[{"data":1,"prerenderedAt":73},["ShallowReactive",2],{"q-fire-112-1-alarm-evacuation-008":3},{"subject":4,"subjectSlug":5,"subjectKicker":6,"subjectShort":7,"question":8,"related":27,"sameNumber":52,"hasEssay":26},"警報與避難系統消防安全設備概要","alarm-evacuation","警報與避難 · Alarm & Egress","警報與避難系統",{"id":9,"webId":10,"year":11,"session":12,"subject":4,"number":13,"stem":14,"options":15,"answer":20,"answerNote":21,"images":22,"imagesPending":23,"lawTimestamp":11,"explanation":24,"explanationDeep":25,"freq":12,"indexable":26},"fire-112-1-警報與避難系統消防安全設備概要-008","fire-112-1-alarm-evacuation-008",112,1,8,"有關警報裝置設置場所之外觀試驗判定要領，依據瓦斯漏氣火警自動警報設備測試報告書，下列敘述何者錯誤？",{"A":16,"B":17,"C":18,"D":19},"擴音機應設置在受信總機之設置場所附近，且無妨礙操作之障礙物","揚聲器應設置在各樓，從該樓各部分至任一揚聲器之水平距離在 25 公尺以下的範圍內","瓦斯漏氣表示燈應設置距樓地板面之高度在 5 公尺以上","瓦斯漏氣表示燈應為黃色燈","C",null,[],false,"本題考點：瓦斯漏氣火警自動警報設備警報裝置之外觀試驗判定要領，關鍵在瓦斯漏氣表示燈的設置高度。\n【正解理由】依《消防安全設備測試報告書測試方法及判定要領》瓦斯漏氣火警自動警報設備之外觀試驗，瓦斯漏氣表示燈之判定要領為「距樓地板面之高度應在 4.5 公尺以下」；《各類場所消防安全設備設置標準》第 143 條第一款第二目亦明定「距樓地板面之高度，在四點五公尺以下」。選項將其寫成「5 公尺以上」，不僅數值不同，連上限與下限的方向都與規定相反，故選 C。\n【逐項排除】\n(A) 正確：音聲警報裝置之擴音機，應設置在受信總機之設置場所附近，且無妨礙操作之障礙物。\n(B) 正確：揚聲器應設置在各樓，從該樓各部分至任一揚聲器之水平距離在 25 公尺以下的範圍內。\n(C) 錯誤：瓦斯漏氣表示燈之設置高度為距樓地板面 4.5 公尺以下，並非 5 公尺以上；同條並要求其亮度在表示燈前方三公尺處能明確識別，掛得過高即失去識別功能。\n(D) 正確：判定要領明定瓦斯漏氣表示燈應為黃色燈。\n【記憶點】瓦斯漏氣表示燈三件事：黃色燈、距樓地板面四點五公尺以下、前方三公尺處能明確識別。","《各類場所消防安全設備設置標準》第 143 條把瓦斯漏氣之警報裝置分成兩款。第一款是瓦斯漏氣表示燈：設有檢知器之居室面向通路時，設於該面向通路部分之出入口附近；距樓地板面之高度在四點五公尺以下；亮度在表示燈前方三公尺處能明確識別，並於附近標明瓦斯漏氣表示燈字樣；但在一警報分區僅一室時，得免設之。第二款是檢知區域警報裝置：檢知器所能檢知瓦斯漏氣之區域內，該檢知器動作時，該區域內之檢知區域警報裝置能發出警報音響，其音壓在距一公尺處應有七十分貝以上；但檢知器具有發出警報功能者，或設於機械室等常時無人場所及瓦斯導管貫穿牆壁處者，不在此限。檢知器的設置高度則依瓦斯比重分流，《消防安全設備測試報告書測試方法及判定要領》瓦斯漏氣火警自動警報設備之外觀試驗載明：比重未滿 1 者，檢知器下端應設置在天花板等下方 0.3 公尺以內之位置，距離換氣口等出風口 1.5 公尺以上，距燃燒器或貫通部水平距離在 8 公尺以內；比重大於 1 者，檢知器上端應設置在地板上方 0.3 公尺以內之位置，距燃燒器或貫通部水平距離在 4 公尺以內。輕瓦斯往上積、重瓦斯往下沉，是這兩組數字唯一要記的邏輯。警報分區依第 140 條準用第 112 條劃定，該條並定義本設備所稱瓦斯為天然氣、液化石油氣及其他經中央主管機關指定者。緊急電源依第 145 條，應使用蓄電池設備，容量應能使二回路有效動作十分鐘以上，其他回路能監視十分鐘以上。易混淆的顏色考點：火警自動警報設備手動報警機旁的標示燈，判定要領載明燈光應為紅色；瓦斯漏氣表示燈則為黃色燈，兩者各有出處，不可互換。",true,[28,32,36,40,44,48],{"webId":29,"stem":30,"number":31,"year":11,"session":12},"fire-112-1-alarm-evacuation-007","有關揚聲器設置場所之外觀試驗判定要領，依據緊急廣播設備測試報告書，下列敘述何者錯誤？",7,{"webId":33,"stem":34,"number":35,"year":11,"session":12},"fire-112-1-alarm-evacuation-009","依據緊急廣播設備用揚聲器認可基準，有關頻率特性試驗，下列敘述何者錯誤？",9,{"webId":37,"stem":38,"number":39,"year":11,"session":12},"fire-112-1-alarm-evacuation-006","有關室內排煙綜合試驗之排煙風量測試，依據排煙設備測試報告書判定要領，下列敘述何者錯誤？",6,{"webId":41,"stem":42,"number":43,"year":11,"session":12},"fire-112-1-alarm-evacuation-010","依據緊急照明設備檢修基準性能檢查之判定方法，有關檢查緊急電源容量能否持續 30 分鐘之檢查數量，下列敘述何者正確？",10,{"webId":45,"stem":46,"number":47,"year":11,"session":12},"fire-112-1-alarm-evacuation-005","有關瓦斯漏氣檢知器一回路設置數量，依據瓦斯漏氣火警自動警報設備檢修基準之性能檢查，有關撰取檢查數量，下列敘述何者正確？",5,{"webId":49,"stem":50,"number":51,"year":11,"session":12},"fire-112-1-alarm-evacuation-011","依據火警探測器認可基準之構造及材質規定，下列敘述何者錯誤？",11,[53,57,61,65,69],{"webId":54,"year":55,"stem":56,"number":13},"fire-113-1-alarm-evacuation-008",113,"某醫學中心的 7 樓在考量避難器具選設的種類中，下列避難器具不適合？",{"webId":58,"year":59,"stem":60,"number":13},"fire-111-1-alarm-evacuation-008",111,"一場所設置定溫式局限型 1 種探測器（非再用型）共有 32 個，今進行動作試驗時，應抽取 X 個探測器以加熱試驗器加熱，測定至探測器動作時間為 Y 秒內合格，則 X、Y 為何？",{"webId":62,"year":63,"stem":64,"number":13},"fire-110-1-alarm-evacuation-008",110,"下列何組感知線型或分布型探測器在進行外觀試驗時，均須判定其感熱元件之極性有無誤接？",{"webId":66,"year":67,"stem":68,"number":13},"fire-109-1-alarm-evacuation-008",109,"緊急照明燈在地面之水平面照度，使用低照度測定用光電管照度計測得之值，在地下建築物之地下通道，其地板面應在 X 勒克司（Lux）以上，其他場所應在 Y 勒克司（Lux）以上。其中 X， Y 值為何？",{"webId":70,"year":71,"stem":72,"number":13},"fire-108-1-alarm-evacuation-008",108,"感熱式局限型探測器使用加熱試驗器對探測器加熱，依動作時間方法判斷，下列何者符合動作時間之規定？（標稱動作溫度與周圍溫度之差低於 50 度）",1785129962983]