性能檢查之判定方法，有關檢查緊急電源容量能否持續 30 分鐘之檢查數量，下列敘述何者正確？",{"A":16,"B":17,"C":18,"D":19},"建築物總樓地板面積 1 千平方公尺以下，檢查數量 5 個以上","建築物總樓地板面積 3 千平方公尺以下，檢查數量 8 個以上","建築物總樓地板面積 6 千平方公尺以下，檢查數量 10 個以上","建築物總樓地板面積 1 萬平方公尺以下，檢查數量 15 個以上","A",null,[],false,"本題考點：緊急照明設備性能檢查中，「緊急電源容量能否持續三十分鐘」之抽查數量級距表。\n【正解理由】依《消防安全設備及必要檢修項目檢修基準》緊急照明設備之性能檢查，緊急電源之判定方法為電源容量應能持續三十分鐘以上，其注意事項並以建築物總樓地板面積訂出檢查數量級距表：1000 平方公尺以下為 5 個以上、3000 平方公尺以下為 10 個以上、6000 平方公尺以下為 15 個以上、10000 平方公尺以下為 20 個以上，超過 10000 平方公尺者為 20 個加上每增加 5000 平方公尺增加 5 個。選項所載「總樓地板面積 1 千平方公尺以下、檢查數量 5 個以上」與該表逐字相符，故選 A。\n【逐項排除】\n(A) 正確：總樓地板面積 1000 平方公尺以下者，檢查數量為 5 個以上。\n(B) 錯誤：3000 平方公尺以下者為 10 個以上，非 8 個以上。\n(C) 錯誤：6000 平方公尺以下者為 15 個以上，非 10 個以上。\n(D) 錯誤：10000 平方公尺以下者為 20 個以上，非 15 個以上。\n【記憶點】這是級距表不是比例公式：面積 1000、3000、6000、10000 平方公尺四級，對應 5、10、15、20 個，超過 10000 平方公尺才用每增加 5000 平方公尺加 5 個接續。","三十分鐘這個數字的來源在《各類場所消防安全設備設置標準》第 177 條：緊急照明設備應連接緊急電源，該緊急電源應使用蓄電池設備，其容量應能使其持續動作三十分鐘以上；但採蓄電池設備與緊急發電機併設方式時，其容量應能使其持續動作分別為十分鐘及三十分鐘以上。檢修基準的性能檢查就是去驗證這個容量，因此才需要抽查一定數量的燈具實測。同一節的判定方法還有另一組必背數值：照度以低照度測定用光電管照度計測試，於地下建築物之地下通道，緊急照明燈在地面之水平面照度應達十勒克斯（lux）以上，其他場所應達到二勒克斯（lux）以上。其餘性能檢查項目包括檢查開關（由檢查開關進行常用電源之切斷及復舊，切斷常用電源時應能自動切換至緊急電源即時亮燈，復舊時亦能自動切換回常用電源）、保險絲類（應無損傷或熔斷，且為規定之種類及容量）、結線接續（應無斷線、端子鬆動、脫落、損傷）與緊急電源（應無不亮燈或閃爍之情形）。應設場所依第 24 條，包含供第十二條第一款、第三款及第五款所列場所使用之居室、總樓地板面積在一千平方公尺以上建築物之居室（學校教室除外）、有效採光面積未達該居室樓地板面積百分之五者，以及自居室通達避難層所須經過之走廊、樓梯間、通道等平時依賴人工照明部分。容易與本題混淆的是同屬避難逃生設備的標示設備：出口標示燈及避難方向指示燈之緊急電源，依第 155 條容量應能使其有效動作二十分鐘以上，設於該條所列場所之主要避難路徑者則為六十分鐘以上。兩者各有條號與各自的分鐘數，記憶時要連設備名稱一起記。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-009","依據緊急廣播設備用揚聲器認可基準，有關頻率特性試驗，下列敘述何者錯誤？",9,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-011","依據火警探測器認可基準之構造及材質規定，下列敘述何者錯誤？",11,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-008","有關警報裝置設置場所之外觀試驗判定要領，依據瓦斯漏氣火警自動警報設備測試報告書，下列敘述何者錯誤？",8,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-012","有關出口標示燈及避難方向指示燈，在沒有不易看清或識別該燈情形的條件，依據各類場所消防安全設備設置標準，下列有效範圍何者錯誤？",12,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-007","有關揚聲器設置場所之外觀試驗判定要領，依據緊急廣播設備測試報告書，下列敘述何者錯誤？",7,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-013","有關避難器具設置規定，依據各類場所消防安全設備設置標準，下列何種避難器具不能裝置在使用場所之樑？",13,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-010",113,"下列場所設置的出口標示燈及非設於樓梯或坡道之避難方向指示燈，何者符合規定之要求？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-010",111,"依各類場所消防安全設備設置標準規定，有關揚聲器在居室樓地板面積在 X 平方公尺以下，其它非居室部分樓地板面積在 Y 平方公尺以下，且該區域與相鄰接區域揚聲器之水平距離相距 Z 公尺以下時，得免設。則 X、Y、Z 值，下列何者正確？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-010",110,"各型探測器在性能試驗中，下列有關其動作試驗的動作時間，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-010",109,"緩降機之設置應保有必要操作面積（不含避難器具所占面積），其相關規定下列何者正確？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-010",108,"某一廣播區域面積為 150 平方公尺，設有揚聲器，請問距所設揚聲器 1 m 處所測得之音壓須達多少以上才符合規定？",1785129963002]