[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-009":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-009","fire-112-1-alarm-evacuation-009",112,1,9,"依據緊急廣播設備用揚聲器認可基準，有關頻率特性試驗，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"揚聲器施加輸入電壓為輸入電力一瓦特（W）相當電壓，以額定電壓之正弦波掃瞄訊號為音源","揚聲器置於無響室或半無響室內，麥克風距離揚聲器 2 公尺處，量測其頻率特性","圓錐型揚聲器之額定頻率範圍上限值需達 8 千赫（kHz）以上，為功能正常","號角型揚聲器頻率區域之最高頻率範圍上限值需達 4 千赫（kHz）以上，為功能正常","B",null,[],false,"本題考點：《緊急廣播設備用揚聲器認可基準》頻率特性試驗的試驗條件，被動手腳的是麥克風與揚聲器之量測距離。\n【正解理由】依題目所據之《緊急廣播設備用揚聲器認可基準》頻率特性試驗，揚聲器置於無響室或半無響室內，麥克風應置於距揚聲器 1 公尺處量測其頻率特性。該認可基準之逐字規格應以中央主管機關公告內容為準，惟同體例之揚聲器音響量測規定均以一公尺為量測距離：《各類場所消防安全設備設置標準》第 133 條第一款為「距揚聲器一公尺處所測得之音壓」，《消防安全設備測試報告書測試方法及判定要領》緊急廣播設備之性能試驗亦為「於距離音響裝置中心 1 公尺之位置，使用噪音計（Ａ 特性）測定音壓」。選項所寫的 2 公尺與該基準所定之量測距離不符，故選 B。\n【逐項排除】\n(A) 與該基準相符：施加輸入電壓為輸入電力一瓦特（W）相當電壓，並以額定電壓之正弦波掃瞄訊號為音源。\n(B) 錯誤：量測時麥克風與揚聲器之距離為 1 公尺而非 2 公尺；至於置於無響室或半無響室之條件，則與規定相符。\n(C) 與該基準相符：圓錐型揚聲器之額定頻率範圍上限值需達 8 千赫（kHz）以上。\n(D) 與該基準相符：號角型揚聲器頻率區域之最高頻率範圍上限值需達 4 千赫（kHz）以上。\n【記憶點】揚聲器一律「站一公尺外量」：量音壓一公尺、量頻率特性也是一公尺，看到 2 公尺就是被改過的數字。","本題所據之《緊急廣播設備用揚聲器認可基準》為中央主管機關公告之認可基準，其逐字規格應以公告版本為準；以下改以相關法規中同一設備的規定作對照，說明各文件在量測距離上的一致性。認可基準、設置標準、檢修基準與測試報告書判定要領四者分工不同：認可基準管「產品出廠前的性能與構造」，例如揚聲器的頻率特性、輸入試驗；《各類場所消防安全設備設置標準》管「現場怎麼裝」，第 133 條第一款表定距揚聲器一公尺處之音壓為 Ｌ 級 92 分貝以上、Ｍ 級 87 分貝以上 92 分貝未滿、Ｓ 級 84 分貝以上 87 分貝未滿；《消防安全設備及必要檢修項目檢修基準》緊急廣播設備之綜合檢查管「定期檢修怎麼判」，載明距揚聲器一公尺處使用噪音計（Ａ 特性）確認音壓，判定為 Ｌ 級 92 分貝以上、Ｍ 級 87 分貝以上、Ｓ 級 84 分貝以上；《消防安全設備測試報告書測試方法及判定要領》緊急廣播設備之性能試驗則管「竣工查驗怎麼測」，在依額定輸出使音聲警報音之第二信號鳴動狀態下，於距離音響裝置中心 1 公尺之位置以噪音計測定，Ｌ 級應為 92dB 以上、Ｍ 級應為 87dB 以上、Ｓ 級應為 84dB 以上。四份文件在「一公尺」這個量測距離上完全一致，這正是本題把 1 公尺改成 2 公尺就露餡的原因。另一組易混淆概念是揚聲器型式：圓錐型（cone type）以振膜直接推動空氣，額定頻率範圍上限值需達 8 千赫以上；號角型（horn type）以號角導波、指向性強，其頻率區域之最高頻率範圍上限值需達 4 千赫以上，兩者各有其上限值，記數字時務必連型式一起記。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-008","有關警報裝置設置場所之外觀試驗判定要領，依據瓦斯漏氣火警自動警報設備測試報告書，下列敘述何者錯誤？",8,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-010","依據緊急照明設備檢修基準性能檢查之判定方法，有關檢查緊急電源容量能否持續 30 分鐘之檢查數量，下列敘述何者正確？",10,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-007","有關揚聲器設置場所之外觀試驗判定要領，依據緊急廣播設備測試報告書，下列敘述何者錯誤？",7,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-011","依據火警探測器認可基準之構造及材質規定，下列敘述何者錯誤？",11,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-006","有關室內排煙綜合試驗之排煙風量測試，依據排煙設備測試報告書判定要領，下列敘述何者錯誤？",6,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-012","有關出口標示燈及避難方向指示燈，在沒有不易看清或識別該燈情形的條件，依據各類場所消防安全設備設置標準，下列有效範圍何者錯誤？",12,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-009",113,"出口標示燈及避難方向指示燈之緊急電源應使用蓄電池設備，其容量應能使其有效動作 20 分鐘以上。但設於下列場所之主要避難路徑，該容量應在 60 分鐘以上，並得採蓄電池設備及緊急發電機併設方式，以下場所何者錯誤？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-009",111,"一非防火構造建築物，某層高度 5.2 公尺供辦公室使用，其探測區域為 310 平方公尺，若裝設補償式局限型 1 種探測器，最少設置數量應為多少個？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-009",110,"瓦斯漏氣火警自動警報設備之性能試驗中，下列有關串接配線試驗之測試及判定，何者與消防安全設備測試報告書測試方法及判定要領之規定不同？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-009",109,"有關避難方向指示燈裝設之敘述，下列何者錯誤？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-009",108,"緩降機固定架或支固器具使用錨定螺栓固定時，選用螺紋標稱為 M12×1.75 之螺栓，試問其螺栓埋入混凝土內不含灰漿部分之深度（mm）及轉矩值須為多少（kgf-cm）？",1785129962998]